Page 201

Parameters

I/O Parameters Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the I/O tab to display the I/O Parameters tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: I/O Parameters settings can also be sent to the Scanner from ESP’s Terminal using wenglor’s K command format. Refer to the I/O Parameters section of Appendix E.

FIS-6801 Industrial Scanner User’s Manual

5-99

Page 202

I/O Parameters

Symbol Data Output Symbol Data Output relates to data and should not be confused with Outputs 1, 2, and 3 listed in the Output Parameters which describe output states and functions. Useful when the host needs symbol data only under certain conditions. Defines the conditions under which decoded symbol data is transmitted to the host. Note: Symbol Data Output Status, if set to Match or Mismatch, will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.

Symbol Data Output Status Disabled It is useful when an application only needs to use the discrete outputs and can allow the Scanner to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks. When set to Disabled, the Scanner will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.)

Match Match is used in an application that requires specific symbol information and needs to sort, route, or verify based on matching the specific symbol data. When set to Match, the Scanner transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A No Read can still be transmitted if Enabled.

Mismatch Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container. With Mismatch enabled, the Scanner transmits symbol data whenever the symbol data information does NOT match the master symbol. Note: A No Read can still be transmitted if Enabled.

Good Read Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified. With Good Read enabled, the Scanner transmits symbol data on any good read regardless of Matchcode Type setting. Note: A No Read can still be transmitted if Enabled.

5-100

FIS-6801 Industrial Scanner User’s Manual

Page 203

Parameters

When to Output Symbol Data This command allows the user to choose when symbol data can be sent to the host.

As Soon As Possible As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data. Note: More than one decode might in fact be required to qualify as a good read, depending on how Decodes Before Output is set. Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded.

End of Read Cycle End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time that it is decoded. Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle

Start of read cycle Read cycle duration Host activates trigger

FIS-6801 Industrial Scanner User’s Manual

This is when host expects output

5-101

Page 204

I/O Parameters

No Read Message Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.

No Read Message Status Disabled Only symbol data is output after a read cycle.

Enabled When the Scanner is in a triggered mode, a No Read message will be appended for each failed read attempt.

Message Any combination of ASCII characters can be defined as the No Read message. Note: No Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read. No Read Message can be set to any ASCII character.

5-102

FIS-6801 Industrial Scanner User’s Manual

Page 205

Parameters

Read Duration Output Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed (obtainable based on spacing between symbols.) When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output. Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days’ worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration.

Separator User-defined character that separates the symbol information from the Read Duration Output.

FIS-6801 Industrial Scanner User’s Manual

5-103

Page 206

I/O Parameters

Output Indicators

The FIS-6801 has a beeper and two LED arrays, as follows: 1. An array of green LEDs projected from the front of the Scanner that can be programmed to flash in response to user-defined conditions. 2. An array of status LEDs on the side of the Scanner.

Green Flash Mode

Used as a visual verification that a good read has occurred. An array of green LEDs in the front of the Scanner can be programmed to flash in response to user-defined conditions.

Disabled Green flash LEDs are disabled.

Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs.

5-104

FIS-6801 Industrial Scanner User’s Manual

Page 207

Parameters

Static Presentation Static Presentation Mode is used in conjunction with Continuous Read mode. When operating in Static Presentation Mode, the red LEDs will illuminate while the Scanner is searching for a symbol in Continuous Read mode. When a symbol is placed in the field of view and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the Scanner is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration.

Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a good read.

Mismatch Same as Match, except that LEDs will illuminate on a mismatch.

Strobe The green flash will be used as an illumination strobe for image capture. If it is required that the green flood is the only illumination for image capture then the internal illumination LED’s can be disabled.

FIS-6801 Industrial Scanner User’s Manual

5-105

Page 208

I/O Parameters

Targeting

Always Off The targeting LEDs remain off.

On Only When Not In Read Cycle The targeting LEDs illuminate while the Scanner is not in a read cycle. When a read cycle is entered the targeting LEDs will turn off, they will come back on upon exiting.

On Only When In Read Cycle The targeting LEDs illuminate upon entering a read cycle, and will turn off upon exiting the read cycle.

Always On The targeting LEDs are always illuminated.

Green Flash Duration Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value.

5-106

FIS-6801 Industrial Scanner User’s Manual

Page 209

Parameters

Beeper An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. Note: The beeper will also sound at any of the following times: • When the Scanner is defaulted. • When a Send and Save command is sent from ESP. • At the conclusion of an Auto Calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent from ESP’s Terminal.

FIS-6801 Industrial Scanner User’s Manual

5-107

Page 210

I/O Parameters

LED Configuration When the Symbol Grade Standard is set to ISO/IEC 16022 grade and the Bar Graph is configured for Grading, this parameter determines which ISO/IEC 16022 grade to display on the LED bar graph. Using the read rate scale as reference if the ISO/IEC 16022 grade result was a grade A, all the LEDs from 20% to 100% would be illuminated. If the result was a grade F, only the 20% LED would illuminate.

ISO/IEC 16022 Grade

Final Grade LEDs represent ISO/IEC 16022 final grade. Symbol Contrast LEDs represent ISO/IEC 16022 Symbol Contrast grade. Print Growth LEDs represent ISO/IEC 16022 Print Growth grade. Axial Non-Uniformity LEDs represent ISO/IEC 16022 Axial Non-Uniformity grade. Unused ECC LEDs represent ISO/IEC 16022 Unused ECC grade.

5-108