Page 41
Using ESP
Send/Receive Options To access Receive, Save, and Default options, click the Send/Recv button. These options can also be reached by right-clicking in any of the configuration views.
Receiving From the Send/Recv menu, select Receive Reader Settings. Caution: Selecting this option will upload the Scanner’s settings. If the ESP file has a number of custom settings that must be maintained and downloaded into the Scanner, these settings will be lost. This function is useful for receiving (uploading) the Scanner’s settings and saving them as a file for future use. For example, if the Scanner has settings that must not change, Receive Reader Settings would load those settings to ESP and save them in an ESP file for later retrieval. Receiving the Scanner’s settings will also assure that any unwanted subsequent changes in ESP will not be saved.
Saving Send, No Save (<A>) Saves ESP settings to current memory.
Send and Save (<Z>) Activates all changes in current memory and saves to the Scanner for power-on.
Send and Save as Customer Defaults (<Zc>) Saves default settings for quick retrieval. This option will be visible only if Enable ‘Send and Save as Customer Defaults’ is checked in ESP Preferences.
FIS-6801 Industrial Scanner User’s Manual
2-17
Page 42
Send/Receive Options
Defaulting When Default Current Menu Settings or Default all ESP Settings are selected, only the ESP settings are defaulted.
Advanced Options Send Current View This is the same as Save to Reader > Send No Save except that only the commands in the current configuration tree are sent.
Send Current Command This is the same as Send Current View, except that it saves only the command that is currently selected.
Add/Remove Exception After a Receive Reader Settings command is performed1 and the Add Exception option is selected, a list of serial commands may appear. These are commands that may be in the Scanner’s firmware, but are not included in, or are different from, the current version of ESP. These commands can be edited by double-clicking them and changing them as needed. It is important to note that these commands will be saved to the Scanner whenever a Save to Reader command is sent, or when an <A> or a <Z> command is sent. Also, if there is a corresponding ESP menu item, the ESP Value column for that item will be blank following a Receive Reader Settings command.
1. From the Send/Recv button or by right-clicking in any blank section of a tree control view.
2-18
FIS-6801 Industrial Scanner User’s Manual
Page 43
Using ESP
FIS-6801 Industrial Scanner User’s Manual
2-19
Page 44
Send/Receive Options
2-20
FIS-6801 Industrial Scanner User’s Manual
Page 45
3 Hardware Integration Contents Connectors ................................................................................................................................... 3-2 Cordsets ....................................................................................................................................... 3-3 FIS-6801 and ZAA12NN01 Connectors and Pinouts ................................................................... 3-4 Power and Trigger Switching........................................................................................................ 3-9 Port Routing................................................................................................................................ 3-10 Application Examples ................................................................................................................. 3-11
This section introduces the details of FIS-6801 hardware, and explains how that hardware can be integrated in an application.
FIS-6801 Industrial Scanner User’s Manual
3-1
Page 46
Connectors
Connectors Industrial cabling and connectivity schemes must be able to withstand environmental extremes of heat, cold, and moisture, and be secure enough not to be disconnected or damaged inadvertently in the course of day-to-day operation. The current industry standard for connectivity is a sealed, circular connector such as the M12. The International Electrotechnical Commission (IEC) standard for M12 connectors describes them as fixed and free screw-locking connectors. This type of connector is widely available off-the-shelf from manufacturers such as Turck, Lumberg, Phoenix Contact, or Binder. The FIS-6801 uses sealed, circular connectors with Ultra-Lock™ technology. Ultra-Lock connectors are more resistant to harsh industrial conditions, and are easy to connect.
Ultra-Lock Connectors wenglor has adopted Ultra-Lock connectivity because of speed, ease-of-use, and ingress protection considerations. The main advantage of the Ultra-Lock system is that only two steps are required at every connection point: 1. Align the connector and receptacle keys; 2. Push the connector into place. (Do not twist the connector, as this can bend the pins.) Ultra-Lock connectors are “operator-independent”. This means that they are not subject to under-tightening or over-tightening, both of which are common problems with screw-down connectors, and both of which undermine the moisture-resistant seal.
Ultra-Lock Connector
Traditional Threaded Connectors
Another advantage of the FIS-6801’s Ultra-Lock connectivity scheme is that the Ultra-Lock receptacles on the Scanners and the ZAA12NN01 Interface Device also accept screw-down connectors, giving users the flexibility to use either Ultra-Lock or screw-down connectors.
“Ultra-Lock” is a trademark of Woodhead (Molex).
3-2
FIS-6801 Industrial Scanner User’s Manual
Page 47
Hardware Installation
FIS-6801 Industrial Scanner User’s Manual
3-3
Page 48
Cordsets
Cordsets The terms “cordset” and “cable” are both applicable to industrial connectivity, but they are not synonymous. Cordsets enable communications and power between Scanners and interface devices. Cordsets have an M12 Ultra-Lock connector at one or both ends. Examples of cordsets are shown below.
M12 Ultra-Lock to M12 Ultra-Lock Cordset
M12 Ultra-Lock to RJ45 (Ethernet) Cordset
M12 Ultra-Lock to Photo Sensor Cordset
Cables do not have M12 Ultra-Lock connectors at either end. An example of a cable is shown below.
Cable with flying leads
3-4
FIS-6801 Industrial Scanner User’s Manual
Page 49
Hardware Installation
FIS-6801 and ZAA12NN01 Connectors and Pinouts When deploying a network of Scanners and interface devices in an industrial setting, it is important to use components whose pin assignments are arranged in a way that avoids communication errors and equipment damage. This can be achieved with components that are designed in a logical, consistent, and easy-to-implement way. The FIS-6801 has a very simple pin assignment methodology. The clearly identified connectors at the back of the unit can be used to receive and bus power, and also to send and receive data and commands. FIS-6801 Connectors
A is a serial M12 12-pin plug. It is the same for all models of the FIS-6801. B is a serial M12 12-pin socket for serial models and an Ethernet M12 8-pin socket for Ethernet models. Output 2 New Master
Default Power
Output 1
RS-232 (Host) TxD
Output 3
Trigger Ground RS-232 (Host) RxD
Input Common Output Common
A (All Models) M12 12-pin Plug Pin 1 2 3 4 5 6 7 8 9 10 11 12
Function Trigger Power Default New Master Output 1 Output 3 Ground Input Common RS-232 (Host) RxD RS-232 (Host) TxD Output 2 Output Common
Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue
FIS-6801 Industrial Scanner User’s Manual
3-5
Page 50
FIS-6801 and ZAA12NN01 Connectors and Pinouts Continued next page
3-6
FIS-6801 Industrial Scanner User’s Manual