Page 341

Appendices

Optoisolated Outputs The reader has optoisolated outputs that can transfer signals from the reader to peripherals. Outputs can be configured as either NPN or PNP, but NPN and PNP cannot be mixed in a system, because the output common is shared by all outputs.

NPN Output for Host Input

NPN Output for External Load

FIS-6801 Industrial Scanner User’s Manual

A-13

Page 342 read from a scan by OCR; it may hold reading errors

Electrical Specifications

PNP Output for Host Input

Reader Host +V Output 1 Input 0, _ p' Output 2 4h Input > = Pp Output 3 - - > Input, »> P Output Common © oe > a A-14 FIS-6801 Industrial Scanner User’s Manual

Page 343 read from a scan by OCR; it may hold reading errors

PNP Output for External Load

Reader

Output 1 4 tp, >

Load

Output 2 + tp

Load

Output 3 co wa f°

| poutput Common

Load

FIS-6801 Industrial Scanner User’s Manual

Appendices

A-15

Page 344

Electrical Specifications

Optoisolated Inputs All discrete inputs are optoisolated. Inputs can be configured as either NPN or PNP, but NPN and PNP cannot be mixed in a system, because the input common is shared by all inputs.

NPN

A-16

FIS-6801 Industrial Scanner User’s Manual

Page 345 read from a scan by OCR; it may hold reading errors

Appendices

PNP Source PNP we Reader, - a q a | CLC | , Trigger wt © vy © +; ) - @® New Master * q ) - e - " CLC v Sy ; Ei + - T - + Input 1 va o - CLC vali D + ¥ Sy _m, ~ - ® | Input Common |. GND

CLC = Current Limiting Circuit

FIS-6801 Industrial Scanner User’s Manual A-17

Page 346 read from a scan by OCR; it may hold reading errors

Electrical Specifications Output Wiring

M12 12-pin plug flying lead cordset Terminal Strip Light Stack

‘

Output 1 Pin 5 Gray * Red Beacon

Output 2. Pin 11, - - - - - - - Grray/Pink ® Amber Beacon

Output 3 Pin6 Pink 2 Green Beacon

24V+ Pin 2, - - - - - oO 24V+ Input Common Pin 8, - - - - - - - - Red New Master Pin 4 Yellow 2 ) Normally Open

Momentary Push Button (New Master)

Output Common Pin 12, - - - - - - 4 ) Ground Pin 7, - - - - Blue

A-18 FIS-6801 Industrial Scanner User’s Manual

Page 347

Appendices

Appendix C, Ground and Shield Considerations Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.

FIS-

An earth ground is provided through the cable shields and chassis of the Scanner.

Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, Scanner, and their power supplies are connected to a common earth ground.

FIS-6801 Industrial Scanner User’s Manual

A-19

Page 348

Ground and Shield Considerations

Expected Power and Ground Connections for Proper Operation

Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the Scanner. • “Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.

A-20

FIS-6801 Industrial Scanner User’s Manual

Page 349

Appendices

Appendix D, Flying Lead Cordset Pinouts wenglor offers flying leads cordsets - ZAS13Rx01 - for use in FIS-6801 hardware configurations. The diagrams below show the correspondence of wire colors to pins.

ZAS13Rx01 Connection Line M12×1; 12-Pin Socket, Flying Leads The 61-000167-01 cordset connects to FIS-6801 Connectors A, and ZAA12NN01 Connectors 1 and 3.

FIS-6801 Industrial Scanner User’s Manual

A-21

Page 350

Serial Commands

Appendix E, Serial Commands Note: For a list of utility commands such as defaults, read rate requests, device control options, and Scanner status requests, see Serial Utility Commands. Communication RS-232 A RS-232 B RS-422 Ethernet Ethernet TCP Ports Search and Configure Mode RS-232 A Data Type RS-232 B Data Type RS-422 Data Type Ethernet TCP Port 1 Data Type Ethernet TCP Port 2 Data Type Preamble Postamble Response Timeout LRC Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Protocol Selection External Data Routing Array Communication Modes Read Cycle Trigger / Trigger Filter Duration Serial Trigger Character External Trigger State End of Read Cycle Decodes Before Output Multisymbol Serial Trigger Start Character Serial Trigger Stop Character Capture Mode

A-22

<K100,baud rate,parity,stop bits,data bits> <K101,status,baud rate,parity,stop bits,data bits> <K102,status,baud rate,parity,stop bits,data bits> <K126,status,IP address,subnet,gateway,IP address mode> <K127,TCP Port 1,TCP Port 2> <K128,ESP Search and Configure Mode> <K130,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K131,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K132,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K133,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K134,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K141,status,preamble> <K142,status,postamble> <K143,response timeout> <K145,status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K160,protocol,address,protocol port> <K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> <K162,mode,source,daisy chain i.d. status,daisy chain i.d.> <K200,trigger mode,leading edge trigger filter duration,trailing edge trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,mode,read cycle timeout> <K221,number before output> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K241,mode,number of captures,rapid capture mode>

FIS-6801 Industrial Scanner User’s Manual