Page 281
Parameters
Match Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a match occurs.
Mismatch Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs.
FIS-6801 Industrial Scanner User’s Manual
5-179
Page 282
Diagnostics
Diagnostics Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Diagnostics tab to display the Diagnostics tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Matchcode settings can also be sent to the Scanner from ESP’s Terminal using wenglor’s K command format. Refer to the Diagnostics section of Appendix E.
5-180
FIS-6801 Industrial Scanner User’s Manual
Page 283
Parameters
Hours Since Reset (Read-only) Used as a troubleshooting tool that can help pinpoint the cause of a reset. Records the number of hours and minutes of operation since the last system reset.
Hours 16-bit counter that increments every 60 minutes. Range: 0 to 23 hours.
Minutes 16-bit counter that increments every 60 seconds. Range: 0 to 59 minutes.
FIS-6801 Industrial Scanner User’s Manual
5-181
Page 284
Diagnostics
Service Message Status When Enabled, a Service Message of up to 128 characters is sent whenever the system detects that the service time has expired.
Service Message Allows the user to define a service message of up to 128 characters.
Threshold Allows the user to determine the length of time until the service message will be sent.
Resolution The service timer has a resolution field for setting up the timer increment. Options are increments of seconds or minutes.
5-182
FIS-6801 Industrial Scanner User’s Manual
Page 285
Parameters
User-Defined Name User-Defined Name allows the user to enter any combination of ASCII characters to identify the Scanner.
FIS-6801 Industrial Scanner User’s Manual
5-183
Page 286
Diagnostics
5-184
FIS-6801 Industrial Scanner User’s Manual
Page 287
FIS-6801
6 Terminal
Contents Terminal Window.......................................................................................................................... 6-2 Find .............................................................................................................................................. 6-3 Send ............................................................................................................................................. 6-4 Macros.......................................................................................................................................... 6-5 Terminal Window Menus.............................................................................................................. 6-6
This section describes the multiple functions of ESP’s Terminal interface.
FIS-6801 Industrial Scanner User’s Manual
6-1
Page 288
Terminal Window
Terminal Window Click this button to display the Terminal view. Copy, paste, save
Clear screen
Macros listed on this bar
Type text here to find matching text in the Terminal window.
Terminal screen
Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.
Type serial commands here.
Click on desired Macro to run.
The Terminal interface allows the user to send serial commands to the Scanner by using macros, by copying and pasting, or by typing commands in the Send text field. The Terminal also displays symbol data or information from the Scanner. Right-clicking on the Terminal screen displays a menu of additional options.
6-2
FIS-6801 Industrial Scanner User’s Manual
Page 289
Terminal
Find The Find function allows the user to enter text strings to be searched for in the Terminal. For example: 1. Type “ABC” into the Find box.
2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.
FIS-6801 Industrial Scanner User’s Manual
6-3
Page 290
Send
Send The Send function allows the user to enter serial commands and then send them to the Scanner. 1. Type the command into the Send box.
2. Press Enter. 3. Click the Send button to the left of the text field to send the command additional times.
6-4