The text of a manual · part 40 of 46
FIS-6801 Industrial Scanner User's Manual, pages 391 to 400
Pages 391 to 400 of 454
The original document is the PDF (7.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6801
Page 391
Appendices
Trend Analysis Output 2 Serial Cmd:
<K781,trend analysis mode,trigger evaluation period,number to output on>
Trend Analysis Output 3 Serial Cmd:
<K782,trend analysis mode,trigger evaluation period,number to output on>
Diagnostics Output 1 Service Unit Serial Cmd: Default: Options:
<K790,service unit> 0 = Disabled 0 = Disabled
1 = Enabled
Diagnostics Output 2 Serial Cmd:
<K791,service unit>
Diagnostics Output 3 Serial Cmd:
<K792,service unit>
FIS-6801 Industrial Scanner User’s Manual
A-63
Page 392
Serial Commands
Output 1 Parameters Output On Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> Mismatch or No Read 0 = Mismatch or No Read 1 = Match or Good Read 2 = Mismatch 3 = No Read 4 = Trend Analysis 5 = Validation 6 = Diagnostic Warning 7 = In Read Cycle 8 = Read Cycle Data Valid
Output State Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 0 = Normally Open 0 = Normally Open 1 = Normally Closed
Pulse Width Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 500 1 to 65535 (in 1 ms increments)
Output Mode Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 0 = Pulse 0 = Pulse 1 = Latch Mode 1 (Unlatch Input 1 Pin) 2 = Latch Mode 2 (Unlatch Opposite Condition) 3 = Latch Mode 3 (Unlatch Re-Enter Read Cycle)
Output 2 Parameters Serial Cmd:
<K811,output on,output state,pulse width,output mode>
Output 3 Parameters Serial Cmd:
A-64
<K812,output on,output state,pulse width,output mode>
FIS-6801 Industrial Scanner User’s Manual
Page 393
Appendices
Matchcode Matchcode Master Symbol Database Size New Master Pin Master Symbol Match Replace Mismatch Replace
<K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K231,index,master symbol data> <K735,status,replacement string> <K736,status,replacement string>
Matchcode Type Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Wild Card 3 = Sequential
Sequential Matching Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Increment 0 = Increment 1 = Decrement
Match Start Position Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 0 to 3000
Match Length Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 1 to 3000
FIS-6801 Industrial Scanner User’s Manual
A-65
Page 394
Serial Commands Wild Card Character Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> * (asterisk) Any 7-bit ASCII character
Sequence on No Read Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 = Enabled 0 = Disabled 1 = Enabled
Sequence on Mismatch Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Disabled 0 = Disabled 1 = Enabled
Master Symbol Database Size Serial Cmd: Default: Options:
<K224,number of master symbols> 1 1 to 10
New Master Pin Serial Cmd: Default: Options:
<K225,status> 0 = Disabled 0 = Disabled
1 = Enabled
Master Symbol Index Serial Cmd: Options:
<K231,index,master symbol data> 1 to 32768
Master Symbol Data Serial Cmd: Options:
<K231,index,master symbol data> Any valid ASCII string
Match Replace Serial Cmd: Default: Options: A-66
<K735,status,replacement string> 0 = Disabled 0 = Disabled 1 = Enabled FIS-6801 Industrial Scanner User’s Manual
Page 395
Appendices Replacement String Serial Cmd: Default: Options:
<K735,status,replacement string> MATCH Any valid ASCII string up to 128 characters
Mismatch Replace Serial Cmd: Default: Options:
<K736,status,replacement string> 0 = Disabled 0 = Disabled 1 = Enabled
Replacement String Serial Cmd: Default: Options:
<K736,status,replacement string> MISMATCH Any valid ASCII string up to 128 characters
FIS-6801 Industrial Scanner User’s Manual
A-67
Page 396
Serial Commands
Diagnostics Hours Since Reset (Read-only) Service Message User-Defined Name
<K407> (returns: hours,minutes) <K409,status,service message, threshold,resolution> <K412,user-defined name>
Hours Since Reset (Read-only) Hours Serial Cmd:
<K407,hours,minutes> 16-bit counter (0 to 65535)
Minutes Serial Cmd:
<K407,hours,minutes> 16-bit counter (0 to 60)
Service Message Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 0 = Disabled 0 = Disabled 1 = Enabled
Service Message Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> SERVICE Any valid ASCII string up to 128 characters
Threshold Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 300 (5 minutes) 1 to 65535
Resolution Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 0 = Seconds 0 = Seconds 1 = Minutes
User-Defined Name Serial Cmd: Default: Options:
A-68
<K412,user-defined name> FIS-6801 Any valid ASCII string up to 50 characters
FIS-6801 Industrial Scanner User’s Manual
Page 397
Appendices
Output Format Format Extract Format Insert Format Assign Output Format Status Output Filter Configuration Output Filter Enable
<K740,output index,start location,length> <K741,output index,length,hex string> <K742,symbol number,status> <K743,output format status> <K744,filter number,symbology,length,wildcard,placeholder, data,unused,database index> <K745,number of filters>
Format Extract Output Index Serial Cmd:
<K740,output index,start location,length>
Options:
1 to 100
Start Location Serial Cmd:
<K740,output index,start location,length>
Default:
0
Options:
1 to n (maximum number of characters in the symbol data).
Length Serial Cmd:
<K740,output index,start location,length>
Default:
0 (Disabled; end of format cell array)
Options:
1 to n (maximum number of characters in the symbol data).
Format Insert Output Index Output Index refers to the database entry to be modified with this command. A formatted output is built by extracting data from a symbol’s original data output and/or inserting user-defined characters. It may be helpful to think of individual indexes as positions in the final formatted output. Starting with index # 1, enter either an extract or insert command to begin building the required output string. Then, with the next index number, enter either an extract or insert command to continue building the output string. Continue this process until the string is complete. Serial Cmd: <K741,output index,length,hex string> Options:
1 to 100
FIS-6801 Industrial Scanner User’s Manual
A-69
Page 398
Serial Commands Length Specifies the length of the user-defined character string that will be inserted. This function is limited to 4 characters per output index, so multiple indexes must be entered in order to insert longer character sequences. For example, to insert a 10-character sequence in user-defined output, three commands with consecutive index numbers would be required, where the first two character sequence lengths were 4 and the third was 2. Serial Cmd: <K741,output index,length,hex string> Default:
0 (Disabled; end of format cell array)
Options:
1 to 4
Hex String Specifies a character string that represents ASCII characters to be inserted in the database entry. Two hex characters are required for every ASCII character to be inserted in the user-defined output string. These two characters comprise the hex (base 16) value of the ASCII character. For example, to enter the three-character sequence “Hi!”, 3 would indicate the length of the string, and a hex sequence of 486921 would be the ASCII sequence to be inserted. (48 = H; 69 = i; 21 = !) Important: Each pair of hex characters represents one ASCII character. Hex character pairs range from 00 to FF. Since there is a limit of 4 ASCII characters per insertion per database entry, there is a limit of 8 hex characters per insertion per database entry. Serial Cmd: <K741,output index,length,hex string> Default:
NULL (0x00)
Options:
00 to FF (As many as 4 bytes, or hex pairs.)
A-70
FIS-6801 Industrial Scanner User’s Manual
Page 399
Appendices
Format Assign Symbol Number Serial Cmd: <K742,symbol number,status> Options:
1 to 10 1 = Formatted output status for symbol # 1. 2 = Formatted output status for symbol # 2. ... ... 10 = Formatted output status for symbol # 10.
Status Serial Cmd: <K742,symbol number,status> Default:
0 = Disabled
Options:
0 = Disabled 1 = Enabled (Assign parameters to specified symbol.)
Output Format Status Serial Cmd: <K743,output format status> Default:
0 = Disabled
Options:
0 = Disabled 1 = Enabled
Output Filter Configuration Filter Number Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Options:
1 to 10
FIS-6801 Industrial Scanner User’s Manual
A-71
Page 400
Serial Commands Symbology Type Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0
Options:
0 = Any type 1 = Interleaved 2 of 5 2 = Code 39 3 = Code 128 4 = Codabar 5 = UPC 6 = PDF417 7 = EAN 128 8 = Code 93 9 = Pharmacode 10 = GS1 DataBar 11 = MicroPDF417 12 = Composite 13 = BC412 14 = Data Matrix 15 = QR Code
Length Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0
Options:
0 to 128
Wildcard Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
* = (0x2A)
Options:
Any ASCII input in the form of a pair of hex characters
Placeholder Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
? = (0x3F)
Options:
Any ASCII input in the form of a pair of hex characters
A-72