Page 311

Utilities

Request Checksum Send a request to the Scanner for application code or DSP code checksums. 1. Click the Firmware tab. 2. Select App Code or DSP Code from the dropdown menu to the left of the Request Checksum button. 3. Click the Request Checksum button to see the part number displayed in the text field to the right.

Request Checksum by Serial Command • When <!> (a request for all available firmware checksums) is sent, the Scanner returns: <!a/APP_CHECKSUM><!d/DSP_CHECKSUM><!d/CFG_CHECKSUM>. • When <!a> (a request for the application code checksum) is sent, the Scanner returns: <!a/APP_CHECKSUM>. • When <!d> (a request for the DSP code checksum) is sent, the Scanner returns: <!d/DSP_CHECKSUM>. • When <!p> (a request for the system configuration file checksum) is sent, the Scanner returns: <!d/CFG_CHECKSUM>.

FIS-6801 Industrial Scanner User’s Manual

7-19

Page 312

Firmware

Request Build Number by Serial Command Note: X = base part number; R = revision number; B = build number • When <#.> (a request for all part numbers) is sent, the Scanner returns: <#a/35-XXXXXX-RR.BBB><#b/35-XXXXXX-RR.BBB><#d/35-XXXXXX-RR.BBB> <#k/35-XXXXXX-RR.BBB><#p/35-XXXXXX-RR.BBB>. • When <#a.> (a request for the application code build number) is sent, the Scanner returns: <#a/35-XXXXXX-RR.BBB>. • When <#b.> (a request for the boot code build number) is sent, the Scanner returns: <#b/35-XXXXXX-RR.BBB>. • When <#d.> (a request for the DSP code build number) is sent, the Scanner returns: <#d/35-XXXXXX-RR.BBB>. • When <#k.> (a request for the kernel code build number) is sent, the Scanner returns: <#k/35-XXXXXX-RR.BBB>. • When <#p.> (a request for the system configuration file build number) is sent, the Scanner returns: <#p/35-XXXXXX-RR.BBB>.

7-20

FIS-6801 Industrial Scanner User’s Manual

Page 313

Utilities

FIS-6801 Industrial Scanner User’s Manual

7-21

Page 314

Bar Code Configuration Mode

Bar Code Configuration Mode Definition: Serial Cmd:

Bar Code Configuration Mode is a way of programming the Scanner by using ECC 200 Data Matrix symbols. <BCCFG>

Bar Code Configuration Mode can be entered three different ways: 1. By forcing the Scanner into Bar Code Configuration Mode by serial command <BCCFG>. 2. By configuring one of the 4 EZ Button positions to Bar Code Configuration Mode. 3. By reading a Data Matrix symbol with a special code word used by ISO/IEC 16022 to signify Scanner programming. This can be either in a regular read cycle or during a read rate test. Reading this symbol in the calibration routine will have no effect.1 Once Bar Code Configuration Mode has been entered, the Data Matrix symbols can be thought of as serial data. You can configure the Scanner by printing labels in wenglor’s serial command format. Commands are processed as if the data were streamed in through the serial port. The Scanner will acknowledge the symbol with a beep, green flash, and echo the serial data to the host. If the command causes the Scanner to produce more serial output, such as serial verification or counter requests, the data will be routed to the host port. Bar Code Configuration Mode can be exited by any reset <A> or <Z> command as well as a <J> or a quick press and release of the EZ Button. The command to exit Bar Code Configuration Mode can be included as part of the Data Matrix symbol. For example, try encoding <K200,4><K220,1><J> into a Data Matrix symbol. This configures the Scanner to enable Serial Trigger Mode, to program a new trigger to end the read cycle, and to exit Bar Code Configuration Mode with <J>. To end all EZ Button functions, press the EZ Button once and quickly release.

1. In normal reading modes, it is required to read a special Data Matrix symbol with a special codeword used by ISO/IEC 16022 to signify Scanner programming.

7-22

FIS-6801 Industrial Scanner User’s Manual

Page 315

Utilities

Calibration Sending the <@CAL> command from ESP’s Terminal initiates auto-calibration without entering the auto-calibration menu. The calibrated parameters are determined by the settings of the Calibration Options command.

Lens Calibration Important: The <@OPTIC> command should only be used when changing the lens module. Important: <@OPTIC> is not supported by the FIS-6801 C-Mount Scanner. Sending the <@OPTIC> command puts the Scanner into a setup mode for the purpose of improving the accuracy of the focal distance parameter (<K525>). The Scanner comes with a default focal curve based on unit averages. When this isn’t close enough to obtain all distances, the <@OPTIC> command can be used to start a 2-point test to normalize the focal distance and improve accuracy. This should generally be done with lenses that were not originally shipped with the Scanner. Important: <K525> is not supported by the FIS-6801 C-Mount Scanner. The table below shows the setting and test requirements to improve distance parameter accuracy. Lens Type and Command <K525,,1> (.) UHD 15° <K525,,2> (..) HD 30° <K525,,3> (…) SD 45°

Inside Test Requirements 10 mil/0.25 mm Data Matrix @ 1.0”/25 mm 10 mil/0.25 mm Data Matrix @ 1.0”/25 mm 10 mil/0.25 mm Data Matrix @ 1.0”/25 mm

FIS-6801 Industrial Scanner User’s Manual

Outside Test Requirements 30 mil/0.75 mm Data Matrix @ 10”/254 mm 30 mil/0.75 mm Data Matrix @ 10”/254 mm 30 mil/0.75 mm Data Matrix @ 10”/254 mm

7-23

Page 316

Default/Reset/Save

Default/Reset/Save

Saved for Power-On

Resets (Not Saved for Power-On)

Understanding and controlling the Scanner’s active, saved, and default settings is critical to its successful operation. Function

Serial Cmd

ESPa

EZ Button

Reset (Will not save for power-on)

<A>

Save to Reader, Send No Save

No

<Ard>

Send <Ard> from Terminal

No

<Arp>

Send <Arp> from Terminal

No

<Arc>

Send <Arc> from Terminal

No

Reset and Recall wenglor Default Parameters Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Save Current Settings for Power-On

<Z>

Save Current Settings as Customer Default Parameters for Power-On

<Zc>

Recall wenglor Default Settings and Save for Power-On (Will not default “sticky parameters”) Recall wenglor Default Settings, Default “Sticky Parameters”, and Save for Power-On Recall Customer Default Settings and Save for Power-On

Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaults for Power-Onb

No No

<Zrd>

Send <Zrd> from Terminal

No

<ZRDall>

Send <ZRDall> from Terminal

No

<Zrc>

Send <Zrc> from Terminal

Press and hold while powering on Scanner a. When right-clicking in a tree control to select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the Scanner itself, follow up with a Save to Reader, Send and Save command. b. Only available in ESP if enabled in Preferences (General tab), accessible from the Options dropdown menu.

Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.

Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled to the Scanner or the <Arp> command is issued.

Defaults Defaults are wenglor firmware settings or saved customer settings that can be recalled, either by software or hardware reset.

7-24

FIS-6801 Industrial Scanner User’s Manual

Page 317

Utilities

Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as power-on parameters but are saved in a different, isolated section of NOVRAM. This allows a user essentially to create a back-up set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or are no longer desired. It is important to note that a hardware default (jumper the default pin to ground) does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or have the capability to communicate within those settings. By first doing an EZ Button default to restore the known wenglor defaults, the user can then recall the previous customer-saved settings with an <Arc> or <Zrc> command.

Restore Customer Defaults Use the EZ Button to default the scanner by holding it down while applying power to the scanner (if this feature is enabled).

wenglor Default Parameters wenglor default parameters are contained in the firmware and cannot be changed.

Software Defaults wenglor default parameters can be recalled (loaded into current settings) with the <Ard> command or recalled and saved for power-on with the <Zrd> command.

Hardware Default If a software default and reset is not possible, it may be necessary to reset the Scanner by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds of a power-on or a reset. 1. Apply power to the Scanner. 2. Locate default pin and ground. 3. Momentarily connect the default and ground wires (or pins) and listen for a series of short beeps. 4. Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.

Default on Power-On Use the EZ Button to default the Scanner by holding it down while applying power to the Scanner (if this feature is enabled).

FIS-6801 Industrial Scanner User’s Manual

7-25

Page 318

Default/Reset/Save

7-26

FIS-6801 Industrial Scanner User’s Manual

Page 319

Utilities

Scanner Status <?> Scanner Status Request The Scanner responds to a status request <?> with a two character hex value, such as <?/ 22>. To determine status: 1. Look up the binary conversion in the table below. For example, the first hex 2 would be 0 0 1 0 in binary, as read from binary digits 3 through 0; the second hex 2 is also 0 0 1 0 as read from binary digits 7 through 4. 2. Next, enter your binary values from the table below in the “Binary” column next to the appropriate bit. Binary Bit 0 1 2 3 4 5

Binary 0 1 0 0 0 1

Scanner Status Command error detected Command received Communication error detected Flash sector unprotect failure Host/Aux port buffer overflow Scanner is in a read cycle

3. Under “Binary,” interpret 1s as true and 0s as not true. For example, bit 1 has a 1 in the “Binary” column, indicating “Command Received”. Bit 5 is also a 1, indicating that the “Scanner is in a read cycle”.

Hex Value 0 1 2 3 4 5 6 7 8 9 A B C D E F

Bit Digits 7

6

5

3

2

1

4 0

0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1

0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1

0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

<K?> All Status Request This is the fastest way to learn the Scanner’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.

<K??> All Descriptor Request This request will return all current descriptors for every K command, starting with the lowest K command value and ending with the highest K command value.

<K?#> All Range Request This request will return the current settings of all commands within the user-defined range, starting with the lowest user-defined K command value and ending with the highest user-defined K command value.

FIS-6801 Industrial Scanner User’s Manual

7-27

Page 320

Scanner Status

<Knnn?> Single Status Request This request will return the value of the variables associated with the requested K command. The request of a single entry of a database command cannot exceed the number of database slots for the specific command.

<Knnn??> Single Descriptor Request This request returns the basic functional description of all fields in the requested K command.

<Knnn?#> Single Range Request This request will return the value range and storage type description of all fields in the requested K command.

<Knnnd> Single Command Default This request will default a single K command to original factory parameters.

7-28