Page 61

4 Setup Contents Video............................................................................................................................................. 4-2 Evaluation ................................................................................................................................... 4-18 Calibration................................................................................................................................... 4-21 Window of Interest ...................................................................................................................... 4-22 Configuration Database .............................................................................................................. 4-24 Ordered Output........................................................................................................................... 4-33 Output Format............................................................................................................................. 4-37 Dynamic Setup ........................................................................................................................... 4-41

This section describes ESP’s Setup interfaces: Video, Evaluation, Calibration, Window of Interest, Configuration Database, Ordered Output, Output Format, and Dynamic Setup. Each interface allows the user to make changes to imager configuration quickly and easily.

FIS-6801 Industrial Scanner User’s Manual

4-1

Page 62

Video

Video The Video view allows the user to perform the same Locate, Calibrate, and Test routines. There is also a focal distance adjustment tool to the right of the video view. Video also features simple Capture and Decode functionality.

4-2

FIS-6801 Industrial Scanner User’s Manual

Page 63

Setup

Learn The Learn command, located in ESP’s EZ Mode and in the Setup section on the Video tab, puts the FIS-6801 into a mode of operation that will cause it to “learn” the next Data Matrix symbol decoded. Learn Mode remains active until either a Data Matrix symbol is decoded or Learn Mode is disabled by re-clicking the Learn button. Upon decoding a Data Matrix symbol, the FIS-6801’s image processing will save pertinent information about the learned symbol so that subsequent identical symbols will be processed more quickly. See Learn Operations in Utilities for other Learn commands that can be sent serially. Click the Learn button to start Data Matrix Learn Mode.

The Learn button will say “Learning” during the learn operation.

The Learn button will say “Learned” when the Data Matrix symbol has been learned.

The learn state and parameters persist in the same way as ordinary parameters. Examples: • A FIS-6801 in a Learned state has not been saved. Cycling power will remove any Learned state information and the imager will power-on in its configured state. • A FIS-6801 is saved in a Learning state. The imager will power-on in the Learning state and will learn the first Data Matrix symbol decoded. • A FIS-6801 is saved in a Learned state. The imager will power-on in the Learned state and will only decode the learned symbol type. • A FIS-6801 in a Learned state is issued a reset default command <Ard>. The unit will return to an Unlearned state but if power is cycled it will return to its saved state. FIS-6801 Industrial Scanner User’s Manual

4-3

Page 64

Video

Select Lens (Standard FIS-6801 Only) This value must reflect the correct camera lens currently installed on the product. This value is configured after leaving the factory. However, since the lens can be changed by the user, this parameter needs to be updated to reflect the currently installed lens. Click the Select Lens button on the Video tab. To verify lens type, turn off power to the FIS-6801 (do not look into the targeting laser). Then look at the outer rim of the unit’s camera lens. The following markings define the correct “Lens Type” parameter value: ‘.’, and “15” = Lens Type 1 ‘..’, and “30” = Lens Type 2 ‘...’, and “45” = Lens Type 3 When a lens is changed on the FIS-6801, the user can optimize the accuracy of the Focal Distance parameter by using the <@OPTIC> command. Important: <@OPTIC> is not supported by the FIS-6801 C-Mount Imager. This parameter is “sticky”. Once saved with a <Z> or <Zc> command, it can only be “defaulted” with <Zrdall> or <K525d>.

15 Degree Lens

30 Degree Lens

45 Degree Lens 4-4

FIS-6801 Industrial Scanner User’s Manual

Page 65

Setup

Camera Setup Click the App Mode button and then the Setup button. You will see the Camera Setup tree control to the right of the Video interface.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Communication settings can also be sent to the imager from ESP’s Terminal using wenglor’s K command format.

FIS-6801 Industrial Scanner User’s Manual

4-5

Page 66

Camera Setup

CMOS (WVGA) Camera Settings

Gain Sets the gain value for the image sensor. This setting can be configured through autocalibration, and is the recommended method for configuring this settings. A higher value will increase the brightness of the image, but the noise performance of the system is reduced. Prior to configuring the gain, the required shutter speed should be set, and the gain should be configured to optimize the shutter speed setting.

Shutter Speed This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If an object is moving fast and a slow shutter speed is selected, blurring or smearing of the object will occur. As shutter speed is increased the amount of light required or gain needed has to be increased since the pixels exposure time has decreased.

4-6

FIS-6801 Industrial Scanner User’s Manual

Page 67

Setup

CCD (SXGA) Camera Settings

Gain Sets the gain value for the image sensor. This setting can be configured through autocalibration, and is the recommended method for configuring this settings. A higher value will increase the brightness of the image, but the noise performance of the system is reduced. Prior to configuring the gain, the required shutter speed should be set, and the gain should be configured to optimize the shutter speed setting.

Shutter Speed This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If an object is moving fast and a slow shutter speed is selected, blurring or smearing of the object will occur. As shutter speed is increased the amount of light required or gain needed has to be increased since the pixels exposure time has decreased.

FIS-6801 Industrial Scanner User’s Manual

4-7

Page 68

Camera Setup

Illumination Type (Standard FIS-6801 Only) Mode Configures the illumination pattern. “Bright Field” is used for most applications. For Mode 4, the internal illumination is always off, similar to configuration setting 0 (Always Off).

Bright Field

Mode 2

Mode 3

Mode 4 (Internal LEDs Off)

Brightness Configures the amount of illumination output from the unit’s built-in lighting.

4-8

FIS-6801 Industrial Scanner User’s Manual

Page 69

Setup

External Smart Light (FIS-6801 C-Mount Only)

Disabled When External Smart Light is set to Disabled, the external smart light control is disabled and Output 3 is available for any other operation.

Always On When External Smart Light is set to Always On, the external smart light is continuously on.

Always Off When External Smart Light is set to Always Off, the external smart light is continuously off.

On Only When in Read Cycle When External Smart Light is set to On Only When in Read Cycle, the external smart light will be on when the imager is in an active read cycle. Important Note: The external smart light's active state is controlled through the Output State of Output 3, which is used as the external control line. To control the external light using a wenglor standard 12-pin-to-5-pin external light control cable, set Output 3's Output State to Normally Closed and Output Common to ground. Any other settings that relate to Output 3, such as Output 3 Diagnostics will be ignored if this mode is enabled. The external light will be continuously on until the system is fully re-booted.

FIS-6801 Industrial Scanner User’s Manual

4-9

Page 70

Camera Setup

Focus Distance Provides focal distance adjustment for the camera. When “Distance units” is set to “millimeters”, the Focal Distance parameter has a range of 25 to 4000. Any value outside this range will be rejected. When “Distance units” is set to “1/100 inch”, Focal Distance is limited to a range of 100 to 4000. If the user attempts to set the Focal distance to less than 100 (1 inch), the parameter will be set to 100. When a lens is changed on the FIS-6801, the user can improve the accuracy of the Focal Distance parameter by using the <@OPTIC> command. Important: <@OPTIC> is not supported by the FIS-6801 C-Mount Imager. Even after running <@OPTIC> the system distance accuracy is approximate. The command gives reasonable step sizes as apposed to completely unknown magnitudes but it is not expected that 2 units will exhibit the same exact focus for a given setting.

Distance Units Defines the measurement unit value of the Focal Distance parameter. Required Focal DistanceDistance Units = millimeter (0) Distance Units = 1/00 inch (1)

4-10

FIS-6801 Industrial Scanner User’s Manual