Page 281

Parameters

Match Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled.

Replacement String User-defined data string that, when enabled, replaces symbol data whenever a match occurs.

Mismatch Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled.

Replacement String User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs.

FIS-6801 Industrial Scanner User’s Manual

5-179

Page 282

Diagnostics

Diagnostics Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Diagnostics tab to display the Diagnostics tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Matchcode settings can also be sent to the Scanner from ESP’s Terminal using wenglor’s K command format. Refer to the Diagnostics section of Appendix E.

5-180

FIS-6801 Industrial Scanner User’s Manual

Page 283

Parameters

Hours Since Reset (Read-only) Used as a troubleshooting tool that can help pinpoint the cause of a reset. Records the number of hours and minutes of operation since the last system reset.

Hours 16-bit counter that increments every 60 minutes. Range: 0 to 23 hours.

Minutes 16-bit counter that increments every 60 seconds. Range: 0 to 59 minutes.

FIS-6801 Industrial Scanner User’s Manual

5-181

Page 284

Diagnostics

Service Message Status When Enabled, a Service Message of up to 128 characters is sent whenever the system detects that the service time has expired.

Service Message Allows the user to define a service message of up to 128 characters.

Threshold Allows the user to determine the length of time until the service message will be sent.

Resolution The service timer has a resolution field for setting up the timer increment. Options are increments of seconds or minutes.

5-182

FIS-6801 Industrial Scanner User’s Manual

Page 285

Parameters

User-Defined Name User-Defined Name allows the user to enter any combination of ASCII characters to identify the Scanner.

FIS-6801 Industrial Scanner User’s Manual

5-183

Page 286

Diagnostics

5-184

FIS-6801 Industrial Scanner User’s Manual

Page 287

FIS-6801

6 Terminal

Contents Terminal Window.......................................................................................................................... 6-2 Find .............................................................................................................................................. 6-3 Send ............................................................................................................................................. 6-4 Macros.......................................................................................................................................... 6-5 Terminal Window Menus.............................................................................................................. 6-6

This section describes the multiple functions of ESP’s Terminal interface.

FIS-6801 Industrial Scanner User’s Manual

6-1

Page 288

Terminal Window

Terminal Window Click this button to display the Terminal view. Copy, paste, save

Clear screen

Macros listed on this bar

Type text here to find matching text in the Terminal window.

Terminal screen

Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.

Type serial commands here.

Click on desired Macro to run.

The Terminal interface allows the user to send serial commands to the Scanner by using macros, by copying and pasting, or by typing commands in the Send text field. The Terminal also displays symbol data or information from the Scanner. Right-clicking on the Terminal screen displays a menu of additional options.

6-2

FIS-6801 Industrial Scanner User’s Manual

Page 289

Terminal

Find The Find function allows the user to enter text strings to be searched for in the Terminal. For example: 1. Type “ABC” into the Find box.

2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.

FIS-6801 Industrial Scanner User’s Manual

6-3

Page 290

Send

Send The Send function allows the user to enter serial commands and then send them to the Scanner. 1. Type the command into the Send box.

2. Press Enter. 3. Click the Send button to the left of the text field to send the command additional times.

6-4

FIS-6801 Industrial Scanner User’s Manual