Page 221
Parameters
Three Beeps Hold down button until three beeps are heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate (Default) Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All Scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System When the Scanner reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the Scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
FIS-6801 Industrial Scanner User’s Manual
5-119
Page 222
I/O Parameters
Four Beeps Hold down button until four beeps are heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On (Default) All Scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System When the Scanner reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the Scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
5-120
FIS-6801 Industrial Scanner User’s Manual
Page 223
Parameters
Status Indicators The FIS-6801 features an array of LEDs that indicate various aspects of Scanner activity.
Controls the operation of the MOD/ACT and NET/LNK LEDs.
Disabled When set to Disabled, the MOD/ACT and NET/LNK LEDs are always off. Note: All green and red LEDs will turn on briefly during power-on or reset to confirm that they are functioning.
PHY Activity If Ethernet is available: LNK = Solid green when transceiver is linked. ACT = Blinking green when transceiver detects Tx or Rx activity. Otherwise, for all RS232 and RS422/485 activity: LNK = Blinking green with Tx data activity. ACT = Blinking green with Rx data activity. Note: Red is never turned on.
Protocol Activity If EtherNet/IP is enabled: MOD = Module status, per EtherNet/IP specification NET = Network status, per EtherNet/IP specification Otherwise, the MOD and NET LEDs are always off.
FIS-6801 Industrial Scanner User’s Manual
5-121
Page 224
I/O Parameters
Bar Graph Read Rate, Auto Calibration, Bar Code Configuration, and Read Cycle Result all share the Bar Graph (20% – 100%) LEDs.
I/O 1 I/O 1 always shows the combined state of the discrete outputs. If any output is active, the I/O 1 LED will be on.
I/O 2 I/O 2 always shows the state of the hardware input trigger. If the trigger is active, I/O 2 will be on.
5-122
FIS-6801 Industrial Scanner User’s Manual
Page 225
Parameters
Calibration Options This command specifies the operation of the calibration feature. The default configuration is setup to perform calibration on gain, focus and symbol type. Shutter speed is disabled as the default setting, since shutter speed is more of an application specific parameter and normally should be configured by the user to meet the requirements of the application. The calibration process will optimize the gain setting for the configured shutter speed (Camera). Note: Background color (Reverse Video) is part of the calibration process, regardless of the calibration setup. After successful completion of calibration, the background color will be set to the appropriate value depending on the calibrated symbol. The mirrored image parameter is not part of the calibration process, and must be configured appropriately by the user prior to calibration (Mirrored Image).
Gain Disabled The gain is fixed and is not part of the calibration process.
Enabled The gain will be calibrated to provide the best image quality and performance.
FIS-6801 Industrial Scanner User’s Manual
5-123
Page 226
I/O Parameters
Shutter Speed Unless an application is a static setup, the shutter speed setting should be configured by the user based on their application. For dynamic applications the user should configure the shutter speed setting, so the calibration process can optimize the gain for that setting. The following table illustrates a general guide-line for shutter speed configurations for various line speeds. Note: This is a general guide line, and depends on the scanners optical configuration and symbol element size.
Don’t Calibrate The shutter speed is fixed and is not part of the calibration process.
Calibrate The shutter speed will be calibrated to provide the best image quality and performance.
Calibrate Fast Shutter The calibration process will concentrate on achieving the fastest possible shutter setting that still will still have good performance. The image quality or contrast may not be as good as what would be achieved with the “Enabled” setting. The calibration process is not designed to choose the fastest shutter speed that can decode a symbol, but rather to optimize for the fastest shutter speed that still provides good image quality.
5-124
FIS-6801 Industrial Scanner User’s Manual
Page 227
Parameters
Focus Position (Standard FIS-6801 Only) Since the focus can be configured by simply entering the target distance value from the Scanner, normally the user will configure the focus without requiring calibration. However, if it is necessary to calibrate the focus distance there are two methods to accommodate this task.
Don’t Calibrate The focus position is fixed and is not part of the calibration process.
Calibrate The focus position will be calibrated to provide the best image quality and performance. This method is a simply “Search” method that tries to identify the desired focus through a search algorithm that cycles through focus settings, with a configuration of camera settings to try and locate as quickly as possible the desired focus. This is accomplished when a symbol is decoded. Once a focus distance has been located that will successfully decode a symbol, the algorithm will fine tune the search to locate the inside and outside focal distances. The final focus distance is selected as the focus distance that is in the center of these two values. This method can be time consuming if the focus is not found on the 1st pass.
FIS-6801 Industrial Scanner User’s Manual
5-125
Page 228
I/O Parameters
Symbol Type
Don’t Calibrate Only the current symbologies enabled will be considered during the calibration process.
Calibrate Autodiscrimination is in effect during the calibration process. All symbologies readable by the product, except PDF417 and Pharmacode will be attempted during calibration. Any new symbologies successfully decode during calibration will remain enabled at the end of the process. All enabled symbologies will remain enabled. For example, assume that only Code 39 is enabled at the beginning of calibration. If a Code 128 symbol is read during calibration, then Code 128 as well as Code 39 will thereafter be enabled.
Window of Interest Framing If a WOI framing mode is enabled, when calibration begins it will set the camera WOI to a full size image. Once a symbol is decoded, the camera WOI will be zoomed in both vertically and horizontally (regardless which WOI mode is enabled) to include the symbol plus an additional margin. This is done to speed up the calibration process. When calibration completes, and is successful, then the camera WOI will be adjusted according to the mode enabled. Otherwise, the original WOI configuration will be retained.
Don’t Calibrate The Window of Interest is not modified after the completion of Calibration.
5-126
FIS-6801 Industrial Scanner User’s Manual
Page 229
Parameters
Row and Column If the calibration process is successful the Window of Interest will be modified to frame the symbol plus an addition margin area around the symbol, determined by the “WOI margin” parameter.
Row If the calibration process is successful the Window of Interest rows will be modified to horizontally frame the symbol plus an addition margin determined by the “WOI margin” parameter.
Column If the calibration process is successful the Window of Interest columns will be modified to vertically frame the symbol plus an addition margin determined by the “WOI margin” parameter.
Window of Interest Margin Sets the margin size that is applied to the calibrated label, and is specified in number of pixels. If margin causes image to exceed maximum image size, it will be reduced accordingly.
FIS-6801 Industrial Scanner User’s Manual
5-127
Page 230
I/O Parameters
Database Identifier Output Useful in tracking which database entries read which symbols.
Database Identifier Output Status
Disabled When this command is disabled, no database identifier information will be output.
Enabled When this command is enabled, the Scanner will append a two-digit number and the characters “DB” to the data output following the separator for each symbol decoded using Configuration Database. For example, if the separator is an underscore character and the second database entry reads a symbol encoded with “data capture” during the read cycle, the symbol data output will be “data capture_DB02”. If the database is not active, no identifiers will be attached to output.
Separator Character The separator character separates the symbol data from the database identifier.
5-128
FIS-6801 Industrial Scanner User’s Manual