Page 31
Using ESP
Preferences > Terminal Tab
Show Non-Printable Characters When Show Non-Printable Characters is enabled, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting.
Change Keyboard Macros Clicking the Change Keyboard Macros button brings up the Function Keys dialog. In this dialog, select the desired function key and then enter the macro keystrokes in the associated key map. For example, to make Ctrl-F2 the keystroke to send a trigger character, select F2, then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F2 keystroke is pressed, the trigger character will start the read cycle. Note: The F1 key is reserved for opening ESP Help and the F3 key is reserved for the Find Next function.
Change Font Allows the user to modify the font used for decode data received from the Scanner on the Terminal.
Change Echo Font Allows the user to modify the font used for command characters typed into the Terminal.
Enable Echo Allows the user to enter command characters in Terminal.
Display Incoming Data Even When Not in Focus When Display Incoming Data Even When Not in Focus is enabled, data from the Scanner will continue to appear in the Terminal even when ESP is not the top window.
FIS-6801 Industrial Scanner User’s Manual
2-7
Page 32
Menu Toolbar
Preferences > Bar Code Options Tab
Sizing Information Sets the bar height (in inches) and bar width (in mils, or thousandths of an inch) of user-created symbols. Example: A bar width of 18 mils is 0.018 inches.
2-8
FIS-6801 Industrial Scanner User’s Manual
Page 33
Using ESP
Preferences > Advanced Tab
The Auto Sync options at the top of the Advanced tab allow the user to determine whether Auto Sync will be enabled automatically in sections of ESP where it is used, or if it will ask before it enables Auto Sync functions.
Always Ask Before Auto Sync Occurs If this option box is checked, specific Auto Sync functions can be enabled. Receive Settings from the Reader will automatically send the Scanner’s settings to ESP when Auto Sync is enabled. Send ESP Settings to the Reader will automatically send all Scanner configuration settings chosen in ESP to the Scanner. Do Not Send or Receive Settings creates a condition in which Auto Sync will not automatically send Scanner settings to ESP, or send ESP settings to the Scanner.
Show Target Pattern During Locate Allows you to determine whether the blue LED target pattern will be on or off during the Locate routine.
Show Target Pattern During Calibrate Allows you to determine whether the blue LED target pattern will be on or off during the Calibrate routine.
Use Higher Quality Images Sets ESP to output images at a higher resolution than standard JPEG format.
Open Image after Save When Open Image after Save is enabled, ESP automatically opens saved image captures. Images can be saved from the Evaluation tab in the Camera view, or by right clicking an image in any other image capture view and then saving.
Send XON with Autoconnect Sends an XON (Begin Transmission) command to the Scanner before starting the Autoconnect routine. FIS-6801 Industrial Scanner User’s Manual
2-9
Page 34
Menu Toolbar
2-10
FIS-6801 Industrial Scanner User’s Manual
Page 35
Using ESP
Preferences > Advanced Tab (cont.) Ask to Save ESP File when Quitting When enabled, prompts the user to save a .esp file when ending a session.
The .esp file will be saved in the location specified by the user.
Connect to Readers via TCP/IP When enabled, shows the TCP/IP Connection Wizard by default.
Use Default Storage Location When enabled, automatically stores data in ESP’s Application Data folder. FIS-6801 Industrial Scanner User’s Manual
2-11
Page 36
Menu Toolbar
Document Memo The information entered in the Document Memo field will appear in a context-sensitive text box whenever the cursor hovers over the Document Memo item on the Options menu.
Model Memo Similar to Document Memo, the information entered in the Model Memo field will appear in a context-sensitive text box whenever the cursor hovers over the Model Memo item on the Options menu. Memos created in Model Memo are specific to the model enabled when the message was created.
Note: Memos must be saved in a .esp file to make them available in the next session. If the current session is not saved, any memos that have been entered during the session will be discarded, and will be unavailable in the next session.
2-12
FIS-6801 Industrial Scanner User’s Manual
Page 37
Using ESP
Connect The Connect dropdown menu allows the user to access the Connection Wizard, as well as the Autoconnect and Configure Multidrop dialogs. Connect and Disconnect can also be performed directly from the dropdown menu without opening a dialog.
Connection Wizard To connect using the Connection Wizard: • Click Connect on ESP’s menu toolbar, and then select Connection Wizard. • Select RS-232 or Ethernet to activate the appropriate display. • Configure RS-232 or Ethernet settings as required by the application, and click Connect.
Click the Search button to locate Scanners on the network.
RS-232 Connection Wizard
Ethernet Connection Wizard
• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible.
FIS-6801 Industrial Scanner User’s Manual
2-13
Page 38
Menu Toolbar
Autoconnect • If the RS-232 connection attempt fails, use Autoconnect to establish a connection between the Scanner and the host.
• If the communication port is not the default COM1, use the dropdown menu to change the port.
• Once you have chosen the correct port, click Start to connect.
• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible.
2-14
FIS-6801 Industrial Scanner User’s Manual
Page 39
Using ESP
View The View menu allows the user to move quickly between the Parameters, Setup, Terminal, and Utilities interfaces without using the icon buttons on the App Mode toolbar. It also allows the user to access the Bar Code Dialog, shown below.
Bar Code Dialog Symbols can be created in the Bar Code Dialog by typing the text to be encoded. This is a useful tool for creating configuration symbols, allowing the user to configure the Scanner by reading the user-created symbols.
Drag specific configuration values from the control tree directly into this field to encode new symbols. Choose a spatial orientation for the new symbol. Create a caption for the symbol that matches or describes the encoded data.
The symbol will be displayed in the field at the bottom of the Bar Code Dialog.
FIS-6801 Industrial Scanner User’s Manual
2-15
Page 40
Navigating in ESP
Navigating in ESP To change Scanner settings, or to access the Setup, Terminal, or Utilities views, click the App Mode button.
To return to EZ Mode, click the EZ Mode button.
To make changes to configuration settings in the tree controls:
The X indicates that the setting is default.
1. Left-click on the + to expand menu items. 2. Double-click the desired parameter and single-click in the selection box to view options. 3. Place the cursor in the selection box, scroll down 4. Left-click again on the open screen to complete the to the desired setting, and selection. single-click the setting. 5. Right-click on the open screen and select Save to Reader to implement the command in the Scanner. The command can be sent without saving, or sent and saved simultaneously.
2-16
FIS-6801 Industrial Scanner User’s Manual