Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status This command is useful in removing any doubt about the Scanner’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K141,1,START> is entered, the Scanner will echo back <K141,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. Host Scanner If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.
Serial Command Beep Status Used to audibly verify the acceptance and validity of a command. Causes the Scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the Scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.
FIS-6801 Industrial Scanner User’s Manual
5-109
Page 212
I/O Parameters
Control / Hex Output Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M.
5-110
FIS-6801 Industrial Scanner User’s Manual
Page 213
Parameters
EZ Trax Output EZ Trax Output Status When EZ Trax output is enabled, the Scanner will attempt to output all enabled EZ Trax options. EZ Trax will not function unless enabled.
Comm Port Selects the communication port that will be used to transfer image files.
Image Mode Determines which read cycle condition triggers image file output.
FIS-6801 Industrial Scanner User’s Manual
5-111
Page 214
I/O Parameters
Image Format Selects the format of the image output file.
JPEG Quality Sets the amount of JPEG image compression. A value of 1 represents the highest compression and lowest image quality, and 100 represents the lowest compression and highest image quality.
Object Info Output If a symbol is decoded during an image capture, the symbol type and other supplementary symbol information is also included.
5-112
FIS-6801 Industrial Scanner User’s Manual
Page 215
Parameters
Grade Output Symbol quality information will be output in the form of an abbreviated identifier for each read cycle.
FIS-6801 Industrial Scanner User’s Manual
5-113
Page 216
I/O Parameters
EZ Button
EZ Button
Serves as a master switch to enable/disable the EZ Button status. The EZ Button has four positions: Single Beep, Two Beeps, Three Beeps, and Four Beeps, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight EZ Button Modes.
5-114
FIS-6801 Industrial Scanner User’s Manual
Page 217
Parameters
EZ Button Status
Disabled When set to Disabled, the EZ Button does not function.
Enabled When selected, the EZ Button is enabled and the function of each button position is selected by the EZ Button Modes command.
Trigger When selected, the EZ Button acts as a trigger for the Scanner to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:
The read cycle endures for as long as the EZ Button is pressed, unless a timeout occurs and End of Read Cycle Mode is set to Timeout. As with External Level, External Edge allows a read cycle to be initiated by pressing the EZ Button, but unlike External Level, the read cycle ends with a good read output, a timeout, or a new trigger.
Unlatch Outputs In this configuration, the EZ Button will unlatch any logic outputs that have been latched.
Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.
FIS-6801 Industrial Scanner User’s Manual
5-115
Page 218
I/O Parameters
Default on Power-On When enabled, if the EZ Button is held down on power-on, the Scanner will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command from ESP’s Terminal.
Load Configuration Database Loads Configuration Database settings to the Scanner.
Save for Power-On Saves Scanner settings for Power-On.
5-116
FIS-6801 Industrial Scanner User’s Manual
Page 219
Parameters
EZ Button Modes Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ Button’s 4 positions from a selection of 7 modes.
Single Beep Hold down button until a single beep is heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All Scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System (Default) When the Scanner reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the Scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
FIS-6801 Industrial Scanner User’s Manual
5-117
Page 220
I/O Parameters
Two Beeps Hold down button until two beeps are heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate (Default) Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All Scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System When the Scanner reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the Scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.