Page 101
Setup
The Insert process is very similar to the Extract process, except that Insert allows the user to enter characters using the Insert calculator (shown above).
Notice that Extract and Insert share the same Parse Table.
FIS-6801 Industrial Scanner User’s Manual
4-41
Page 102
Dynamic Setup
Dynamic Setup Dynamic Setup is used to calculate image capture timing during a read cycle. Without proper timing, the imager will not be able to decode all symbols in a read cycle. An external trigger is used to activate image captures so the user can make timing adjustments as capture events occur.
Read Rate is represented graphically in real-time as the user makes adjustments to the time delay between image captures. The user can control Capture #, Number of Captures, and Number of Symbols using these spin boxes.
The Delay Adjustment slider allows the user extremely precise control of the time delays between image captures in a read cycle. Delay values are shown in seconds in the field above the slider. The Coarse and Fine Delay Adjustment options determine whether larger or smaller adjustment increments will be used.
4-42
FIS-6801 Industrial Scanner User’s Manual
Page 103
5 Parameters Contents Communication ............................................................................................................................. 5-2 Read Cycle ................................................................................................................................. 5-41 Symbologies ............................................................................................................................... 5-61 I/O Parameters............................................................................................................................ 5-97 Symbol Quality.......................................................................................................................... 5-159 Matchcode ................................................................................................................................ 5-166 Diagnostics ............................................................................................................................... 5-175
This section explains the function and purpose of the Parameters commands in ESP’s tabbed tree controls. Important: Unless otherwise specified, command settings shown in this section are the default settings.
FIS-6801 Industrial Scanner User’s Manual
5-1
Page 104
Communication
Communication Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Communication tab to display the Communication tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Communication settings can also be sent to the Scanner from ESP’s Terminal using wenglor’s K command format. Refer to the Communication section of Appendix E.
5-2
FIS-6801 Industrial Scanner User’s Manual
Page 105
Parameters
Port Routing The FIS-6801 features a communication system based on Port Routing instead of traditional, dedicated serial ports. Decisions can be made about the direction and content of communication between ports based on different Data Types. Any available port can be used in any combination. The fundamental concept of Port Routing is that communication design can be based upon Data Types rather than ports. The advantage of this is the ability to map different data types to different ports - the user is no longer limited to a “Host Port” and “Aux Port” for specific types of input and output. Since each port is independent instead of fixed for a particular purpose, the Scanner behaves more like a data switch.
Standard FIS-6801
FIS-6801 Industrial Scanner User’s Manual
5-3
Page 106
Communication
Port Routing Advantages • Data can be routed in on one port and out on the same port or a different port like a switch or router. Transparent Mode, Half Duplex Mode, Full Duplex Mode, and Custom Mode. • External Data Routing still follows the “To/From Host/Aux” paradigm. The new capability allows the customer to define the data direction - which port behaves as the “Host Port” and which port behaves as the “Aux Port”. • Only one daisy chain setup required per system. • Minimal configuration required for each port, with similar items grouped together.
5-4
FIS-6801 Industrial Scanner User’s Manual
Page 107
Parameters
RS-232 A The following settings define the basic transmission speeds and digital standards that ensure common RS-232 formatting.
Baud Rate Can be used to transfer data faster or to match host port settings. The rate at which the Scanner and host transfer data back and forth.
Parity Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd.
Stop Bits Only changed if necessary to match host setting.
FIS-6801 Industrial Scanner User’s Manual
5-5
Page 108
Communication One or two bits added to the end of each character to indicate the end of the character.
5-6
FIS-6801 Industrial Scanner User’s Manual
Page 109
Parameters
Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
Symbol Data Output Enables or disables decoded symbol data output from the Scanner.
Extra Symbol Information Enables or disables extra symbol information output from the Scanner.
Diagnostics Output Enables or disables diagnostics output from the Scanner.
FIS-6801 Industrial Scanner User’s Manual
5-7
Page 110
Communication
External Source Processing Mode Enables or disables processing of commands or data from sources external to the Scanner.
Command Command enables command processing in the Scanner. Note: Command processing is always enabled for RS-232 A.
Data Data enables RS-232 A as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
5-8