Page 91
Setup
Database Mode Switch Mode Selects the event that causes the imager to load the next entry from the database to current, active settings. When timer/count expires and “Image Process Looping” is enabled the next database entry that has a camera modification will be used. Notes: Capture event always occurs when the 1st database entry is used. This setting has no effect in Rapid Capture mode. Rapid Capture mode always operates in “Number of Frames” mode, with a “Frame Count” = 1.
Time The imager will load the next entry from the database to current after a defined time interval. The timer will start upon use of a database entry. In other words, if the timer expires during a capture event, the timer will not start again until the database entry has been incremented and the new entry has been loaded to current.
Number of Image Frames Database index is incremented after the specified number of image frames have been captured.
Frame Count/Time Indicates the “Number of Frames” that will occur or the amount of “Time” that is required before the imager will load the next database configuration. Timer resolution is 1ms.
Image Process Looping This feature is useful for processing a captured image frame multiple times with different Image Process/Decode parameters.
Disabled An image is captured for every database configuration, regardless if a camera setting has been modified.
Enabled When a database configuration is loaded to current, and the Camera settings have not changed from last capture event, a new image is not captured. But rather the last image frame that was captured is re-processed with the new Image Processing/Decode configuration. The one exception is with the 1st database index, a new image is always captured when the 1st database configuration is used. When a camera setting has been modified from one database setting to the next, a new image is captured. For example, if all database entries contained the same camera setting values, but had different IP/Decode configurations, the only time an image frame would be captured would be when the 1st database configuration was used. FIS-6801 Industrial Scanner User’s Manual
4-31
Page 92
Configuration Database
Image Dimensions This feature defines how the image dimension parameters are implemented.
Window of Interest (WOI) In this mode the database image dimension parameters are Camera Settings and dictate the size of the image to be captured.
Region of Interest (ROI) In this mode the database image dimension parameters are Image Processing\Decode Settings and specify the region or area of the captured image to be processed. The ROI coordinate data is based on the full scale image size. The WOI of the captured image will be configured to cover all the active database ROI settings. In the following example there are three active database setting, with different ROI configurations. Their coordinates are based at point 0,0 of the full scale image (SXGA = 1280 x 1024 or VGA = 640 X 480). The image WOI is not configurable, it is automatically setup by the database, based on the ROI settings. This feature is intended to be used in conjunction with the “Image Process Looping” feature, to allow processing different regions of a captured image with different Image Processing Decode Settings. In addition, if combined with “Output Filtering” the user can order the output of decoded symbols in a captured image frame by their location in the Field of View.
Multiple Symbols with Same Symbol Data Operation ROI can be used to decode more than one of the same symbols and treat them as different symbols. Multi Symbol Operation will work within the following rules: • Multiple symbols of same symbol data can only be handled by using ROI mode. This can only be done between different ROI IP Region settings. • ROI IP Region settings within the database must be sequential (Not Interlaced) in order to correctly know when a new region has been tried. If Database slot 2 and 3 are swapped, the imager would then treat them as 4 separate ROI regions. This would result in 4 different symbols with GDR of 1 instead of 2 different symbols with GDR count of 2. • ROI Regions will count the same symbol in the same region as additional decodes, but only spanning multiple frames. Each decode of same symbol with same ROI will add to the GDR count with additional frames. • Multiple symbols can be within each ROI Region but cannot identify multiple Same Symbols. If same symbol is in a ROI twice per frame then it will be counted as 1 decode or 1 more GDR count, the second will be ignored. • Filtering can only be done with database # because all other data is same.
4-32
FIS-6801 Industrial Scanner User’s Manual
Page 93
Setup
Ordered Output Output filtering is a method of providing a set of good read qualifiers and also providing ordered output. There is a filter for up to the first 10 positions in a multisymbol output. The first filter corresponds to the first symbol output at the end of the read cycle. Each filter has settings for the following six parameters: Filter Number, Symbology Type, Length, Wildcard, Placeholder, Matching Data, Decode Direction, and Database Number. Filter Number, Symbology Type, Length, Wildcard, Placeholder, and Matching Data are all displayed in the table below. Double-clicking on any row of the table will display the Ordered Output Filter Settings dialog, where settings can be changed.
Receive settings from the imager, Send settings to the imager, or Send and Save settings.
Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable output filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 5, then filter indexes 1, 2, 3, 4, and 5 will be applied.
FIS-6801 Industrial Scanner User’s Manual
4-33
Page 94
Ordered Output
Filter Number This is the filter index number that represents the position of the symbol in the data output at the end of the read cycle. This index number should be entered along with the following filter settings for the predetermined symbol position.
Symbology Type Specifies the symbology type allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all the requirements of the selected filter index.
Length Specifies the length of the decoded symbol allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.
Wildcard This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.
Placeholder The placeholder character requires a character to be present, but does not compare the data value.
Matching Data This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”. 4-34
FIS-6801 Industrial Scanner User’s Manual
Page 95
Setup
Ordered Output Filter Settings
Double-clicking on a row in the Ordered Output table brings up the Ordered Output Filter Settings dialog. Use these settings to determine Symbology Type, Length of the symbol, a user-defined Matching String, ASCII Lookup, Wildcard Character, Placeholder Character, Database Number, and Decode Direction. Click Apply to save the settings to the corresponding filter.
FIS-6801 Industrial Scanner User’s Manual
4-35
Page 96
Ordered Output
Rules for Output Filter Configuration Output Filter Configuration Rule # 1 Each symbol that is decoded must match one of the filters before it can be saved to a read cycle record. There is an exception to this rule, however, when the number of symbols required for a read cycle exceeds the number of active filters. In such a case, unfiltered symbols can be placed into unfiltered output positions. For example, if the number of symbols required is 6 but there are only 5 active filters, the last position can be filled by any (unfiltered) qualified symbol.
Output Filter Configuration Rule # 2 The same filter setup can be used multiple times. For example, filters 1, 2, and 3 can be set up to filter Code 39 symbols, and the output will occur in the order the symbols are decoded.
Output Filter Configuration Rule # 3 All qualified symbols will be sorted and output in the matching filter position. If a symbol matches filter 3, it will be output as the third symbol. If a filter does not have a matching qualified symbol, a No Read message will be output in place of the symbol (assuming the No Read message is enabled). For example, if there is not a symbol that meets filter 3’s requirements, then a No Read message will be output in the third output position.
4-36
FIS-6801 Industrial Scanner User’s Manual
Page 97
Setup
Output Format Enable Output Format This is a global enable/disable parameter. Use Set Number of Symbols and Output Phrase to assign symbols for formatting, and Symbol Parse to determine the specific output content for the assigned symbols. On the Output Format tab, check the Enable Output Format box.
FIS-6801 Industrial Scanner User’s Manual
4-37
Page 98
Output Format
Set Number of Symbols Number of Symbols determines the number of symbols to which output formatting will apply.
Output Phrase Output Phrase refers to the user-defined Preamble, selected symbols, and Postamble sequence in the read cycle result. Use the Set Number of Symbols spin box to determine the number of symbols to be included in the output phrase.
Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.
4-38
Check the Parse boxes beneath the symbols to be formatted.
Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.
FIS-6801 Industrial Scanner User’s Manual
Page 99
Setup
Symbol Parse Extract
The Extract Range function corresponds to the Start Location and Length parameters in the Format Extract serial command.
Multiple character sequences can be extracted and inserted using Symbol Parse. In this example, the selected extraction range is characters 2-4. The “Sample Symbol” example on the Symbol Parse dialog shows the selected character positions extracted and output as desired. Simultaneously, the data string from the selected symbol is displayed at the bottom left of the Parse Table, followed by the user-defined extracted output.
FIS-6801 Industrial Scanner User’s Manual
4-39
Page 100
Output Format
Insert
4-40
FIS-6801 Industrial Scanner User’s Manual