Page 301
Utilities
Device Control Click the Utilities button and then the Device Control tab to display the Device Control view.
The Output 1 Pulse, Output 2 Pulse, and Output 3 Pulse buttons activate the link between the + and – of the host connector. The buttons in the Extras section Disable or Enable the reader.
Device Control Serial Utility Commands Output 1 Pulse Sending <L1> activates the link between Output 1 (+) and Output 1 (–) of the host connector (regardless of Master Symbol or Output 1 status).
Output 2 Pulse Sending <L2> activates the link between Output 2 (+) and Output 2 (–) of the host connector (regardless of Master Symbol or Output 2 status).
Output 3 Pulse Sending <L3> activates the link between Output 3 (+) and Output 3 (–) of the host connector (regardless of Master Symbol or Output 3 status).
Disable Reader Sending <I> will turn the Scanner OFF, end the current read cycle, and will not allow the Scanner to enter another read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being decoded, or the Scanner is being configured. Disabling the Scanner will not affect any commands that have already been downloaded.
Enable Reader Sending <H> will turn the Scanner ON and allow it to enter read cycles. FIS-6801 Industrial Scanner User’s Manual
7-9
Page 302
Differences from Default
Differences from Default Click the Utilities button and then the Differences tab to display the Differences from Default view.
Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different than default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different than default settings.
Click Generate Barcode to display the Bar Code Dialog. Then create configuration symbols containing the required configuration commands.
Send configuration settings to the Scanner without saving by clicking Send to Reader.
Click Save As to save the report as plain text or a tab-delimited text file.
Send configuration settings to the Scanner and save in ESP by clicking Send and Save.
• To create a symbol containing any of the command settings in the table, click Generate Barcode. • To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the Scanner and save them, or Send to Reader to send the settings without saving them. Important: To use Differences from Default, connect to the Scanner and Receive Reader Settings via the Send/Recv button on the toolbar. 7-10
FIS-6801 Industrial Scanner User’s Manual
Page 303
Utilities
Master Database Click the Utilities button and then the Master Database tab to display the Master Database view.
Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.
Master Database Overview Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands. 1. Click the Master Database tab. 2. Enable Matchcode Type. 3. Set the Master Symbol Database Size. 4. Select the database index in which the master symbol will be entered. 5. Do one of the following to enter master symbol data: a. Double-click the index row to type data directly into the index. b. Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.
Loads the next symbol decoded into the selected index.
Saves the database to the ScanLoads the Scanner’s saved master symbols into ESP.
Double-click a row to enter data into popup text box.
FIS-6801 Industrial Scanner User’s Manual
7-11
Page 304
Master Database
Master Symbol Database Size Master Symbol Database Size allows the user to select 1 to 10 master symbols for the master symbol database.
Set Master Symbol Database Size here.
Important: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol # 1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5 #6 #7 #8 #9 # 10
7-12
Maximum Characters 3000 1500 1000 750 600 500 428 375 333 300
FIS-6801 Industrial Scanner User’s Manual
Page 305
Utilities
Enter Master Symbol Data Allows the user to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Enter data for 1 to 10 master symbols. Caution: If no data is entered, the existing data will be deleted. 1. Open the Utilities menu. 2. Set the number of master symbols to be created in Master Symbol Database Size. 3. Double-click on each master symbol number in the table, type master symbol data in the popup dialog that appears, and click OK. 4. When all master symbol data has been entered, click the Send Database to the Reader button.
FIS-6801 Industrial Scanner User’s Manual
7-13
Page 306
Master Database
Request Master Symbol Data Returns master symbol data for any enabled master symbols from 1 to 10. 1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.
Read Next Symbol as Master Symbol After the size of the database is set, the Scanner can read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab, 1. Select the master symbol index number in which new symbol data will be stored. 2. Click the Read Symbol into Selected Index button.
Caution: If an index with existing data is selected, that data will be overwritten by the new decoded data when this command is used.
7-14
FIS-6801 Industrial Scanner User’s Manual
Page 307
Utilities
Request New Master Status Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. Send the <NEWM> command from ESP’s Terminal. The Scanner returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.
FIS-6801 Industrial Scanner User’s Manual
7-15
Page 308
Delete Master Symbol Data Master symbol data can be deleted using ESP. 1. Click the Utilities button to access the master symbol. 2. Click the Master Database tab and double-click the symbol number to be deleted. 3. Delete text and click OK.
7-16
FIS-6801 Industrial Scanner User’s Manual
Page 309
Utilities
Firmware Click the Utilities button and then the Firmware tab to display the Firmware view.
Firmware Update Firmware Update is used to download application code to the Scanner. Application code versions are specific to the Scanner. Consult with a sales representative before downloading application code. If needed, application code can be requested from wenglor. To download application code: 1. First, be sure that the Scanner is connected to the host computer. 2. Apply power to the Scanner. 3. In the Firmware Update dropdown menu, select App Code. This will open a dialog that allows the user to browse for the application code file. 4. Navigate to where the application code file is located on the host computer. 5. Allow approximately a minute for firmware to download. As the application code begins to download, the Scanner will be silent, the LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will show when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.
FIS-6801 Industrial Scanner User’s Manual
7-17
Page 310
Firmware
Firmware Verification Request Part Number Send a request to the Scanner for application code, boot code, DSP code, or kernel code part numbers. 1. Click the Firmware tab. 2. Select App Code, Boot Code, DSP Code, or Kernel Code from the dropdown menu to the left of the Request Part No. button. 3. Click the Request Part No. button to see the part number displayed in the text field to the right.
Request Part Number by Serial Command Note: X = base part number; R = revision number • When <#> (a request for all part numbers) is sent, the Scanner returns: <#a/35-XXXXXX-RR><#b/35-XXXXXX-RR><#d/35-XXXXXX-RR><#k/35-XXXXXX-RR> <#p/Sys_Cfg_P/N><#s/SafeMode_P/N>. • When <#a> (a request for the application code part number) is sent, the Scanner returns: <#a/35-XXXXXX-RR>. • When <#b> (a request for the boot code part number) is sent, the Scanner returns: <#b/35-XXXXXX-RR>. • When <#d> (a request for the DSP code part number) is sent, the Scanner returns: <#d/35-XXXXXX-RR>. • When <#k> (a request for the kernel code part number) is sent, the Scanner returns: <#k/35-XXXXXX-RR>. • When <#p> (a request for the system configuration file part number) is sent, the Scanner returns: <#p/Sys_Cfg_P/N>. • When <#s> (a request for the SafeMode part number) is sent, the Scanner returns: <#s/SafeMode_P/N>. 7-18
FIS-6801 Industrial Scanner User’s Manual