Page 381
Appendices Options:
1 to 128
PDF417 Serial Cmd: Default: Options:
<K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:
<K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (PDF417) Serial Cmd: Default: Options:
<K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 10 1 to 2710
Decode at End of Read Cycle (PDF417) Serial Cmd: Default: Options:
<K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Pharmacode Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 10 1 to 16
FIS-6801 Industrial Scanner User’s Manual
A-53
Page 382
Serial Commands Minimum Bars (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 4 1 to 16
Bar Width Status (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Direction (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Forward 0 = Forward 1 = Reverse
Fixed Threshold Value (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 400 1 to 65535
GS1 DataBar (RSS) DataBar Omnidirectional (RSS-14) Serial Cmd: Default: Options:
<K482,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Limited (RSS Limited) Serial Cmd: Default: Options:
<K483,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Expanded (RSS Expanded) Serial Cmd: Default: Options: A-54
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled FIS-6801 Industrial Scanner User’s Manual
Page 383
Appendices Fixed Symbol Length Status (DataBar Expanded) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (DataBar Expanded) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74
MicroPDF417 Serial Cmd: Default: Options:
<K485,status,unused,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (MicroPDF417) Serial Cmd: Options:
<K485,status,fixed symbol length status,fixed symbol length> 1 to 366
FIS-6801 Industrial Scanner User’s Manual
A-55
Page 384
Serial Commands
Camera Setup Window of Interest Focus Distance Illumination (Standard FIS-6801 Only) Camera Settings Sub-Sampling Morphological Pre-Processing Morphological Operations External Illumination Mode
<K516,row pointer,column pointer,row depth,column width> <K525,focal distance,distance units,lens type> <K539,mode,brightness> <K541,shutter speed,gain> <K542,sub-sampling> <K550,status> <K551,unused,operation,size> <K553,mode>
I/O Parameters Calibration Options (Standard FIS6801) Calibration Options (FIS-6801 C-Mount) Serial Verification Beeper Quality Output Symbol Data Output Read Duration Output Global Symbol Quality Output ISO/IEC 16022 Parameters Data Matrix Grading No Read Message Input 1 Frame Information ISO/IEC 16022 Grade LED Display Green Flash LED Status Indicators EZ Trax Output Database Identifier Output EZ Button EZ Button Modes Trend Analysis Output 1 Trend Analysis Output 2 Trend Analysis Output 3
A-56
<K529,gain,shutter speed,focus position,symbol type,window of interest framing,window of interest margin> <K529,gain,shutter speed,unused,symbol type,unused,unused> <K701,serial command echo status, serial command beep status, control/hex output> <K702,status> <K704,quality output separator, decodes per trigger status> <K705,symbol data output status, when to output symbol data> <K706,status,separator> <K708,quality output separator,output mode> <K709,symbol contrast,print growth,axial non-uniformity,unused ECC> <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> <K714,status,message> <K730,input mode,active state> <K734,output frame number,output coordinates> <K737,unused,LED AIM LED display> <K750,LED status,targeting status,green flash duration> <K751,comm,bar graph,I/O 1,I/O 2> <K757,status,port,image mode,image format,image quality, object info enable,grade enable> <K759,status,separator character> <K770,global status,default on power-on,load configuration database, save for power-on> <K771,first beep,second beep,third beep,fourth beep> <K780,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output on,decodes per trigger> FIS-6801 Industrial Scanner User’s Manual
Page 385
Appendices Diagnostics Output 1 Diagnostics Output 2 Diagnostics Output 3 Symbol Quality Output 1
Symbol Quality Output 2
Symbol Quality Output 3 Output 1 Parameters Output 2 Parameters Output 3 Parameters
<K790,unused,service unit> <K791,unused,service unit> <K792,unused,service unit> <K800,Output on Symbol Contrast,Symbol Contrast Threshold, Output on Print Growth,Print Growth Threshold,Output on Axial Non-Uniformity,Axial Non-Uniformity Threshold,Output on Unused ECC,Unused ECC Threshold> <K801,Output on Symbol Contrast,Symbol Contrast Threshold, Output on Print Growth,Print Growth Threshold,Output on Axial Non-Uniformity,Axial Non-Uniformity Threshold,Output on Unused ECC,Unused ECC Threshold> <K802,Output on Symbol Contrast,Symbol Contrast Threshold, Output on Print Growth,Print Growth Threshold,Output on Axial Non-Uniformity,Axial Non-Uniformity Threshold,Output on Unused ECC,Unused ECC Threshold> <K810,output on,output state,pulse width,output mode> <K811,output on,output state,pulse width,output mode> <K812,output on,output state,pulse width,output mode>
Serial Verification Serial Command Echo Status Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled
Serial Command Beep Status Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled
Control/Hex Output Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status,control/hex output> 0 = Control 0 = Control 1 = Hex
Beeper Serial Cmd: Default: Options:
<K702,beeper status> 1 = Good Read 0 = Disabled 1 = Good Read
2 = No Read
Quality Output
FIS-6801 Industrial Scanner User’s Manual
A-57
Page 386
Serial Commands Separator Serial Cmd: Default: Options:
<K704,separator,decodes per trigger status> , (comma) Any 7-bit ASCII character
Decodes per Trigger Status Serial Cmd: Default: Options:
<K704,separator,decodes per trigger status> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Data Output Symbol Data Output Status Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 3 = Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read
When to Output Symbol Data Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 0 = As Soon As Possible 0 = ASAP 1 = End of Read Cycle
Symbology ID Output Status Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 0 = Disabled 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID
Read Duration Output Read Duration Output Mode Serial Cmd: Default: Options:
<K706,status,separator> 0 = Disabled 0 = Disabled 1 = Enabled
Read Duration Output Separator Serial Cmd: Default: Options:
<K706,status,separator> Space (0x20) Any 7-bit ASCII character
No Read Message A-58
FIS-6801 Industrial Scanner User’s Manual
Page 387
Appendices No Read Message Status Serial Cmd: Default: Options:
<K714,No Read message status,No Read message> 1 = Enabled 0 = Disabled 1 = Enabled
No Read Message Serial Cmd: Default: Options:
<K714,no read message status,No Read message> NOREAD Any valid ASCII string up to 128 characters
Input 1 Serial Cmd: Default: Options:
<K730,status,active state> 0 = Disabled 0 = Disabled 1 = Reset Counts 2 = Unlatch Output
Active State Serial Cmd: Default: Options:
<K730,status,active state> 0 = Active Open 0 = Active Open 1 = Active Closed
Green Flash LED (Standard FIS-6801 Only) Green Flash Mode Serial Cmd: Default: Options:
<K750,green flash mode,unused,green flash duration> 1 = Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe
Green Flash Duration Serial Cmd: Default: Options:
<K750,green flash mode,unused,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)
Status Indicators Serial Cmd: Default:
<K751,status,bar graph,I/O 1,I/O 2> 1 = PHY Activity
FIS-6801 Industrial Scanner User’s Manual
A-59
Page 388
Serial Commands Options:
0 = Disabled 1 = PHY Activity 2 = Protocol Activity
Bar Graph Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 1 = Read Rate / Good Read 0 = Disabled 1 = Read Rate / Good Read 2 = Symbol Grade
I/O 1 Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 1 = Output Active 0 = Disabled 1 = Output Active 2 = Input Active
I/O 2 Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 2 = Input Active 0 = Disabled 1 = Output Active 2 = Input Active
Database Identifier Output Serial Cmd: Default: Options:
<K759,status,separator> 0 = Disabed 0 = Disabled 1 = Enabled
Separator Serial Cmd: Default: Options:
<K759,status,separator> Space (0x20) Any 7-bit ASCII character
EZ Button Global Status Serial Cmd: Default:
A-60
<K770,global status,default on power-on> 1 = Enabled
FIS-6801 Industrial Scanner User’s Manual
Page 389
Appendices Options:
0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch
Default on Power-On Serial Cmd: Default: Options:
<K770,global status,default on power-on> 1 = Enabled 0 = Disabled 1 = Enabled
EZ Button Modes (Standard FIS-6801) Serial Cmd: Options:
<K771,first beep,second beep,third beep,fourth beep> 0 = Disabled 1 = Enabled
Single Beep 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
FIS-6801 Industrial Scanner User’s Manual
Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
Four Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
A-61
Page 390
Serial Commands
EZ Button Modes (FIS-6801 C-Mount) Serial Cmd: Options:
<K771,first beep,second beep,third beep,fourth beep> 0 = Disabled 1 = Enabled
Single Beep 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Four Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Trend Analysis Output 1 Trend Analysis Mode Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 1 = No Read 0 = Mismatch 1 = No Read 2 = Decodes per Trigger
Trigger Evaluation Period Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255
Number to Output On Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255
Decodes per Trigger Threshold Serial Cmd: Default: Options: A-62
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 65535