Page 121
The below diagram illustrates the WRONG way to route your wiring and use the Y-cables. Sometimes people try to route everything through a panel or wiring closet – this will not work properly; it will generate excessive data noise and drag down the responsiveness of the Base and application. (With too much noise, the Base will stop working and issue a “Base Station Reinitalized” message to the terminals. If used, such a radial interface as below might appear to work most of the time, but it would be very sluggish and crash several times per day. Terminating or not terminating will be of no help. Do Not cable as below.
Incorrect Routing for Wiring
B-3
Page 122
Relay Station RS422 Pin-outs The R/F Relay Stations are connected by twisted pair wire -- use Belden 1227A1, Cat 5 wire, or equivalent. The Relay Port on the Base Station and the Relay Port on the Relay Station are connected with a straight cable using the following pin-outs: Base Connector Receive Data + Receive Data Transmit Data + Transmit Data -
Pin # 5 6 2 3
Relay Connector Transmit Data + Transmit Data Receive Data + Receive Data -
Make a cable with 5-5, 6-6, 2-2, and 3-3 (a straight cable); but, be careful that you select wires so that the 2 wire is in the twisted pair with the 3 wire, and the 5 wire is in the twisted pair with the 6 wire. For all RJ Cable pin numbers, number from left to right with the metal pin side of the connector facing you and the cable running to the down position
Relay Test Plan and Failures Relay Failure Relay Station failures are often cable-related. If a Terminal puts out a “Who Can Hear Me?” message and a Relay that is for some reason not connected to the Base Station (bad cable, cut cable, broken connectors) hears it, it answers with the message: Relay n Cannot Be Heard by the Base Notify Supervisor Press Any Key At this point, it is up to the operator to notify someone that the Relay is not communicating with the Base and to check the cabling first. There is no message sent to the host, so it is very important that the operator that receives this message notify someone immediately. Because relay cabling is often troublesome, we supply a test cable for isolating the user-made cable from the process. This test cable is so short that it doesn’t follow the rules of twists on the previous page – it is just a Ethernet patch cable for node, but adequate for testing the relay. HINT: Use the suggested wire type, and if you’re doing your own crimping, be sure to use the expensive metal crimpers ($100) and not the cheap plastic B-4
Page 123
crimpers ($15). Get someone familiar with making network (Ethernet) cables, but be sure to tell them not to use the Ethernet pin outs for the Relay Stations, (it has been tried more than once!).
Testing the Relay To test communication with a Relay, first check out the radio by doing a Site Test on the offending Relay with all other Relays and Bases OFF. To check if a Relay is working with a Base Station, set the Base to a different frequency than the Relay and set the Terminal frequency to match the Relay frequency. Be sure to set RELAY=YES on the Terminal Setup. Then cable -connect the Relay to the Base (RELAY port to RELAY port. Start your application on the host or use one of our demo programs provided with the Terminal (it’s a good way to test) - it takes 10 or more seconds for the Terminal to switch to the Relay. The delay is a result of the Terminal having to put out a "who can hear me" message when it doesn't get a response from the Base Station. The Relay responds to the Terminals "who can hear me" message and communication is established through the Relay. You will notice slightly slower throughput when working through the Relay.
Relay ID and Frequency… Relays should be set to the same frequency as the Base station and R/F Terminals that you will be using in your system. Determining the current frequency is the same as on the Base station; power up the Relay and count the number of times the LED flashes (frequency + 3). The default setting is Frequency 0 (3 flashes). Each Relay also requires a unique Relay ID; the default ID is 0. To change the Relay ID or frequency, you must open the Relay case.
B-5
Page 124
Changing the frequency on a Relay The Relay must have their frequency set to the same frequency as the R/F Terminals in their network. The frequency is set on a Relay by turning a rotary switch to the setting 0-F (16 different frequencies to choose from). Jumper JP103 should be set to Normal when making this change. Use a very small flat head screwdriver to turn the switch to the desired number.
Setting the Relay ID If you only have one relay, there is no need to set the Relay ID which is shipped default as relay 1. If you have multiple relays, each relay must have a unique ID, which is also set by turning the rotary switch, but is a little more complicated than setting the frequency: • Move Jumper JP103 to P (for Programming) • Move the Rotary Switch (SW1) to a position (0-F) to correspond to the ID to which you wish to set the Relay Station. • Now cycle power on the Relay Station. • Set JP103 back to N (for normal) and restore the Rotary Switch to the frequency setting on which you intend operate the Base Station and Terminals in the network.
B-6
Page 125
RS-422 Termination When adding Relays to a system, the last Relay(s) in the line(s) must be terminated. By default, all Base stations and Relay are shipped as terminated. Use the following guidelines to change the termination for your system: Refer to the circuit board diagram on the previous page for details. • If the Base has multiple strings of relays radiating from it, the Base would not be terminated but each Relay would. • If the Base is first in a string, (not in the middle or end of a string), set the 422 jumpers to Base w/RS-422 termination. • The last Relay in each string should have its jumpers set as a Relay w/RS-422 termination. Any Relay that is not the last relay in the string would not be terminated. Relay Station failures are often cable-related. If a Terminal puts out a “Who Can Hear Me?” message and a Relay that is for some reason not connected to the Base Station (bad cable, cut cable, broken connectors) hears it, it answers with the message: Relay n Cannot Be Heard by the Base Notify Supervisor Press Any Key At this point, it is up to the operator to notify someone that the Relay is not communicating with the Base and to check the cabling first. There is no message sent to the host, so it is very important that the operator that receives this message notify someone immediately.
B-7
Page 126
Page 127
Appendix C
R/F Serial Pin-outs Base Station to Host Pin-outs The Base Station is connected to a PC with one of the following cables:
F34 DB25 Null Modem Cable These are the pin-outs for Cable F34, a DB25 Female to 8 pin modular RJ45 with pins 2 and 3 crossed, used for a Base connected directly to a 25 pin male host serial port. Mod 8 RJ45
Function
DB25 Female
1 2 3 4
Frame Ground Transmit Data Receive Data Signal Ground
1 3 2 7
F34 Null Modem Cable * Modular Pins 5-8 are connected to DB25 pins 5,6,8,4 but not used by the R/F Base.
If you are planning to use a serial extension cable of 80 feet or more, you need to open the DB25 shell of our cable and be sure that only pins 1,3,2, and 7 are connected. All others should be cut. This is necessary to keep Windows from following noise transitions as handshaking transitions that can severely degrade the application or even crash Windows.
F36 DB9 Straight Cable These are the pin-outs for Cable F36, a DB9 Female to 8 pin modular RJ45. This cable is used to connect the Base to a 9 pin Male host serial port. Mod 8 RJ45
Function
DB 9 Female
Shell 1 2 3 4
(chassis ground)
Transmit Data Receive Data Signal Ground
Shell 2 3 5
F36 9 pin cable * Modular Pins 5-8 are connected to DB9 pins 8,6,4,7,but are not used by the R/F Base.
C-1
Page 128
If you are planning to use a serial extension cable of 80 feet or more, you need to open the DB9 shell of our cable and be sure that only pins 2,3 and 5 (plus the shell connection) are connected. All others should be cut. This is necessary to keep Windows from following noise transitions as handshaking transitions that can severely degrade the application or even crash Windows.
For all RJ Cable pin numbers, number from left to right with the metal pin side of the connector facing you and the cable running to the down position
Relay Station RS422 Pin-outs The R/F Relay Stations are connected by twisted pair wire -- use Belden 1227A1, Cat 5 wire or equivalent. The Relay Port on the Base Station and the Relay Port on the Relay Station are connected with a straight cable using the following pin-outs: Base Connector Receive Data + Receive Data Transmit Data + Transmit Data -
Pin # 5 6 2 3
Relay Connector Transmit Data + Transmit Data Receive Data + Receive Data -
Make a cable with 5-5, 6-6, 2-2, and 3-3 (a straight cable); but, be careful that you select wires so that the 2 wire is in the twisted pair with the 3 wire, and the 5 wire is in the twisted pair with the 6 wire. For all RJ Cable pin numbers, number from left to right with the metal pin side of the connector facing you and the cable running to the down position C-2
Page 129
Zebra Cameo/Encore Printers These are the pin-outs for the cable needed to connect the Zebra Cameo Printer to a Worth Data R/F Terminal. You can order our C12 cable for $30, or if you already have a cable from Zebra and feel confident in your cablemaking abilities, you can simply clip off the connector end that should connect to the RF Terminal (not the 8 pin din end) and replace the clipped-off connector with an RJ45 connector according to the pin-outs on the next page:
Cameo Connector
Function Receive Transmit CTS RTS Ground DSR DTR
RJ45 connector for RF Terminal
Printer 8 pin 1 2 3 4 5 7 8
RF Terminal RJ45 2 3 not connected 7 4 8 not connected
Function Transmit Receive none CTS Ground DTR none
Zebra Cameo - to - RF Terminal Pin-outs
Laser and CCD The laser and CCD TTL pin-outs are: Pin
Function
1 2 3 4 5 6 7 8
5 volts Data Phase LED Trigger Enable Shield(drain) Ground
Laser and CCD Pin-outs
Remember: If you make your own cables, you are on your own. We accept NO RESPONSIBILITY for damages resulting from incorrect wiring.
C-3