Page 361

Appendices Extra Symbol Information, RS-422 Serial Cmd: Default: Options:

<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output, RS-422 Serial Cmd: Default: Options:

<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, RS-422 Serial Cmd: Default: Options:

<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

FIS-6801 Industrial Scanner User’s Manual

A-33

Page 362

Serial Commands

Ethernet TCP Port 1 Data Type Symbol Data Output, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extra Symbol Information, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

Ethernet TCP Port 2 Data Type Symbol Data Output, Ethernet TCP Port 2 Serial Cmd: Default: Options:

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extra Symbol Information, Ethernet TCP Port 2 Serial Cmd: Default: Options:

A-34

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

FIS-6801 Industrial Scanner User’s Manual

Page 363

Appendices Diagnostic Output, Ethernet TCP Port 2 Serial Cmd: Default: Options:

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, Ethernet TCP Port 2 Serial Cmd: Default: Options:

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

Preamble Preamble Status Serial Cmd: Default: Options:

<K141,status,preamble character(s)> 0 = Disabled 0 = Disabled 1 = Enabled

Preamble Characters Serial Cmd: Default: Options:

<K141,status,preamble character(s)> CR (0x0D) 1 – 4 ASCII characters

Postamble Postamble Status Serial Cmd: Default: Options:

<K142,status,postamble character(s)> 1 = Enabled 0 = Disabled 1 = Enabled

Postamble Characters Serial Cmd: Default: Options:

<K142,status,postamble character(s)> CR LF (0x0D 0x0A) 1 – 4 ASCII characters

Response Timeout Serial Cmd: Default: Options:

<K143,response timeout> 5 (x10 ms = 50) 0 to 255 (x10 ms)

LRC Status Serial Cmd:

<K145,status>

FIS-6801 Industrial Scanner User’s Manual

A-35

Page 364

Serial Commands Default: Options:

0 = Disabled 0 = Disabled

1 = Enabled

ACK/NAK Options Serial Cmd:

<K147,RES,REQ,STX,ETX,ACK,NAK>

RES-NAK Defaults RES: (Reset) REQ: (Request) STX: (Start of Text) ETX: (End of Text) ACK: (Acknowledge) NAK: (Negative Acknowledge)

00 (disabled) 00 (disabled) 00 (disabled) 00 (disabled) 06 15

Polling Mode Options Serial Cmd:

<K148,RES,REQ,STX,ETX,ACK,NAK>

RES-NAK Defaults RES: (Reset) REQ: (Request) STX: (Start of Text) ETX: (End of Text) ACK: (Acknowledge) NAK: (Negative Acknowledge)

04 05 02 03 06 15

Autoconfiguration Daisy Chain Serial Cmd:

A-36

<K150DAISY>

FIS-6801 Industrial Scanner User’s Manual

Page 365

Appendices

ASCII Character Entry Modifier Commands that require ASCII text fields, such as Preamble and Postamble commands, can be sent to the Scanner as hex pairs (see Appendix G, ASCII Table, for conversions). Serial Cmd Format: <Knnnh,00-FF> To enter ASCII fields as hex values (00 to FF), add a lower-case h directly after the command’s K number, and then enter the hex value that corresponds with the desired ASCII character. Example: Serial Cmd:

<K142,status,postamble character(s)>

The ASCII characters <, >, and , can only be entered as hex pairs. So, to make > the postamble in the symbol decode output, enter the Postamble command as follows: <K142h,,3E> Note that the “status” field contains only a , . This is because the only field that is being changed is the “postamble character(s)” field. (See Serial Configuration Command Conventions for a more detailed explanation of this command shortcut.)

Protocol Selection Protocol Serial Cmd: Options:

<K160,protocol,address,protocol port> 0 = Point-to-Point 1 = Point-to-Point with RTS/CTS 2 = Point-to-Point with XON/XOFF 3 = Point-to-Point with RTS/CTS and XON/XOFF 4 = ACK/NAK 5 = Polling Mode

FIS-6801 Industrial Scanner User’s Manual

A-37

Page 366

Serial Commands Address Serial Cmd: Default: Options:

<K160,protocol,address,protocol port> 1 1 – 50 1 = Poll address 0x1C, select address 0x1D 2 = Poll address 0x1E, select address 0x1F ... 50 = Poll address 0x7E, select address 0x7F

Protocol Port Serial Cmd: Default: Options:

<K160,protocol,address,protocol port> 0 0–1 0 = Main RS-232 on FIS-6801 Connector A 1 = RS-422/485 on FIS-6801 Connector B

External Data Routing Mode Serial Cmd: Default: Options:

<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Transparent 2 = Half Duplex 3 = Full Duplex 4 = Customized

Destination Port Serial Cmd: Default: Options:

A-38

<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = RS-232 on FIS-6801 Connector A 0 = RS-232 on FIS-6801 Connector A 1 = RS-232 on FIS-6801 Connector B 2 = RS-422 on FIS-6801 Connector B 4 = Ethernet TCP Port 1 5 = Ethernet TCP Port 2 6 = EtherNet/IP

FIS-6801 Industrial Scanner User’s Manual

Page 367

Appendices Ambles to Source Serial Cmd: Default: Options:

<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Enabled

Echo to Source Serial Cmd: Default: Options:

<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Enabled

Output at End of Read Cycle Serial Cmd: Default: Options:

<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Enabled

Output at ETX Serial Cmd: Default: Options:

<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> CR (0x0D) Any 7-bit ASCII character

Output at Timeout Serial Cmd: Default: Options:

<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 200 (x10 ms = 2 seconds) 0 – 65535

Array Communication Modes Mode Serial Cmd: Default: Options:

<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 0 = Disabled 0 = Disabled 1 = Daisy Chain

Source Serial Cmd: Default: Options:

<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 1 = RS-232 on FIS-6801 Connector B 0 = RS-232 on FIS-6801 Connector A 1 = RS-232 on FIS-6801 Connector B 2 = RS-422 on FIS-6801 Connector B

FIS-6801 Industrial Scanner User’s Manual

A-39

Page 368

Serial Commands 4 = Ethernet TCP Port 1 5 = Ethernet TCP Port 2 Daisy Chain ID Status Serial Cmd: Default: Options:

<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 0 = Disabled 0 = Disabled 1 = Enabled

Daisy Chain ID Serial Cmd: Default: Options:

A-40

<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 1/ One or two ASCII characters.

FIS-6801 Industrial Scanner User’s Manual

Page 369

Appendices

Read Cycle Trigger / Trigger Filter Duration Serial Trigger Character External Trigger State End of Read Cycle Decodes Before Output Multisymbol Serial Trigger Start Character Serial Trigger Stop Character Capture Mode Capture Time Store No Read Image Image Processing Timeout Number of Symbols in Field of View

<K200,trigger mode,leading edge trigger filter duration,trailing edge trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,mode,read cycle timeout> <K221,number before output> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K241,mode,number of captures,rapid capture mode> <K242,time before first capture,time between 1-2,time between 2-3,time between 3-4,time between 4-5,time between 5-6,time between 6-7,time between 7-8> <K244,image storage type,image storage mode> <K245,image processing timeout> <K518,number of symbols in field of view>

Trigger Mode / Filter Duration Trigger Mode Serial Cmd: Default: Options:

<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 0 = Continuous Read 0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data and Edge

Leading Edge Trigger Filter Serial Cmd: Default: Options:

<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 313 (~10 ms) 1 to 65535 (x 32.0 µs)

Trailing Edge Trigger Filter Serial Cmd: Default: Options:

<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 313 (~10 ms) 1 to 65535 (x 32.0 µs)

Serial Trigger Character (Delimited) Serial Cmd: Default:

<K201,serial trigger character> Space (0x20)

FIS-6801 Industrial Scanner User’s Manual

A-41

Page 370

Serial Commands Options:

Any 7-bit ASCII character

External Trigger State Serial Cmd: Default: Options:

<K202,active state> 1 = Positive 0 = Negative

1 = Positive

End of Read Cycle End of Read Cycle Mode Serial Cmd: Default: Options:

<K220,end of read cycle,read cycle timeout> 0 = Timeout 0 = Timeout 1 = New Trigger 2 = Timeout or New Trigger 3 = Last Frame 4 = Last Frame or New Trigger

Read Cycle Timeout Serial Cmd: Default: Options:

<K220,end of read cycle,read cycle timeout> 100 (x10 ms = 1 second) 1 to 65535

Decodes Before Output Decodes Before Output Serial Cmd: Default: Options:

<K221,decodes before output,mode> 1 1 to 255

Mode Serial Cmd: Default: Options:

<K221,decodes before output,mode> 0 = Non-Consecutive 0 = Non-Consecutive 1 = Consecutive

Multisymbol Number of Symbols Serial Cmd: <K222,number of symbols,multisymbol separator> Default: 1 Options: 1 to 100 Multisymbol Separator Serial Cmd: <K222,number of symbols,multisymbol separator> Default: , (comma) A-42

FIS-6801 Industrial Scanner User’s Manual