For the Wenglor FIS-6801
Page 51
Hardware Installation
FIS-6801 and ZAA12NN01 Connectors and Pinouts (continued) RS-422/485 RxD (–) Input Common
RS-232 TxD/ RS-232 RTS Trigger
Ground
RS-232 RxD/ RS-232 CTS
RS-422/485 RxD (+)
Power
RS-422/485 TxD (+)
Terminated Terminated
RX (–)
RX (+) Terminated
Input 1
Terminated
RS-422/485 TxD (–)
Function Trigger Power Terminated Input 1 Port 3 422/485 TxD (+) Port 3 422/485 RxD (+) Ground Input Common Port 2 TxD/Port 1 RTS Port 2 RxD/Port 1 CTS Port 3 422/485 TxD (–) Port 3 422/485 RxD (–)
TX (–) Terminated
B (Serial Models) M12 12-pin Socket Pin 1 2 3 4 5 6 7 8 9 10 11 12
TX (+)
Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue
FIS-6801 Industrial Scanner User’s Manual
B (Ethernet Models) M12 8-pin Socket Pin 1 2 3 4 5 6 7 8
Function Terminated Terminated Terminated TX (–) RX (+) TX (+) Terminated RX (–)
3-7
Page 52
FIS-6801 and ZAA12NN01 Connectors and Pinouts
Grounding the FIS-6801 Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.
FIS-6801
An earth ground is provided through the cable shields and chassis of the Scanner.
Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, Scanner, and their power supplies are connected to a common earth ground.
3-8
FIS-6801 Industrial Scanner User’s Manual
Page 53
Hardware Installation
Expected Power and Ground Connections for Proper Operation
Grounding Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the Scanner. • “Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.
FIS-6801 Industrial Scanner User’s Manual
3-9
Page 54
FIS-6801 and ZAA12NN01 Connectors and Pinouts
ZAA12NN01 Interface Device The ZAA12NN01 Interface Device’s receptacles are physically the same as those on the FIS-6801, but they do not have explicit pin assignments. The ZAA12NN01 allows users to bus power and communications as required by the application. Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin socket. All three connectors can be assigned to bus power and data as required by the application. The two switches at the center of the device allow the user to route signals as needed. 1, 3 1,3, T
PWR TRIG
1,2, 3 1,2, 3, T
ZAA12NN01 Interface Pin 1 2 3 4
Assignment + 10-28V Trig/NM/Input 1 Common Ground Trigger
ZAA12NN01 Trigger Connector 4-pin This simple diagram (shown on the base of the ZAA12NN01) illustrates how power, communications, I/O, and trigger signal can be routed through the ZAA12NN01 device depending on the needs of the application. The switches greatly increase signal routing flexibil-
ZAA12NN01 Communications - I/O - Power - Trigger
3-10
FIS-6801 Industrial Scanner User’s Manual
Page 55
Hardware Installation
Power and Trigger Switching
1, 3 1,3, T
PWR TRIG
1,2, 3 1,2, 3, T
Power can be bussed between Scanners and interface devices. At each location on a network where a new power supply is added, the Power switch on the ZAA12NN01 can be used to break power between Connector 2 and Connectors 1, 3, and T. The Trigger signal between Connector 2 and Connectors 1, 3, and T can be broken using the Trigger switch. This isolates trigger signals as required by the application.
FIS-6801 Industrial Scanner User’s Manual
3-11
Page 56
Port Routing
Port Routing The physical advantages created by flexible signal routing and switching are enhanced further by Port Routing, which can be configured in ESP. Port Routing eliminates the need for dedicated “Host” and “Aux” ports in a traditional sense. With Port Routing, any port can be defined as a Host or Aux port. Port Routing also allows users to define the data types that are accessible from specific ports. The primary benefit of Port Routing is that any type of data can be routed to any port, and can be sent through multiple ports simultaneously. Multiple types of data can also be appended to the symbol data that is output from the Scanner to the host. Command data, symbol data, extra symbol information, and diagnostic data are enabled by default in the FIS-6801. The table below lists different types of data, with examples for each data type. Data Type
Example
Command Data
Serial commands; Scanner responses to serial commands.
Symbol Data
Any string of data encoded in a symbol.
Extra Symbol Information
Decodes per trigger, decode direction, configuration database index number.
Diagnostic Data
Service message.
The screen capture below (from ESP) shows the FIS-6801’s four communications ports and the parameters for each.
RS-232 A, RS-232 B, and RS-422 are serial. RS-232 A is always enabled. RS-232 B and RS-422 can be enabled or disabled to match the physical requirements of the application. Ethernet can also be enabled or disabled as required. RS-232 A, RS-232 B, and RS-422 can be configured for Baud Rate, Parity, Stop Bits, Data Bits, Symbol Data Output, Extra Symbol Information (Decodes Before Output, Symbol Position Output, etc.), Diagnostics Output, and External Source Processing Mode (Command or Data). Ethernet can be configured for IP Address, Subnet Mask, Gateway, IP Address Mode, Symbol Data Output, Extra Symbol Information, Diagnostics Output, and External Source Processing Mode.
3-12
FIS-6801 Industrial Scanner User’s Manual
Page 57
Hardware Installation
Application Examples The following examples demonstrate how the components described in previous pages can be deployed in industrial applications.
Daisy Chain Daisy chain configurations are used in applications such as product packaging, where single items have multiple symbols. For example, a box with one symbol on the top and symbols on either side requires at least three Scanners to ensure that all symbols will be decoded. The highlighted areas below demonstrate how a daisy chain can be arranged. One Scanner is placed above the conveyor line and one Scanner is placed on each side of the line. The three Scanners essentially function as a single Scanner, and data is sent from the primary Scanner to the host or PLC. Important: Do not attempt to power more than four Scanners with a single power supply in a daisy chain configuration. Add a ZAA12NN01 and one power supply for every four additional Scanners in the daisy chain.
FIS-6801 Industrial Scanner User’s Manual
3-13
Page 58
Application Examples
Multidrop Multidrop networks are used in applications where it is necessary to decode symbols at multiple locations within an industrial process. Scanners are placed at stations located between manufacturing steps, and data from those Scanners is directed to a multidrop concentrator before being sent to a host. An example of this type of application is food packaging, in which part number data is collected and tracked throughout the packaging process. The highlighted areas below demonstrate how a multidrop network can be arranged.
3-14
FIS-6801 Industrial Scanner User’s Manual
Page 59
Hardware Installation
Ethernet TCP/IP Ethernet TCP/IP is the standard Ethernet interface used to connect multiple locations in a network, such as computers in an office network. It can also be used to network other communications devices, such as Scanners and PLCs on a factory floor. The highlighted areas below demonstrate how an Ethernet daisy chain can be arranged. Ethernet-enabled Scanners can also be set up in standalone configurations, or multiple Ethernet-enabled Scanners along a production or packaging line can be connected to Ethernet.
FIS-6801 Industrial Scanner User’s Manual
3-15
Page 60
Application Examples
3-16
FIS-6801 Industrial Scanner User’s Manual