Page 291
Terminal
Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.
Click on Next Row to see the next row of macros
Click on the first arrow here to see Add Macro or Default Macros. When macros are defaulted, the entire macro set is restored to the original macro commands.
Click on subsequent arrows to edit macros.
Click a macro button to execute it in the Terminal. If the macro is a command, it is sent to the Scanner at the same time that it is displayed.
Editing a Macro Click the arrow next to any macro and select Edit to display the following dialog:
Edit the macro value or type a new Macro Name in the text field provided and define it in the Macro Value field. Click OK to save the entry.
FIS-6801 Industrial Scanner User’s Manual
6-5
Page 292
Terminal Window Menus
Terminal Window Menus Right-click on the Terminal window to display the following menu: • Copy selected text to clipboard. • Paste from Terminal or other text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a Save As dialog. • Change Font... of text in Terminal; brings up a Font dialog. • Change Echo Font... to change typed text; brings up a Font dialog. • Enable Echo enables Echo text (typed by user). • Change Background Color of Terminal window. • Non-Printable Characters allows the user to hide non-printable characters, or to show them in Standard or Enhanced format. • Default Settings returns all the above settings to default. • Keyboard Macros allows the user to create new keyboard macro commands that can be sent from function keys (F2, F4, F5, etc.)
Terminal Dropdown Menu The dropdown Terminal menu has Capture Text, Save Current Text, Send File, Find Next, and Find Previous functions, as well as the same functions defined above. • Capture Text... allows the user to append data in real time to a text file. While in operation, the text file cannot be opened. Pause interrupts the capture flow and Stop ends the flow and opens the file. • Save Current Text... saves all text in the Terminal window to a text file. • Find Next searches for a user-defined section of text in the Terminal. • Find Previous operates in the same way as Find Next, but searches backward through Terminal text.
6-6
FIS-6801 Industrial Scanner User’s Manual
Page 293
7 Utilities Contents Serial Utility Commands ............................................................................................................... 7-2 Read Rate .................................................................................................................................... 7-4 Counters ....................................................................................................................................... 7-6 Device Control .............................................................................................................................. 7-9 Differences from Default............................................................................................................. 7-10 Master Database ........................................................................................................................ 7-11 Firmware..................................................................................................................................... 7-17 Bar Code Configuration Mode .................................................................................................... 7-21 Calibration .................................................................................................................................. 7-22 Default/Reset/Save..................................................................................................................... 7-23 Scanner Status ........................................................................................................................... 7-25 Learn Operations........................................................................................................................ 7-27 Reboot System ........................................................................................................................... 7-28 Static Validation.......................................................................................................................... 7-29 Targeting .................................................................................................................................... 7-31 Y-Modem Transfer Options ........................................................................................................ 7-32
This section explains the function and purpose of serial utility commands, which are generally performed during Scanner operation.
FIS-6801 Industrial Scanner User’s Manual
7-1
Page 294
Serial Utility Commands
Serial Utility Commands Note: For a list of all K commands, see Serial Commands. Type Bar Code Configuration Calibration
Counters
Default/Reset/Save
Command <BCCFG> <@CAL> <@OPTIC> <N> <O> <T> <U> <V> <W> <X> <Y> <A> <Ard> <Arp> <Arc> <Z> <Zc> <Zrd> <ZRDall> <Zrc>
Device Control
Firmware/Checksum
7-2
<L1> <L2> <L3> <I> <H> <#> <#a> <#b> <#d> <#k> <#s> <#.> <#a.> <#b.>
Name Enter Bar Code Configuration Calibrate Initiate Lens Calibration (Standard FIS-6801 only) No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Software Reset – Retain Current Parameters Software Reset – Recall Factory Defaults Software Reset – Recall Power-On Defaults Software Reset – Recall Customer Defaults Software Reset – Save Current Settings for Power-On Software Reset – Save Current Settings as Customer Defaults Software Reset – Recall Factory Defaults and Save for Power-On Software Reset – Recall Factory Defaults, Default “Sticky” Parameters, and Save for Power-On Software Reset – Recall Customer Defaults and Save for Power-On Programmable Output 1 Programmable Output 2 Programmable Output 3 Disable Scanner Enable Scanner Display All Part Numbers Display Application Code Part Number Display Boot Code Part Number Display DSP Code Part Number Display Kernel Code Part Number Display SafeMode Part Number Display All Firmware Build Numbers Display Application Code Build Number Display Boot Code Build Number FIS-6801 Industrial Scanner User’s Manual
Page 295
Utilities
Firmware/Checksum
Scanner Status
Learn
Master Database
Read Rate Reboot System Static Validation Targeting
Y-Modem Transfer Options
<#d.> <#k.> <!> <!a> <!d> <rb,key> <?> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <Knnnd> <LEARN> <UNLEARN> <LEARN?> <G> <Gn> <NEWM> <C> <Cp> <J> <reboot> <VAL> <l1> <l0> <uy,path and image file name> <dy,image file name> <dy,key>
FIS-6801 Industrial Scanner User’s Manual
Display DSP Code Build Number Display Kernel Code Build Number Display All Available Firmware Checksums Display Application Code Code Checksum Display DSP Code Checksum Roll Back Application Code Scanner Status Request All Status Request All Descriptor Request All Range Request Single Status Request Single Descriptor Request Single Range Request Single Command Default Initiate Learn Operation Initiate Unlearn Operation Display Learn Status Store Next Decoded Symbol to Database Index 1 Store Next Decoded Symbol to Database Index n New Master Load Status Enter Decodes/Second Test Enter Decode Percent Test Exit Decodes/Second and Decode Percent Tests Cold Boot System from Boot Code Perform Static Validation of Data Matrix Symbol Activate Targeting System (Standard FIS-6801 only) De-activate Targeting System (Standard FIS-6801 only) Y-Modem Upload Y-Modem Download (Image) Y-Modem Download (Code)
7-3
Page 296
Read Rate
Read Rate Click the Utilities button and then the Read Rate tab to display the Read Rate view.
To see the number of decodes per second, click the Decodes/sec radio button and then the Start button. To see the percentage of decodes, click the Percent radio button and then the Start button. Read Rate information is displayed in the lower portion of the Utilities view. Serial commands can also be sent to the Scanner from this screen.
To end a Read Rate test, click the Stop button (the Start button becomes a Stop button during an active Read Rate test.)
Important: When Read Rate is enabled, the Configuration Database is not active, regardless of how the Scanner is configured.
7-4
FIS-6801 Industrial Scanner User’s Manual
Page 297
Utilities
Read Rate Serial Utility Commands Enter Decodes / Second Test Sending <C> instructs the Scanner to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view. This test is very useful in aligning and positioning the Scanner during setup.
Enter Decode Percent Test Sending <Cp> instructs the Scanner to transmit the percentage of decodes and any decoded symbol data.
End Decodes / Second and Decode Percent Tests Sending <J> ends both the Percent test and the Decodes/Second test.
FIS-6801 Industrial Scanner User’s Manual
7-5
Page 298
Counters
Counters Click the Utilities button and then the Counters tab to display the Counters view.
Counter commands can be a numeric value from 00000 to 65535. After reaching the maximum numeric limit of 65535, an error message will be displayed and the counter will automatically roll over and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65536 per each rollover (the Scanner does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is cycled, or if the Scanner receives a Reset or Save command. Click the Request button to display the appropriate count or Clear to set the counter to zero.
Trigger, Good Read, No Read, and Mismatch counters can be requested and cleared simultaneously (Request All and Clear All buttons) or individually (Request and Clear buttons to the left of each item).
7-6
FIS-6801 Industrial Scanner User’s Manual
Page 299
Utilities
Counters Serial Utility Commands No Read Counter Sending <N> displays the total number of no reads that have occurred since power-on or the last No Read Counter Reset command. A <N/OVERF_nnn> will be output if the counter is overflowed (nnn represents the number of times it has been overflowed; 255 times is the maximum). Sending <N> again will return the amount by which the counter has been overflowed. Example: If the counter is at 999999999 and 3 additional counts have been captured, then <N/ERROR> will be output and the next <N> command without any new no reads will return <N/000000003>.
No Read Counter Reset Sending <O> sets the No Read Counter to 000000000.
Trigger Counter Sending <T> displays the total number of triggers that have occurred since power-on or the last Trigger Counter Reset command. A <T/OVERF_nnn> will be output if the counter is overflowed (nnn represents the number of times it has been overflowed; 255 times is the maximum). Sending <T> again will return the amount by which the counter has been overflowed. Example: If the counter is at 999999998 and 3 additional counts have been captured, then <T/ERROR> will be output and the next <T> command without any new triggers will return <T/000000002>.
Trigger Counter Reset Sending <U> sets the Trigger Counter to 000000000.
Good Read / Match Counter Sending <V> displays either (1) the total number of decodes that match the master symbol or (2) the total number of good reads. The count begins from the last power-on or Good Read / Match Counter Reset command. To count the good reads that match the master symbol, enable Matchcode. To count good reads only, disable Matchcode. This counter is always active and can be requested at any time. A <V/OVERF_nnn> will be output if the counter is overflowed (nnn represents the number of times it has been overflowed; 255 times is the maximum). Sending <V> again will return the amount by which the counter has been overflowed. Example: If the counter is at 999999997 and 3 additional counts have been captured, then <V/ERROR> will be output and the next <V> command without any new good reads or matches will return <V/000000001>.
Good Read / Match Counter Reset Sending <W> sets the Good Read / Match Counter to 000000000. FIS-6801 Industrial Scanner User’s Manual
7-7
Page 300
Counters
Mismatch Counter Sending <X> displays the total number of symbols successfully decoded that do not match the master symbol since power-on or the last Mismatch Counter Reset command. A <X/ OVERF_nnn> will be output if the counter is overflowed (nnn represents the number of times it has been overflowed; 255 times is the maximum). Sending <X> again will return the amount by which the counter has been overflowed. Example: If the counter is at 999999999 and 1 additional count has been captured, then <X/ERROR> will be output and the next <X> command without any new mismatches will return <X/000000001>.
Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to 000000000.
7-8
FIS-6801 Industrial Scanner User’s Manual