Page 81

Setup

Line Scan 1. From the Evaluation tab, click the Line Scan button. A window like that shown below will appear. 2. Drag your cursor horizontally across the image. This will create a dashed horizontal line. Pixel information and a visual representation of the dark and light pixels will be displayed below the image.

When you center your cursor over the dashed line, it becomes a double arrow cross. This allows you to move the line anywhere in the window. You can also use your keyboard arrows to move the line incrementally in any direction. As with the histogram, the line scan compares light and dark pixels, but in a spatial distribution. On the Y axis of the graph below, 0 is black and 255 is white; the X axis represents the horizontal axis of the symbol as described by the line scan. When you click anywhere on the graph, a vertical red line appears at that point and its position and value (in terms of black-to-white) are updated in the Pixel Info table to the left of the graph (237 in this example). In addition, a horizontal dashed red line is displayed that indicates the average value.

FIS-6801 Industrial Scanner User’s Manual

4-21

Page 82

Calibration

Calibration The Calibration interface in ESP is a powerful and intuitive way to optimize the imager’s performance. It allows the user to control several complex, simultaneous calibration operations, and to follow the progress of those operations using cues such as progress bars, real-time representations of calibration values, and other dynamic user feedback.

ESP’s Calibration interface shown during a calibration routine

4-22

ESP’s Calibration interface shown after a calibration routine

FIS-6801 Industrial Scanner User’s Manual

Page 83

Setup

Window of Interest The active pixel area of the image sensor is called the Window of Interest (WOI). The WOI allows the user to select an area of the field of view in which the desired symbol is located. The programmable window of interest increases decode speed, improves threshold, and makes it easy to select specific symbols from among several in the field of view. The user provides the upper-left pixel location and the size of the window to define the Window of Interest.

Window of Interest (CMOS) Caution: Window of Interest will shrink the field of view and therefore could cause symbols to be missed in dynamic applications.

FIS-6801 Industrial Scanner User’s Manual

4-23

Page 84

Window of Interest

Window of Interest Graphic Interface 1. From the Camera menu, click the WOI tab to bring up Window of Interest. If you haven’t already captured an image, click the Capture and Decode button to decode the present image. If successful, the Good Read indicator on the WOI tab will be green and the symbol will appear in the pane below. Note: You can resize the image by clicking and dragging the ESP window from the lower right corner. This is useful where very small symbols are being read. 2. Click and drag your cursor over the symbol that you want to isolate for reading. Notice that the surrounding area goes black. You can use the handles on the image area that you have just drawn to resize the region of interest. You can also click on the center of the window of interest and move it. 3. Test the new settings in Read Rate Mode.

Note: To remove the window of interest, click the Reset button or click anywhere in the WOI pane. Note that all pixels not in the WOI are defined as black. Because the imager has far less processing to do in a smaller window, read rates typically increase dramatically. One possible downside is that the chance of missing a symbol increases with the smaller window. Always verify that your WOI will be large enough to allow for any random movement of symbols in your field of view. 4-24

FIS-6801 Industrial Scanner User’s Manual

Page 85

Setup

Configuration Database The Configuration Database allows the user to manage multiple configuration profiles. It is a useful tool in applications that require several different imager configurations to be applied sequentially, and it allows the user to perform far more complex operations than would be possible with only one set of configuration parameters.

Configuration Database view, CMOS, set for 5 Active Indexes, with Capture Settings highlighted As soon as the number of active database settings is something other than 0, the database is enabled. Once enabled, the current configuration settings (that are handled by the database) have no impact on imager operation.

Capture Index Each index in the database (1 – 10) can be configured and tested individually.

FIS-6801 Industrial Scanner User’s Manual

4-25

Page 86

Configuration Database

Shutter Speed Sets the camera’s shutter speed (60 – 40,000, default 2,500) for the selected index.

Gain (CMOS) Sets the camera’s gain (0 – 33, default 20) for the selected index.

Focal Distance Sets the camera’s focal distance (25 – 4,000, default 80) for the selected index.

Sub-Sampling Sets the sub-sampling rate (4:1 or 16:1, Disabled by default) for the selected index. Important: Sub-Sampling has no effect when the “Image Dimension” mode is configured as Region of Interest in the Database Mode command. This is because the camera Window of Interest is determined by the software based on the database ROI setup and there is no benefit to sub-sampling to increase speed, as the frame size would have to be increased to account for the sub-sampling.

Top/Left/Height/Width The image dimension settings can be applied as a Window of Interest or a Region of Interest depending on the image dimension mode selected in the Database Mode command. Top: 0 to (480 – height) Default: 0 Left: 0 to (752 – width) Default: 0 Height: 3 to (480 – top) Default: 480 Width: 8 to (752 – left) Default: 752

Symbol Type This field allows the user to configure the database to operate on specific symbol types for selected database index. Symbol type-specific parameters must be configured with the appropriate symbol type command. For example fixed length Code 128 is required; it must be set up with the Code 128 command <K474>. To configure a symbol type, simply add the number value associated with the symbol type to the field parameter. Example: If Data Matrix and Code 39 are required the parameter would be 2 + 16 = 18.

Disabled When disabled, the database uses the current Symbol Type setup to determine active symbol types.

4-26

FIS-6801 Industrial Scanner User’s Manual

Page 87

Setup

Any Type All of the preceding symbol types, except Pharmacode, are enabled while this database index is being used. <K255>: Add 1.

Data Matrix If enabled, Data Matrix will be active for this database index. Important: The ECC Level must be configured using the Data Matrix command <K479>. If no ECC level has been configured, then it will not decode a Data Matrix symbol. <K255>: Add 2.

QR Code If enabled, QR Code will be active for this database index. <K255>: Add 4.Code 128 If enabled, Code 128 will be active for this database index. <K255>: Add 8.

Code 39 If enabled, Code 39 will be active for this database index. <K255>: Add 16.

Codabar If enabled, Codabar will be active for this database index. <K255>: Add 32.

Code 93 If enabled, Code 93 will be active for this database index. <K255>: Add 64.

Interleaved 2of 5 If enabled, Interleaved 2of 5 will be active for this database index. <K255>: Add 128.

UPC If enabled, UPC will be active for this database index. <K255>: Add 256. FIS-6801 Industrial Scanner User’s Manual

4-27

Page 88

Configuration Database

PDF417 If enabled, PDF417 will be active for this database index. <K255>: Add 512.

MicroPDF417 If enabled, MicroPDF417 will be active for this database index. <K255>: Add 1024.

BC412 If enabled, BC412 will be active for this database index. <K255>: Add 2048.

Pharmacode If enabled, Pharmacode will be active for this database index. <K255>: Add 4096.

DataBar-14 If enabled, DataBar-14 will be active for this database index. <K255>: Add 8192.

DataBar Limited If enabled, DataBar Limited will be active for this database index. <K255>: Add 16384.

DataBar Expanded If enabled, DataBar Expanded will be active for this database index. <K255>: Add 32768.

Micro QR Code If enabled, Micro QR Code will be active for this database index. <K255>: Add 65536.

Aztec If enabled, Aztec will be active for this database index. <K255>: Add 131072. 4-28

FIS-6801 Industrial Scanner User’s Manual

Page 89

Setup

Current Postal Symbology If enabled, Current Postal Symbology will be active for this database index. <K255>: Add 262144.Morphology Operation Allows the user to select the method for processing captured images. Parameter values for serial command <K255>: 0 – Disable 1 – Erode 2 – Dilate 3 – Open 4 – Close

Morphology Size Determines the size of the area or “pixel neighborhood” (measured in pixels) in which the morphological operation is being performed. Parameter values for serial command <K255>: 3 – Small (3 pixels by 3 pixels) 5 – Medium (5 pixels by 5 pixels) 7 – Large (7 pixels by 7 pixels)

FIS-6801 Industrial Scanner User’s Manual

4-29

Page 90

Configuration Database

Database and Capture Modes The configuration database behaves the same for both “Rapid” and “Continuous” Capture Mode, the only discernable difference is in “Rapid” capture mode the database incrementing always operates in “Number of Image Frames” with a “frame count” of 1.

Camera Settings When the database loads a camera configuration and there is a change in shutter speed (integration time), window of interest (WOI), or sub-sampling from the last image that was captured; Then one image frame needs to be processed to setup the new configuration prior to capturing an image. The capture will start immediately following the integration period. If the image dimensions are configured as a Region of Interest (ROI), then a change to these values does not incur the additional image frame since it is no longer a camera setting. Since some image capture events require that an image frame delay occur and some don’t, this does complicate the image capture time when the Configuration Database is enabled. Notes: • If no camera change occurs, the start of the image capture is immediate upon being triggered • If a camera change occurs, the start of the image capture occurs after the shutter time has completed. In the case above, the image capture would incur a 1ms delay.

Number of Active Indexes Number of database records (groups of settings) that will be used automatically during the read cycle. If set to 0, the imager only uses the current settings, not database entry settings.

Sort Database Activates a sort function that move the database entry associated with the last decode to the first position in the database and move all other entries up.

4-30

FIS-6801 Industrial Scanner User’s Manual