Page 351
Appendices Capture Time Store No Read Image Image Processing Timeout Number of Symbols in Field of View Configuration Database Number of Active Indexes
<K242,time before first capture,time between 1-2,time between 2-3,time between 3-4,time between 4-5,time between 5-6,time between 6-7,time between 7-8> <K244,image storage type,image storage mode> <K245,image processing timeout> <K518,number of symbols in field of view>
<K252,number of active indexes,sort database> <K255,index,shutter speed,gain,focal distance,sub-sampling,row Configuration Database (Standard FIS- pointer,column pointer,row depth,column width,symbol type,morphology 6801) operation,morphology size> <K255,index,shutter speed,gain,unused,sub-sampling,row Configuration Database (FIS-6801 C-Mount) pointer,column pointer,unused,column width,unused,unused,unused> Load Current Setting from Configuration <K255–,index> Database Request Database Index Setting <K255?,index> Request All Database Settings <K255?> <K256,switch mode,frame count/time,image process looping, Database Mode image dimensions> Symbologies Composite <K453,symbology status,separator status,separator> Aztec <K458,status> Micro QR Code <K459,status> <K460,postal type,POSTNET status, PLANET status,USPS4CB Postal Symbologies status,POSTNET allow B and B’ fields,Australia Post allow 0 FCC> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol Code 39 length,full ASCII set> <K471,status,start/stop match status,start/stop output status, Codabar large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, Interleaved 2 of 5 symbol length 1,symbol length 2,guard bar,range mode status> <K473,UPC status,EAN status,supplementals status,separator UPC/EAN status,separator character,supplementals type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN status,output format,application record separator status, Code 128 / EAN 128 application record separator character,application record brackets, application record padding> Code 93 <K475,status,fixed symbol length status,fixed symbol length> <K476,status,unused,fixed symbol length status,fixed symbol PDF417 length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar Pharmacode count,bar width mode,direction,fixed threshold value,background> <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC Data Matrix 080 status,ECC 100 status,ECC 140 status,ECC 120 status> QR Code <K480,status>
FIS-6801 Industrial Scanner User’s Manual
A-23
Page 352
Serial Commands BC412 DataBar Omnidirectional DataBar Limited DataBar Expanded MicroPDF417 Camera Setup Window of Interest Focus Distance Illumination (Standard FIS-6801 Only) Camera Settings Sub-Sampling Morphological Pre-Processing Morphological Operations External Illumination Mode I/O Parameters
<K481,status,check character output,fixed symbol length status, fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,unused,fixed length status,fixed symbol length> <K516,row pointer,column pointer,row depth,column width> <K525,focal distance,distance units,lens type> <K539,mode,brightness> <K541,shutter speed,gain> <K542,sub-sampling> <K550,status> <K551,unused,operation,size> <K553,mode>
<K529,gain,shutter speed,focus position,symbol type,window of interest framing,window of interest margin> Calibration Options (FIS-6801 C-Mount) <K529,gain,shutter speed,unused,symbol type,unused,unused> <K701,serial command echo status, serial command beep status, Serial Verification control/hex output> Beeper <K702,status> Quality Output <K704,quality output separator, decodes per trigger status> Symbol Data Output <K705,symbol data output status, when to output symbol data> Read Duration Output <K706,status,separator> Global Symbol Quality Output <K708,quality output separator,output mode> <K709,symbol contrast,print growth,axial non-uniformity,unused ISO/IEC 16022 Parameters ECC> <K710,percent cell damage,total read time,capture time,locate Data Matrix Grading time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> No Read Message <K714,status,message> Input 1 <K730,input mode,active state> Frame Information <K734,output frame number,output coordinates> ISO/IEC 16022 Grade LED Display <K737,unused,LED AIM LED display> Green Flash LED <K750,LED status,targeting status,green flash duration> Status Indicators <K751,comm,bar graph,I/O 1,I/O 2> <K757,status,port,image mode,image format,image quality, EZ Trax Output object info enable,grade enable> Database Identifier Output <K759,status,separator character> <K770,global status,default on power-on,load configuration database, EZ Button save for power-on> EZ Button Modes <K771,first beep,second beep,third beep,fourth beep>> Calibration Options (Standard FIS-6801)
A-24
FIS-6801 Industrial Scanner User’s Manual
Page 353
Appendices Trend Analysis Output 1 Trend Analysis Output 2 Trend Analysis Output 3 Diagnostics Output 1 Diagnostics Output 2 Diagnostics Output 3 Symbol Quality Output 1
Symbol Quality Output 2
Symbol Quality Output 3 Output 1 Parameters Output 2 Parameters Output 3 Parameters Matchcode Matchcode Master Symbol Database Size New Master Pin Master Symbol Match Replace Mismatch Replace Diagnostics Hours Since Reset (Read-only) Service Message User-Defined Name Output Format Format Extract Format Insert Format Assign Output Format Status Output Filter Configuration Output Filter Enable
<K780,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K790,unused,service unit> <K791,unused,service unit> <K792,unused,service unit> <K800,Output on Symbol Contrast,Symbol Contrast Threshold, Output on Print Growth,Print Growth Threshold,Output on Axial Non-Uniformity,Axial Non-Uniformity Threshold,Output on Unused ECC,Unused ECC Threshold> <K801,Output on Symbol Contrast,Symbol Contrast Threshold, Output on Print Growth,Print Growth Threshold,Output on Axial Non-Uniformity,Axial Non-Uniformity Threshold,Output on Unused ECC,Unused ECC Threshold> <K802,Output on Symbol Contrast,Symbol Contrast Threshold, Output on Print Growth,Print Growth Threshold,Output on Axial Non-Uniformity,Axial Non-Uniformity Threshold,Output on Unused ECC,Unused ECC Threshold> <K810,output on,output state,pulse width,output mode> <K811,output on,output state,pulse width,output mode> <K812,output on,output state,pulse width,output mode> <K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K231,index,master symbol data> <K735,status,replacement string> <K736,status,replacement string> <K407> (returns: hours,minutes) <K409,status,service message, threshold,resolution> <K412,user-defined name> <K740,output index,start location,length> <K741,output index,length,hex string> <K742,symbol number,status> <K743,output format status> <K744,filter number,symbology,length,wildcard,placeholder, data,unused,database index> <K745,number of filters>
FIS-6801 Industrial Scanner User’s Manual
A-25
Page 354
Serial Commands
Serial Command Format wenglor readers are controlled by two types of serial commands: configuration commands and utility commands.
Rules that apply to both configuration and utility commands • Less than ‘<‘ and greater than ‘>’ angle bracket characters enclose the commands. • Commands and data are case sensitive. Characters must be entered as upper or lower case, as specified.
Serial Utility Commands Serial Utility Commands are sent during operations and are not followed by <A> or <Z>.
Serial Configuration Commands (K Commands) wenglor’s serial configuration commands begin with a single “K” character followed by a 3digit numeric character, comma-separated command fields, and an initializing command, as follows: <Knumeric character,data,data,...etc.><initializing command> An initializing command <Z> or <A> may follow the command. • <Z> initializes the Scanner’s memory and saves for power-on. • <A> initializes the Scanner’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K473,1><Z>. To change Baud Rate and reset without saving changes for power-on, send <K100,3><A>.
Serial Configuration Command Conventions • All command fields (except the last) must be followed by a comma (without a space). • NULL cannot be used. The characters <, >, and , can be used, but only if entered as hex pairs (see ASCII Character Entry Modifier). • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <K100,4,1,0,0> can be entered as <K100,,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate only, send <K100,3>.
A-26
FIS-6801 Industrial Scanner User’s Manual
Page 355
Appendices
Concatenating Configuration Commands Commands can be concatenated (added together) in a single string. For example, <K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Quiet Zone, and resets the data buffers without saving the changes for power-on.
Serial Command Status Request To ensure that any command was received and accepted, send the Show Reader Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark. For example, send <K142?> to request the status of Postamble.
Entering Control Characters in Serial Commands To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CNTL-m CNTL-j>
FIS-6801 Industrial Scanner User’s Manual
A-27
Page 356
Serial Commands
Serial Configuration Commands The following serial commands can be entered through ESP’s Terminal to control FIS6801 functions. Detailed descriptions of command parameters are available in Parameters.
Communication RS-232 A RS-232 B RS-422 Ethernet Ethernet TCP Ports Search and Configure Mode RS-232 A Data Type RS-232 B Data Type RS-422 Data Type Ethernet TCP Port 1 Data Type Ethernet TCP Port 2 Data Type Preamble Postamble Response Timeout LRC Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Protocol Selection External Data Routing Array Communication Modes
<K100,baud rate,parity,stop bits,data bits> <K101,status,baud rate,parity,stop bits,data bits> <K102,status,baud rate,parity,stop bits,data bits> <K126,status,IP address,subnet,gateway,IP address mode> <K127,TCP Port 1,TCP Port 2> <K128,ESP Search and Configure Mode> <K130,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K131,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K132,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K133,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K134,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K141,status,preamble> <K142,status,postamble> <K143,response timeout> <K145,status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K160,protocol,address,protocol port> <K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> <K162,mode,source,daisy chain i.d. status,daisy chain i.d.>
RS-232 A Baud Rate, RS-232 A Serial Cmd: Default: Options:
A-28
<K100,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 3 = 4800 4 = 9600 6 = 38.4K 7 = 57.6K 9 = 230K
2 = 2400 5 = 19.2K 8 = 115.2K
FIS-6801 Industrial Scanner User’s Manual
Page 357
Appendices Parity, RS-232 A Serial Cmd: Default: Options:
<K100,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even
2 = Odd
Stop Bits, RS-232 A Serial Cmd: Default: Options:
<K100,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two
Data Bits, RS-232 A Serial Cmd: Default: Options:
<K100,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight
RS-232 B Status, RS-232 B Serial Cmd: Default: Options:
<K101,status,baud rate,parity,stop bits,data bits> 1 = Enabled 0 = Disabled 1 = Enabled
Baud Rate, RS-232 B Serial Cmd: Default: Options:
<K101,status,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19.2K 6 = 38.4K 7 = 57.6K 8 = 115.2K 9 = 230K
Parity, RS-232 B Serial Cmd: Default: Options:
<K101,status,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even 2 = Odd
Stop Bits, RS-232 B Serial Cmd: Default: Options:
<K101,status,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two
Data Bits, RS-232 B Serial Cmd:
<K101,status,baud rate,parity,stop bits,data bits>
FIS-6801 Industrial Scanner User’s Manual
A-29
Page 358
Serial Commands Default: Options:
1 = Eight 0 = Seven
1 = Eight
RS-422 Status, RS-422 Serial Cmd: Default: Options:
<K102,status,baud rate,parity,stop bits,data bits> 0 = Disabled 0 = Disabled 1 = Enabled
Baud Rate, RS-422 Serial Cmd: Default: Options:
<K102,status,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19.2K 6 = 38.4K 7 = 57.6K 8 = 115.2K 9 = 230K
Parity, RS-422 Serial Cmd: Default: Options:
<K102,status,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even 2 = Odd
Stop Bits, RS-422 Serial Cmd: Default: Options:
<K102,status,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two
Data Bits, RS-422 Serial Cmd: Default: Options:
<K102,status,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight
Ethernet Serial Cmd: Default: Options:
<K126,status,IP address,subnet,gateway,IP address mode> 1 = Enabled 0 = Disabled 1 = Enabled
IP Address Serial Cmd: Default: Options: A-30
<K126,status,IP address,subnet,gateway,IP address mode> 192.168.0.100 0.0.0.0 – 255.255.255.255 FIS-6801 Industrial Scanner User’s Manual
Page 359
Appendices Subnet Serial Cmd: Default: Options:
<K126,status,IP address,subnet,gateway,IP address mode> 255.255.0.0 0.0.0.0 – 255.255.255.255
Gateway Serial Cmd: Default: Options:
<K126,status,IP address,subnet,gateway,IP address mode> 0.0.0.0 0.0.0.0 – 255.255.255.255
IP Address Mode Serial Cmd: Default: Options:
<K126,status,IP address,subnet,gateway,IP address mode> 1 = DHCP 0 = Static 1 = DHCP
Ethernet TCP Ports TCP Port 1 Serial Cmd: Default: Options:
<K127,TCP Port 1,TCP Port 2> 2001 1024 – 65535
TCP Port 2 Serial Cmd: Default: Options:
<K127,TCP Port 1,TCP Port 2> 2003 1024 – 65535
RS-232 A Data Type Symbol Data Output, RS-232 A Serial Cmd: Default: Options:
<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Extra Symbol Information, RS-232 A Serial Cmd: Default: Options:
<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Diagnostic Output, RS-232 A Serial Cmd:
<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode>
FIS-6801 Industrial Scanner User’s Manual
A-31
Page 360
Serial Commands Default: Options:
1 = Enabled 0 = Disabled
1 = Enabled
External Source Processing Mode, RS-232 A Serial Cmd: Default: Options:
<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data
RS-232 B Data Type Symbol Data Output, RS-232 B Serial Cmd: Default: Options:
<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Extra Symbol Information, RS-232 B Serial Cmd: Default: Options:
<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Diagnostic Output, RS-232 B Serial Cmd: Default: Options:
<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
External Source Processing Mode, RS-232 B Serial Cmd: Default: Options:
<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data
RS-422 Data Type Symbol Data Output, RS-422 Serial Cmd: Default: Options:
A-32
<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
FIS-6801 Industrial Scanner User’s Manual