Page 321
Utilities
Learn Operations Learn Sending the <LEARN> command from ESP’s Terminal will put the Scanner into a mode of operation that will cause it to “learn” the next Data Matrix symbol decoded. This mode of operation will remain active until either a Data Matrix symbol is decoded or the call is made to disable the mode and revert back to normal operation. Upon decoding a Data Matrix symbol, the image processing will save pertinent information regarding the target symbol to allow it to be processed more quickly and consistently. The data collected by the Learn operation can be saved for a Power-On condition by sending the <Z> command.
Unlearn Sending the <UNLEARN> command will cause the Scanner to discard any information acquired during a Learn operation. The Unlearn state can be saved for a Power-On condition by sending the <Z> command.
Learn Status Sending the <LEARN?> request will return the current status of Learn operations. Responses are sent in this format: <LEARN,0> (Default; symbol has not been learned.) <LEARN,1> (Learn operation in progress.) <LEARN,2> (Symbol has been learned.)
Learn Persistence The learn state and parameters persist in the same way as ordinary parameters. Examples: • A FIS-6801 in a Learned state has not been saved. Cycling power will remove any Learned state information and the Scanner will power-on in its configured state. • A FIS-6801 is saved in a Learning state. The Scanner will power-on in the Learning state and will learn the first Data Matrix symbol decoded. • A FIS-6801 is saved in a Learned state. The Scanner will power-on in the Learned state and will only decode the learned symbol type. • A FIS-6801 in a Learned state is issued a reset default command <Ard>. The unit will return to an Unlearned state but if power is cycled it will return to its saved state.
FIS-6801 Industrial Scanner User’s Manual
7-29
Page 322
Reboot System
Reboot System Sending a <reboot> command from ESP’s Terminal will “cold-reboot” the system, starting from Boot Code.
7-30
FIS-6801 Industrial Scanner User’s Manual
Page 323
Utilities
Static Validation Sending a <VAL> command from ESP’s Terminal will cause the Scanner to perform a static validation operation and will output validation results to the Terminal.
Output Screen Data Matrix validation information is output in the format below in response to the <VAL> command. Note: If the Scanner fails to decode the Data Matrix symbol, a No Read message is displayed.
Validation Parameters Symbol Contrast Usage: Definition:
Lets the user know if contrast settings are less than acceptable. All the pixels that fall within the area of the test symbol, including its required zone, will be sorted by their reflectance values to select the darkest 10% and the lightest 10% of the pixels. The arithmetic mean of the darkest and the lightest pixels is calculated and the difference of the two means is the Symbol Contrast. (ANSI) Symbol Contrast grading is defined this way: A (4.0) if SC ? 70% B (3.0) if SC ? 55% C (2.0) if SC ? 40% D (1.0) if SC ? 20% F (0.0) if SC ? 20%
FIS-6801 Industrial Scanner User’s Manual
7-31
Page 324
Static Validation
Print Growth Definition:
The extent to which dark or light markings appropriately fill or exceed their module boundaries. These values are determined by counting pixels in the clock pattern of the binary digitized image, then comparing it to a nominal value and minimum and maximum values. The grade is defined in this way: A (4.0) if -.050 ? PG ? 0.50 B (3.0) if -.070 ? PG ? 0.70 C (2.0) if -.085 ? PG ? 0.85 D (1.0) if -.100 ? PG ? 1.00 F (0.0) if PG < -1.00 or PG > 1.00
Axial Non-Uniformity (Data Matrix Only) Definition:
Axial non-uniformity is a measure of how much the sampling point spacing differs from one axis to another, namely AN = abs (XAVG - YAVG) / ((XAVG + YAVG)/2) where abs ( ) yields the absolute value. If a symbology has more than two major axes, then AN is computed for those two average spacings which differ the most. The grade is defined in this way: A (4.0) if AN ? .06 B (2.0) if AN ? .08 C (2.0) if AN ? .10 D (1.0) if AN ? .12 F (0.0) if AN ? .12
Unused Error Correction (Data Matrix Only) Definition:
7-32
The correction capacity of Reed-Solomon decoding is expressed in the equation: e + 2d ? d - p where e is the number of erasures, t is the number of errors, d is the number of error correction codewords, and p is the number of codewords reserved for error detection. The Unused Error Correction parameter tests the extent to which regional or spot damage in the symbol has eroded the decoding safety margin that error correction provides. The grade is defined in this way: A (4.0) if UEC ? .62 B (3.0) if UEC ? .50 C (2.0) if UEC ? .37 D (1.0) if UEC ? .25 F (0.0) if UEC ? .25
FIS-6801 Industrial Scanner User’s Manual
Page 325
Utilities
Targeting Activate Targeting System Sending a <l1> command (lower-case L and numeral 1) from ESP’s Terminal activates the Scanner’s targeting system. Important: <l1> is not supported by the FIS-6801 C-Mount Scanner.
De-activate Targeting System Sending a <l0> command (lower-case L and numeral 0) de-activates the Scanner’s targeting system. Important: <l0> is not supported by the FIS-6801 C-Mount Scanner.
FIS-6801 Industrial Scanner User’s Manual
7-33
Page 326
Y-Modem Transfer Options
Y-Modem Transfer Options Y-Modem Upload <uy,path and image file name> Note: There are only three scales available from the Scanner. The three scales are full, quarter, and eighth. The Directory response will read out the image dimensions. To receive the image, request to download by the reported dimensions. If quarter-scaled or eighth-scaled images are required, then divide the dimensions by 4 or by 8 and request by the reduced dimensions. (1.) Directory (None assumes root) / (Root Directory) /saved (Saved Directory) (2.) Image Status Good/ (IP decoded a symbol) No Read/ (IP did not decode a symbol) Mismatch/ (IP decoded the wrong symbol) Pending/ (Not run through IP) (3.) Age 0 to n n = Max Images (8 ? Max) (4.) Image Name (Full-Scale) 1280 x 1024.bmp 1280 x 1024_gs.bmp 1280 x 1024.jpg 1280 x 1024_q(1-100).jpg Valid Scales (Depends on Full Dimensions) 1280 x 1024 (Full) 320 x 256 (Quarter - divide by 4) 160 x 128 (Eighth - divide by 8) (5.) Type .bmp (Bitmap image - no loss of resolution) .jpg (JPEG image - loss of resolution with compression) JPEG Compression Quality (1-100%) _q1.jpg _q100.jpg Examples: <uy,/saved/noread/2/320x256_gs.bmp> <uy,/saved/noread/2/320x256_q33.jpg>
7-34
FIS-6801 Industrial Scanner User’s Manual
Page 327
Utilities
Y-Modem Download (Code) <dy,key> Key app.bin dsp.bin ker.bin
Note: The “key” field only accepts app.bin, dsp.bin, or ker.bin.
FIS-6801 Industrial Scanner User’s Manual
7-35
Page 328
Y-Modem Transfer Options
7-36
FIS-6801 Industrial Scanner User’s Manual
Page 329
Appendices Contents Appendix A General Specifications .............................................................................................. A-2 Appendix B Electrical Specifications .......................................................................................... A-11 Appendix C Ground and Shield Considerations......................................................................... A-20 Appendix D Flying Lead Cordset Pinouts................................................................................... A-22 Appendix E Serial Commands ................................................................................................... A-23 Appendix F Protocol Commands................................................................................................ A-78 Appendix G ASCII Table ............................................................................................................ A-87 Appendix H Configuring Ethernet TCP/IP .................................................................................. A-88 Appendix I Using EtherNet/IP..................................................................................................... A-91 Appendix J Allen-Bradley PLC Setup....................................................................................... A-100 Appendix K Interface Standards............................................................................................... A-121 Appendix L Glossary of Terms ................................................................................................. A-122
FIS-6801 Industrial Scanner User’s Manual
A-1
Page 330
General Specifications
Appendix A, General Specifications Mechanical (Standard FIS-6801) Height: 1.59" (40.5 mm) Width: 2.27" (57.6 mm) Depth: 3.79" (96.3 mm) Weight: 10 oz. (280 g) Environmental Enclosure: Die-cast aluminum, IP65/67 rated Operating Temperature: 0° to 50° C (32° to 122° F) Storage Temperature: –29° to 70° C (–20° to 158° F) Humidity: up to 90% (non-condensing) Communication Interface Standard Interfaces: RS-232, RS-422, RS-485, Ethernet CE Mark General Immunity for Light Industry: EN 55024:1998 ITE Immunity Standard Radiated and Conducted Emissions of ITE Equipment: EN 55022:98 ITE Disturbances Light Source (Standard FIS-6801) Type: High-output LEDs
Symbologies 2D Symbologies: Data Matrix (ECC 0-200), QR Code, Micro QR Code, Aztec Code Stacked Symbologies: PDF417, MicroPDF417, GS1 DataBar (Composite and Stacked) Linear Symbologies: Code 39, Code 128, BC412, Interleaved 2 of 5, UCP/EAN, Codabar, Code 93, Pharmacode, Postal Symbologies Read Parameters Pitch: ±30° Skew: ±30° Tilt: ±360° CMOS Decode Rate: Up to 60 decodes per second Focal Range: 1” (33 mm) to ? (liquid lens autofocus)
Note: Nominal dimensions shown. Typical tolerances apply.
Indicators FIS-6801 Dimensions LEDs: Read performance, power, read status, network activity, I/O Green Flash: Good Read Red X: Symbol Locator Beeper: Good Read, Match/Mismatch, No Read, serial command confirmation, On/Off
A-2