Page 331

Appendices Light Collection Options Progressive scan, square pixel. Shutter: Software-adjustable 1/60 to 1/100,000; CMOS (WVGA): 752 x 480 pixels Laser Light (Standard FIS-6801FIS-6801) Type: Laser diode Output Wavelength: 655 nm nominal Operating Life: 50,000 hours @ 25° C Safety Class: Visible laser: Class 1

Protocols Point-to-Point, Point-to-Point with RTS/CTS, Point-to-Point with XON/XOFF, Point-to-Point with RTS/CTS and XON/XOFF, Multidrop, Daisy Chain, User-Defined Multidrop, Ethernet TCP/IP, EtherNet/IP Electrical Standard FIS-6801 CMOS Power Requirement: 5-28VDC, 200 mV p-p max ripple, 135 mA at 24VDC (typ.) Discrete I/O Input 1/Trigger/New Master: Bi-directional, Optoisolated, 4.5–28V rated (13 mA at 24VDC); New Master is (–) to signal ground Outputs (1, 2, 3): Bi-directional, Optoisolated, 1–28V rated (ICE < 100 mA at 24VDC, current limited by user)

FIS-6801 Industrial Scanner User’s Manual

A-3

Page 332

General Specifications Safety Certifications CDRH, FCC, UL/cUL (Listed, UL60950 4K68), CE, CB, BSMI (compliant)

RoHS/WEEE Compliant ISO 9001 Registered Company

©2011 wenglor sensoric gmbh All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.

A-4

FIS-6801 Industrial Scanner User’s Manual

Page 333

Appendices

ZAA12NN01 Connection Box Mechanical Height: .75" (19.1 mm) Width: 2.50" (83.5 mm) Depth: 3.15" (80 mm) Weight: 7 oz. (200 g)

ZAA12NN01 Dimensions

FIS-6801 Industrial Scanner User’s Manual

A-5

Page 334

General Specifications

Read Ranges Note: Ranges correspond to specific symbol element sizes, and range increases as element size increases. Modular Zoom Optics: Inches (mm) Narrow Bar Width

15°

1D

2D

0.0033 (0.08)

0.005 (0.13)

0.0075 (0.19)

Depth of Field

Outside Edge

Inside Edge

1.9 to 5 (48 to 127)

0.75 (19)

1.5 (39)

0.2 (6)

0.4 (10)

0.010 (0.25)

1.8 to 8 (46 to 203)

0.71 (18)

2.3 (58)

0.4 (10)

1 (25)

0.015 (0.38)

0.020 (0.51)

1.7 to 9 (44 to 229)

0.71 (18)

2.5 (64)

0.5 (13)

3 (76)

0.035 (0.89)

0.050 (1.27)

3 to 9.7 (76 to 247)

1.02 (26)

3 (75)

0,6 (15)

4 (101)

Narrow Bar Width 2D

0.0033 (0.08)

0.005 (0.13)

30° 0.0075 (0.19)

Read Range

Field of View

Depth of Field

Outside Edge

Inside Edge

Outside Edge

1 to 3 (25 to 76)

0.83 (21)

1.8 (46)

0.4 (10)

0.8 (20)

0.010 (0.25)

1 to 6.5 (25 to 165)

0.83 (21)

3.5 (89)

0.8 (20)

1.8 (46)

0.015 (0.38)

0.020 (0.51)

1 to 16 (25 to 406)

0.83 (21)

8.3 (211)

2 (51)

8.5 (216)

0.035 (0.89)

0.050 (1.27)

2 to 32 (51 to 813)

1.3 (33)

16.4 (417)

3 (76)

21.5 (546)

1D

2D

0.0075 (0.19)

0.010 (0.25)

0.015 (0.38) 0.035 (0.89)

(using autofocus)

Outside Edge

Inside Edge

Narrow Bar Width

A-6

Field of View Inside Edge

1D

45°

Read Range (using autofocus)

Read Range (using autofocus)

Field of View

Depth of Field

Inside Edge

Outside Edge

Inside Edge

Outside Edge

1 to 5 (25 to 127)

1.3 (33)

4.1 (104)

1.5 (38)

2 (51)

0.020 (0.51)

1 to 9.5 (25 to 241)

1.3 (33)

7.5 (191)

2 (51)

6 (152)

0.050 (1.27)

1 to 23.5 (25 to 597)

1.3 (33)

18.3 (465)

3.8 (97)

19 (483)

FIS-6801 Industrial Scanner User’s Manual

Page 335 read from a scan by OCR; it may hold reading errors

Read Ranges (cont.)

f a A a iT a), [ Field of \, - Read Range, - - - - - >

Appendices

Read Area bows of Field =)

5 2. a o m va o, _>

FIS-6801 Industrial Scanner User’s Manual

Outside Edge 4, - Fj i

A-7

Page 336

General Specifications

FIS Options FIS-6801-0110G FIS-6801-1110G FIS-6801-0210G FIS-6801-1210G FIS-6801-0310G FIS-6801-1310G

A-8

FIS-6801, Industrial Scanner, CMOS, 15 Degree Optic, Serial FIS-6801, Industrial Scanner, CMOS, 15 Degree Optic, Ethernet FIS-6801, Industrial Scanner, CMOS, 30 Degree Optic, Serial FIS-6801, Industrial Scanner, CMOS, 30 Degree Optic, Ethernet FIS-6801, Industrial Scanner, CMOS, 45 Degree Optic, Serial FIS-6801, Industrial Scanner, CMOS, 45 Degree Optic, Ethernet

FIS-6801 Industrial Scanner User’s Manual

Page 337

Appendices

FIS-6801 Industrial Scanner User’s Manual

A-9

Page 338

Electrical Specifications

Appendix B, Electrical Specifications Standard FIS-6801 Power Requirement

CMOS Power Requirement: 5-28VDC, 200 mV p-p max ripple, 135 mA at 24VDC (typ.)

FIS-6801 Connectors

A is a serial M12 12-pin plug. It is the same for all models of the FIS-6801. B is a serial M12 12-pin socket for serial models and an Ethernet M12 8-pin socket for Ethernet models. Output 2 New Master

Default Power

Output 1

RS-232 (Host) TxD

Output 3

Trigger Ground RS-232 (Host) RxD

Input Common Output Common

A (All Models) M12 12-pin Plug Pin 1 2 3 4 5 6 7 8 9 10 11 12

Function Trigger Power Default New Master Output 1 Output 3 Ground Input Common RS-232 (Host) RxD RS-232 (Host) TxD Output 2 Output Common

Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue

Continued next page

A-10

FIS-6801 Industrial Scanner User’s Manual

Page 339

Appendices

FIS-6801 and ZAA12NN01 Connectors and Pinouts (continued) RS-422/485 RxD (–) Input Common

RS-232 TxD/ RS-232 RTS Trigger

Ground

RS-232 RxD/ RS-232 CTS

RS-422/485 RxD (+)

Power

RS-422/485 TxD (+)

Terminated Terminated

RX (–)

RX (+) Terminated

Input 1

Terminated

RS-422/485 TxD (–)

Function Trigger Power Terminated Input 1 Port 3 422/485 TxD (+) Port 3 422/485 RxD (+) Ground Input Common Port 2 TxD/Port 1 RTS Port 2 RxD/Port 1 CTS Port 3 422/485 TxD (–) Port 3 422/485 RxD (–)

TX (–) Terminated

B (Serial Models) M12 12-pin Socket Pin 1 2 3 4 5 6 7 8 9 10 11 12

TX (+)

Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue

FIS-6801 Industrial Scanner User’s Manual

B (Ethernet Models) M12 8-pin Socket Pin 1 2 3 4 5 6 7 8

Function Terminated Terminated Terminated TX (–) RX (+) TX (+) Terminated RX (–)

A-11

Page 340

Electrical Specifications

ZAA12NN01 Connectors Connector T on the ZAA12NN01 Interface Device is the Trigger connector. Connectors 1, 2, and 3 can be used to bus power and data as required by the application. The connectors on the ZAA12NN01 interface device physically mirror those on the FIS-6801 Scanner, but they do not have explicit pin assignments. The ZAA12NN01 connectors take on the communications and power roles that are assigned to them. Trigger

Ground

+10-28V

Trigger/New Master / Input 1 Common

ZAA12NN01 Trigger Connector 4-pin Socket

1 +10-28V 2 Trigger / New Master / Input 1 Common 3 Ground 4 Trigger

Power Switch Trigger Switch

ZAA12NN01 Wiring Diagram

Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin socket. All three connectors can be assigned to bus power and data. The two switches at the center of the device allow the user to route signals as needed. The simple diagram above (also shown on the base of the ZAA12NN01) illustrates how power, communications, I/O, and trigger signal can be routed through the ZAA12NN01 device. Power can be bussed between Scanners and interface devices. At each location on a network where a new power supply is added, the Power switch on the ZAA12NN01 can be used to break power between Connector 2 and Connectors 1, 3, and T. The Trigger signal between Connector 2 and Connectors 1, 3, and T can be broken using the Trigger switch. This isolates trigger signals as required.

A-12