Page 371
Appendices Options:
Any 7-bit ASCII character
Start Trigger Start Character (Non-Delimited) Serial Cmd: Default: Options:
<K229,start character> NULL (0x00) Two hex digits representing any ASCII character except <, >, XON, and XOFF.
Stop Trigger Stop Character (Non-Delimited) Serial Cmd: Default: Options:
<K230,stop character> NULL (0x00) Two hex digits representing any ASCII character except <, >, XON, and XOFF.
Processing Timeout Serial Cmd: Default: Options:
<K245,processing timeout> 200 (0.2 seconds) 1 to 65535
FIS-6801 Industrial Scanner User’s Manual
A-43
Page 372
Serial Commands
Configuration Database Number of Active Indexes <K252,number of active indexes,sort database> <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column Configuration Database pointer,row depth,column width,symbol type,morphology operation,morphology (Standard FIS-6801) size> Configuration Database <K255,index,shutter speed,gain,unused,sub-sampling,row pointer,column (FIS-6801 C-Mount) pointer,unused,column width,unused,unused,unused> Load Current Setting from <K255–,index> Configuration Database Request Database Index <K255?,index> Setting Request All Database <K255?> Settings <K256,switch mode,frame count/time,image process looping, image dimensions> Database Mode
Number of Active Indexes Number of Active Indexes Serial Cmd: Default: Options:
<K252,number of active indexes,number of database cycles> 0 (Disabled) 0 to 10
Number of Database Cycles Serial Cmd: Default: Options:
A-44
<K252,number of active indexes,number of database cycles> 0 (Disabled) 0 to 255
FIS-6801 Industrial Scanner User’s Manual
Page 373
Appendices
Symbologies Composite Aztec Micro QR Code Postal Symbologies Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode Data Matrix QR Code BC412 DataBar Omnidirectional DataBar Limited DataBar Expanded MicroPDF417
<K453,symbology status,separator status,separator> <K458,status> <K459,status> <K460,postal type,POSTNET status, PLANET status,USPS4CB status,POSTNET allow B and B’ fields,Australia Post allow 0 FCC> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar,range mode status> <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplementals type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN status,output format,application record separator status, application record separator character,application record brackets, application record padding> <K475,status,fixed symbol length status,fixed symbol length> <K476,status,unused,fixed symbol length status,fixed symbol length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value,background> <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status> <K480,status> <K481,status,check character output,fixed symbol length status, fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,unused,fixed length status,fixed symbol length>
Composite Symbology Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required
Separator Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled
FIS-6801 Industrial Scanner User’s Manual
A-45
Page 374
Serial Commands Separator (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> , (comma) Any 7-bit ASCII character
Code 39 Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 1 = Enabled 0 = Disabled 1 = Enabled
Check Character Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Check Character Output Status (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Large Intercharacter Gap (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 39) Serial Cmd:
A-46
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> FIS-6801 Industrial Scanner User’s Manual
Page 375
Appendices Default: Options:
10 1 to 128
Full ASCII Set (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Codabar Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Start/Stop Match (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled
Start/Stop Output (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled
Large Intercharacter Gap (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
FIS-6801 Industrial Scanner User’s Manual
A-47
Page 376
Serial Commands Symbol Length (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 10 1 to 128
Check Character Type (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Both Mod 16 and NW7 (Mod 11)
Check Character Output (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Interleaved 2 of 5 Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled
Check Character Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Check Character Output Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
A-48
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
FIS-6801 Industrial Scanner User’s Manual
Page 377
Appendices Symbol Length #1 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 128
Symbol Length #2 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 128
Guard Bar Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Range Mode Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled
UPC/EAN Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
EAN Status Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 1 = Enabled 0 = Disabled 1 = Enabled
Supplementals Status (UPC/EAN) Serial Cmd: Default:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled
FIS-6801 Industrial Scanner User’s Manual
A-49
Page 378
Serial Commands Options:
0 = Disabled
1 = Enabled
2 = Required
Separator Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
Separator Character (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any 7-bit ASCII character
Supplemental Type (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Both 0 = Both 1 = 2 characters only 2 = 5 characters only
Format UPC-E as UPC-A (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
Code 128/EAN 128 Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
Fixed Symbol Length Status (Code 128/EAN 128) Serial Cmd:
Default: A-50
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled FIS-6801 Industrial Scanner User’s Manual
Page 379
Appendices Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding, separation factor> 10 1 to 128
EAN 128 Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Required
Output Format (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Standard 0 = Standard 1 = Application
Application Record Separator Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Separator Character (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> , (comma) Any 7-bit ASCII character
FIS-6801 Industrial Scanner User’s Manual
A-51
Page 380
Serial Commands Application Record Brackets (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Padding (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Separation Factor Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Normal 0 = Normal 1 = High 2 = Highest
Code 93 Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
Fixed Symbol Length Status (Code 93) Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length (Code 93) Serial Cmd: Default: A-52
<K475,status,fixed symbol length status,symbol length> 10 FIS-6801 Industrial Scanner User’s Manual