Page 71

Setup

Sub-Sampling The camera can be enabled to sub-sample pixels in the specified image frame. Sub-sampling can be specified as either 4:1 or 16:1, which signifies the sampling rate. Note: Sub-Sampling is not available for the CCD model of the FIS-6801.

4:1 1 pixel output for every 4 pixels sampled. When selected the image will be sampled 2:1 in the vertical direction and 2:1 in the horizontal direction for a combined 4:1 ratio. An image with a dimension of 640 x 480 will be scaled to 320 x 240.

16:1 1 pixel output for every 16 pixels sampled. When selected the image will be sampled 4:1 in the vertical direction and 4:1 in the horizontal direction for a combined 16:1 ratio. An image with a dimension of 640 x 480 will be scaled to 160 x 120.

FIS-6801 Industrial Scanner User’s Manual

4-11

Page 72

Camera Setup

CMOS (WVGA) Window of Interest

The active pixel area of the image sensor is defined as the “Window of Interest” (WOI). This allows the user to select an area in the Field of View that the desired symbol will be located. The programmable window of interest is useful for increasing decode speed, improving threshold, selecting desired symbol from multiple symbols in FOV. The user provides the upper-left pixel location and the size in both rows and columns to define the Window of Interest.

Important Notes: • The column width value is required to be a modulus 32 value, so regardless of the column width setting that is configured the actual column width will be decreased (if required) to a modulus 32 value. For example a column width value of 632 would actually be 608. A user request of this setting would still return 632. • The column pointer is required to be an even value, so regardless of the column pointer setting that is configured the actual column pointer will be decreased (if required) to an even value. For example a column pointer value of 101 would actually be 100. A user request of this setting would still return 101.

Top Defines the row position of the upper-left starting point of the image window.

Left Defines the column position of the upper-left starting point of the image window.

4-12

FIS-6801 Industrial Scanner User’s Manual

Page 73

Setup

Height Defines the size, in rows, of the image window. Maximum value is defined as the Maximum row size of Image sensor, minus the row pointer value.

Width Defines the size, in columns, of the image window. Maximum value is defined as the Maximum column size of Image sensor, minus the column pointer value.

FIS-6801 Industrial Scanner User’s Manual

4-13

Page 74

Camera Setup

CCD (SXGA) Window of Interest

The active pixel area of the image sensor is defined as the “Window of Interest” (WOI). This allows the user to select an area in the Field of View that the desired symbol will be located. The programmable window of interest is useful for increasing decode speed, improving threshold, selecting desired symbol from multiple symbols in FOV. The user provides the upper-left pixel location and the size in both rows and columns to define the Window of Interest.

Important Notes: • The column width value is required to be a modulus 32 value, so regardless of the column width setting that is configured the actual column width will be decreased (if required) to a modulus 32 value. For example a column width value of 632 would actually be 608. A user request of this setting would still return 632. • The column pointer is required to be an even value, so regardless of the column pointer setting that is configured the actual column pointer will be decreased (if required) to an even value. For example a column pointer value of 101 would actually be 100. A user request of this setting would still return 101.

Top Defines the row position of the upper-left starting point of the image window. An Increase in this value will cause an increase in frame rate at a resolution of 46 microseconds (row period). If this value is changed and the resulting combination of row pointer plus row depth exceeds the maximum allowed, the row depth will be decreased to an acceptable value.

Left Defines the column position of the upper-left starting point of the image window. If this value is changed and the resulting combination of column pointer plus column width exceeds the maximum allowed, the column width will be decreased to an acceptable value.

4-14

FIS-6801 Industrial Scanner User’s Manual

Page 75

Setup

Height Defines the size, in rows, of the image window. Maximum value is defined as the Maximum row size of Image sensor, minus the row pointer value. A decrease in this value, coupled with an increase in the row pointer value, will cause an increase in frame rate at a resolution of 46 microseconds (row period).

Width Defines the size, in columns, of the image window. Maximum value is defined as the Maximum column size of Image sensor, minus the column pointer value. Changing this parameter will have no effect on frame rate.

FIS-6801 Industrial Scanner User’s Manual

4-15

Page 76

Camera Setup

Image Processing Settings Image Processing Timeout See Image Processing Timeout in Read Cycle.

Capture Mode See Capture Mode in Read Cycle.

Morphological Pre-Processing Morphological Pre-Processing allows the user to select the method for processing images, and to choose the operator size for that method. Important: This command must be set to Enabled for Morphological Operation to function.

Morphological Operation and Operator Size Operation Morphological Operation allows the user to select the method for processing captured images.

Erode Erode increases the dark cell size of a symbol. Useful for increasing the dark cell size of a dark-on-light Data Matrix symbol.

Dilate Dilate increases the light cell size of a symbol. Useful for increasing the light cell size of a

4-16

FIS-6801 Industrial Scanner User’s Manual

Page 77

Setup light-on-dark Data Matrix symbol.

FIS-6801 Industrial Scanner User’s Manual

4-17

Page 78

Camera Setup Open Open removes minor light defects of dark cells by performing a Dilate function followed by an Erode function.

Close Close removed minor dark defects of light cells by performing an Erode function followed by a Dilate function.

Operator Size Operator Size determines the size of the area or “pixel neighborhood” (measured in pixels) in which the morphological operation is being performed.

Small (3 pixels by 3 pixels) Medium (5 pixels by 5 pixels) Large (7 pixels by 7 pixels)

4-18

FIS-6801 Industrial Scanner User’s Manual

Page 79

Setup

Evaluation In Evaluation, you can view images currently in the imager, capture and decode a symbol, save it as a digital file, and perform histogram and line scan evaluations. When you click on the Evaluation tab, you will see the images that are currently stored in the imager. Click Receive to refresh this view. Click Capture/Decode to display the and decode event will occur, regardless of read cycle settings. Click Read to trigger a read cycle. If there is enough time in the read cycle, up to 32 good reads (or 6 full-scale images) can be captured and displayed, depending on the size of the images, and depending on the number enabled in Number of Captures under Capture Mode in the Camera Setup menu tree to the left of the tabs. If you click Save, the current image will be saved to the location of your choice. Note: An image can only be saved in the format in which it was uploaded to ESP. JPEG images will be saved as .jpg, and bitmaps will be saved as .bmp. When you click the JPEG Image box, notice that the Line Scan button is grayed out. The JPEG option allows faster captures and transfers, but since the JPEG standard compresses image data, it is not suitable for the more rigorous demands of line scan evaluation. JPEG also allows you to adjust the image quality (resolution) by adjusting the sliding tab between 1 and 100, 1 being the lowest quality and 100 being the highest. When possible, use the highest quality; when image transfer speed must be increased, use a lower image quality setting. Adjustments for this setting will depend on your specific hardware and software limitations.

FIS-6801 Industrial Scanner User’s Manual

4-19

Page 80

Evaluation

Histogram The Histogram function is useful in determining quality and contrast of symbols. A histogram is a graphic representation of the numeric count of the occurrence of each intensity (gray level) in an image. The horizontal axis represents the values of gray levels, and the vertical axis represents the number of pixels for each gray level. Note: Since histograms are performed in the imager, the results will be saved regardless of whether the image was uploaded as a JPEG (.jpg) or a bitmap (.bmp). 1. From the Evaluation window, click the Histogram button. The current image is transferred into the histogram operation. This may take a moment, since all the relevant pixels are being evaluated intensively. 2. When the Histogram window opens, you may need to expand the window and/or adjust the scroll bars in order to bring the image into view. 3. To generate a histogram, click and drag your cursor diagonally across the symbol or a portion of the symbol. The image will be surrounded by an “area of interest box”, a dashed blue line with red anchor points that can be selected and moved by placing a cursor inside the box, and can be resized by clicking and dragging the anchor points.

4-20