The text of a manual · part 41 of 46
FIS-6801 Industrial Scanner User's Manual, pages 401 to 410
Pages 401 to 410 of 454
The original document is the PDF (7.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6801
Page 401
Appendices Data Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
NULL (0x00)
Options:
Any ASCII input in the form of a pair of hex characters
Decode Direction Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0 = Any Direction
Options:
0 = Any Direction 1 = Forward 2 = Reverse
Database Index Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0 (any index)
Options:
0 to 10
Output Filter Enable Serial Cmd: <K745,number of filters> Default:
0
Options:
0 to 10
FIS-6801 Industrial Scanner User’s Manual
A-73
Page 402
Serial Commands
Serial Utility Commands Type Bar Code Configuration Calibration
Counters
Default/Reset/Save
Command <BCCFG> <@CAL> <@OPTIC> <N> <O> <T> <U> <V> <W> <X> <Y> <A> <Ard> <Arp> <Arc> <Z> <Zc> <Zrd> <Zrc>
Device Control
Firmware/Checksum
A-74
<L1> <L2> <L3> <I> <H> <#> <#a> <#b> <#d> <#k> <#s> <#.> <#a.> <#b.> <#d.> <#k.> <!>
Name Enter Bar Code Configuration Calibrate Initiate Lens Calibration (Standard FIS-6801 only) No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Software Reset – Retain Current Parameters Software Reset – Recall Factory Defaults Software Reset – Recall Power-On Defaults Software Reset – Recall Customer Defaults Software Reset – Save Current Settings for Power-On Software Reset – Save Current Settings as Customer Defaults Software Reset – Recall Factory Defaults and Save for Power-On Software Reset – Recall Customer Defaults and Save for Power-On Programmable Output 1 Programmable Output 2 Programmable Output 3 Disable Scanner Enable Scanner Display All Part Numbers Display Application Code Part Number Display Boot Code Part Number Display DSP Code Part Number Display Kernel Code Part Number Display SafeMode Part Number Display All Firmware Build Numbers Display Application Code Build Number Display Boot Code Build Number Display DSP Code Build Number Display Kernel Code Build Number Display All Available Firmware Checksums FIS-6801 Industrial Scanner User’s Manual
Page 403
Appendices Firmware/Checksum
Scanner Status
Learn
Master Database
Read Rate Reboot System Static Validation Targeting Y-Modem Transfer Options
<!a> <!d> <rb,key> <?> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <Knnnd> <LEARN> <UNLEARN> <LEARN?> <G> <Gn> <NEWM> <C> <Cp> <J> <reboot> <VAL> <l1> <l0> <uy,path and image file name> <dy,key>
FIS-6801 Industrial Scanner User’s Manual
Display Application Code Code Checksum Display DSP Code Checksum Roll Back Application Code Scanner Status Request All Status Request All Descriptor Request All Range Request Single Status Request Single Descriptor Request Single Range Request Single Command Default Initiate Learn Operation Initiate Unlearn Operation Display Learn Status Store Next Decoded Symbol to Database Index 1 Store Next Decoded Symbol to Database Index n New Master Load Status Enter Decodes/Second Test Enter Decode Percent Test Exit Decodes/Second and Decode Percent Tests Cold Boot System from Boot Code Perform Static Validation of Data Matrix Symbol Activate Targeting System (Standard FIS-6801 only) De-activate Targeting System (Standard FIS-6801 only) Y-Modem Upload Y-Modem Download (Code)
A-75
Page 404
Protocol Commands
Appendix F, Protocol Commands Communication Protocol Command Table Protocol Command (Mnemonic displayed on menu)
Control Characters (Entered in menu or serial command)
Hex Value
Effect of Command
RES
^D
04
Reset
REQ
^E
05
Request
EOT
^D
04
Reset
STX
^B
02
Start of Text
ETX
^C
03
End of Text
ACK
^F
06
Acknowledge
NAK
^U
15
Negative Acknowledge
XON
^Q
11
Begin Transmission
XOFF
^S
13
Stop Transmission
A-76
FIS-6801 Industrial Scanner User’s Manual
Page 405
Appendices
ACK/NAK Data Flow Examples Setup 1 RES REQ STX ETX ACK NAK LRC
0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x06 0x15 disabled
Transfer 1 HOST_TX Scanner_TX
<K141,0> ‘ACK’
Transfer 2 HOST_TX Scanner_TX Scanner_TX HOST_TX
<K141?> ‘ACK’ <K141,0> ‘ACK’
Error Condition Transfer 1 Scanner_TX HOST_TX Scanner_TX HOST_TX symbol data ‘NAK’ (host rejects) symbol data (resend data) ‘ACK’ (transaction complete)
Transfer 2 HOST_TX <K141?> Scanner_TX ‘ACK’ Scanner_TX <K141,0> timeout reached... timeout reached... timeout reached... Timeout Reached transaction aborted, data is flushed
FIS-6801 Industrial Scanner User’s Manual
A-77
Page 406
Protocol Commands
Setup 2 RES REQ STX ETX ACK NAK LRC
0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x06 0x15 enabled
Transfer 1 HOST_TX Scanner_TX
<K141,0>a ‘ACK’
Transfer 2 HOST_TX Scanner_TX Scanner_TX HOST_TX
<K141?>B ‘ACK’ <K141,0>a ‘ACK’
Error Condition Transfer 1 HOST_TX Scanner_TX HOST_TX Scanner_TX
A-78
<k141,0>x (BAD LRC) ‘NAK’ <K141,0>a (GOOD LRC) ‘ACK’
FIS-6801 Industrial Scanner User’s Manual
Page 407
Appendices
Setup 3 RES REQ STX ETX ACK NAK LRC
0x00 (disabled) 0x00 (disabled) 0x28 ‘(‘ 0x29 ‘)’ 0x06 0x15 enabled
Transfer 1 HOST_TX Scanner_TX
(<K141,0>)H ‘ACK’
Transfer 2 HOST_TX Scanner_TX Scanner_TX HOST_TX
(<K141?>)k ‘ACK’ (<K141,^M>)w ‘ACK’
FIS-6801 Industrial Scanner User’s Manual
A-79
Page 408
Protocol Commands
Setup 4 RES REQ STX ETX ACK NAK LRC
0x21 ‘!’ 0x3D ‘=’ 0x28 ‘(‘ 0x29 ‘)’ 0x06 0x15 enabled
Transfer 1 HOST_TX Scanner_TX
(<K141,0>)H ‘ACK’
Transfer 2 HOST_TX Scanner_TX HOST_TX Scanner_TX HOST_TX Scanner_TX
(<K100?>)n ‘ACK’ ‘!’ (<K100,8,0,0,1>)X ‘ACK’ ‘!’
Error Condition Transfer 1 HOST_TX (<K141,0>)H Scanner_TX ‘ACK’ HOST_TX (<K100?>)n Scanner_TX ‘ACK’ HOST_TX ‘!’ Scanner_TX (<K100,8,0,0,1>)X timeout reached... Scanner_TX ‘=’ timeout reached... Scanner_TX ‘=’ timeout reached... Scanner_TX ‘=’ timeout reached... Scanner_TX ‘!’
A-80
FIS-6801 Industrial Scanner User’s Manual
Page 409
Appendices
Polling Mode Data Flow Examples Setup 1 Address RES REQ STX ETX ACK NAK LRC
0x01 (translates to) Poll Req @ ‘0x1C’, Unit Select @ ‘0x1D’ 0x04 0x05 0x02 0x03 0x06 0x15 disabled
Transfer 1 HOST_TX Scanner_TX HOST_TX Scanner_TX HOST_TX
‘RES’ ‘0x1D’ ‘REQ’ (Select Unit 1 to receive data) ‘0x1D’ ‘ACK’ (Unit responds with its address) ‘STX’ <T> ‘ETX’ ‘0x1D’ ‘ACK’ (Unit responds with its address) ‘RES’ (Terminate Transfer 2)
Transfer 2 HOST_TX Scanner_TX HOST_TX Scanner_TX
‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘ACK’ ‘RES’ (Terminate Transfer 1)
Starting with a ‘RES’ ensures a clean transaction, without “leftovers” from the previous transaction.
Error Condition 1 HOST_TX ‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) Scanner_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ HOST_TX ‘Nothing’ (Host should ‘ACK’ here) timeout reached... Scanner_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... Scanner_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... Scanner_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... Scanner_TX ‘RES’ (Terminate Transfer 1, data is flushed)
FIS-6801 Industrial Scanner User’s Manual
A-81
Page 410
Protocol Commands
Error Condition 2 HOST_TX ‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) Scanner_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ HOST_TX ‘Nothing’ (Host should ‘ACK’ here) timeout reached... Scanner_TX ‘REQ’ (Unit requests an ‘ACK’ again) HOST_TX ‘NAK’ (Host rejects data frame) (Retry Event) Scanner_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ (Unit sends again) HOST_TX ‘ACK’ (Host receives data) Scanner_TX ‘RES’ (Terminate Transfer 1)
The protocol makes 3 retry attempts before data is flushed and transfer is aborted.
A-82
FIS-6801 Industrial Scanner User’s Manual