Page 191

Parameters

POSTNET Status POSTNET is used by the United States Postal Service to direct mail. The ZIP Code or ZIP+4 Code is encoded in the symbol. Data is encoded in half-height and full-height bars, making POSTNET a “2-state” symbology. The delivery point (usually the last two digits of the address or post office box number) is also typically encoded in POSTNET symbols. If U.S. Postal and POSTNET Status are both enabled, the Scanner will decode POSTNET symbols.

PLANET Status PLANET (Postal Alphanumeric Encoding Technique) is a symbology used by the United States Postal Service to track and identify items during delivery. Each PLANET symbol is either 12 or 14 digits long, and encodes data in half-height and full-height bars, making PLANET a “2-state” symbology. The symbol always starts and ends with a full-height bar, or “guard rail”, and each individual digit is represented by a set of five bars in which two of the bars are always short. If U.S. Postal and PLANET Status are both enabled, the Scanner will decode PLANET symbols.

USPS4CB Status USPS4CB, also called Intelligent Mail, is used by the United States Postal Service to sort and track individual items as well as flats of mail. USPS4CB combines the capabilities of POSTNET and PLANET, and can encode 31 digits (65 bars). USPS4CB symbols are slightly longer than POSTNET symbols, and offer additional flexibility in choosing symbol height and width. Data is encoded in four types of bars (“states”), each of which is identified by a name and a value. This type of postal symbol is known as “4-state”. Each bar has a “tracker”, or middle section, to which an “ascender” (top section) or “descender” (bottom section) may be added. The 4-state format allows the symbol to contain more information, and makes it easier to decode. 4-state symbols can also be printed easily in a variety of media, including dot matrix, inkjet, and laser. If U.S. Postal and USPS4CB Status are both enabled, the Scanner will decode USPS4CB symbols.

FIS-6801 Industrial Scanner User’s Manual

5-89

Page 192

Symbologies

POSTNET Allow B and B’ Fields If U.S. Postal and POSTNET are enabled, and POSTNET Allow B and B’ Fields is enabled, the Scanner will allow B and B’ fields in POSTNET symbols.

Australia Post Allow 0 FCC If Australia Post is enabled, and Australia Post Allow 0 FCC is enabled, the Scanner will allow 0 FCC in Australia Post symbols.

5-90

FIS-6801 Industrial Scanner User’s Manual

Page 193

Parameters

GS1 DataBar Note: GS1 DataBar symbologies were previously known as “Reduced Space Symbology” or “RSS”.

DataBar Expanded Note: DataBar Expanded was previously known as “RSS Expanded”. Used to encode primary and supplementary data in retail point-of-sale and other applications. DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters. Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and non-stacked).

Fixed Symbol Length Status When enabled, the Scanner will check the symbol length against the symbol length field, minus the embedded check character. If disabled, any length would be considered valid.

Fixed Symbol Length Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the Scanner will recognize (this does not include start, stop, and check character characters). The Scanner ignores any symbol not having the specified length.

FIS-6801 Industrial Scanner User’s Manual

5-91

Page 194

Symbologies

DataBar Limited Note: DataBar Limited was previously known as “RSS Limited”. DataBar Limited is designed to be read by laser scanners and CCD Scanners. It is not recommended for omnidirectional slot Scanners. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.

DataBar Omnidirectional Note: DataBar Omnidirectional was previously known as “RSS-14”. Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed. DataBar-14 is a fixed symbol length symbology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. Note: Where appropriate, use 1 (non-stacked) for better performance instead of 2 (stacked; decode both stacked and non-stacked).

5-92

FIS-6801 Industrial Scanner User’s Manual

Page 195

Parameters

PDF417 Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single symbol with multiple fields of information that will be read at several stations along the way, without reference to a database. A two-dimensional, multi-row (3 to 90), continuous, variable-length symbology that has high data capacity (up to 2,700 numeric characters, 1,800 printable ASCII characters, or 1,100 binary characters per symbol). Each symbol character consists of 4 bars and 4 spaces in a 17-module structure.

Note: Sending <a1> from ESP’s Terminal will cause PDF417 data to be prefaced with information consisting of error correction level (ECC Level n), number of rows (n Rows), number of columns (n Columns), number of informative code words (n Info Code Words) and the number of data characters (n Data Characters). This feature can be disabled by re-sending <a1>.

Fixed Symbol Length Status When Enabled, the Scanner will reject any PDF417 symbol that does not match the Fixed Symbol Length.

Fixed Symbol Length Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The Scanner will ignore any symbol not having the specified length.

Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.

FIS-6801 Industrial Scanner User’s Manual

5-93

Page 196

Symbologies

Codeword Collection

Single Image The Scanner will attempt to decode the PDF417 symbol only from the information provided in a single image.

Multiple Image The Scanner will process codewords from multiple images within the same read cycle and combine them to decode a single PDF417 symbol.

5-94

FIS-6801 Industrial Scanner User’s Manual

Page 197

Parameters

MicroPDF417 Used for labelling small items that need large data capacity. A variant of PDF417, a very efficient and compact stacked symbology that can encode up to 250 alphanumeric characters or 366 numeric characters per symbol.

Fixed Symbol Length Status When Enabled, the Scanner will reject any MicroPDF417 symbol that does not match the Fixed Symbol Length.

Fixed Symbol Length Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the MicroPDF417 symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The Scanner will ignore any symbol not having the specified length.

Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.

FIS-6801 Industrial Scanner User’s Manual

5-95

Page 198

Symbologies

Aztec Code Used in document imaging, railway ticket validation, and some postal applications. A 2D matrix symbology built on a square grid with a square “bull’s-eye” pattern at the center. Aztec Code can encode up to 3,832 numeric or 3,067 alphabetical characters, or 1,914 bytes of data. The level of Reed-Solomon error correction used with Aztec Code is configurable, from 5% to 95% of the total data region. The recommended error correction level is 23% of symbol capacity plus codewords.

Disabled The Scanner will not attempt to decode Aztec symbols.

Enabled The Scanner will attempt to decode Aztec symbols.

5-96

FIS-6801 Industrial Scanner User’s Manual

Page 199

Parameters

Composite When set to Enabled or Required, will decode the 2D composite component of a linear symbol. The linear symbol can be DataBar-14, DataBar Expanded, DataBar Limited, EAN-128, UPC-A, EAN-13, EAN-8, and UPC-E.

Enabled If Composite is set to Enabled, the Scanner will decode both the 2D composite and linear components. However, if the 2D composite component is not decoded, the linear data will be sent by itself at the end of the read cycle.

Required If set to Required, the Scanner must decode both components, or a No Read will occur.

Separator Status Allows the user to distinguish between the main and Supplemental symbols. Separates the linear and the composite component.

Separator The Separator Character will be the same as the character defined in the Multisymbol Separator field. As required by the application. Allows the user to change the separator character from a comma to a new character.

FIS-6801 Industrial Scanner User’s Manual

5-97

Page 200

Symbologies

Symbology Identifier Symbology Identifier is a standard prefix set of characters that identifies the symbol type. When enabled, the Scanner analyzes and identifies the symbology and adds a three-character identifying prefix to the data: • ] (closed bracket character) indicating the presence of a symbology identifier. • A, C, E, F, G, I, L, e, or Q • (A = Code 39; C = Code 128; E = UPC/EAN; F = Codabar; G = Code 93; I = Interleaved 2 of 5; L = PDF417 and MicroPDF417; e = GS1 DataBar (RSS); Q = Pharmacode) • Modifier Example: ]C indicates a Code 128 symbol.

Disabled When set to Disabled, symbol data output does not contain Symbology Identifier information.

Enabled When set to Enabled, symbol data output contains a Symbology Identifier sequence.

Explanation of Modifiers for Code 39, Codabar, and Interleaved 2 of 5 • For Code 39, Codabar, and Interleaved 2 of 5, the modifier indicates Check Character and Check Character Output status. • For Code 39 only, Full ASCII must be enabled to see modifiers 4, 5, and 7. Modifier

Check Character

0 1 3 4 5 7

Disabled Enabled Enabled Disabled Enabled Enabled

Check Character Output N/A Enabled Disabled N/A Enabled Disabled

Full ASCII Conversion (Code 39 Only) No No No Yes Yes Yes

Example: ]A5 indicates a Code 39 symbol with Check Character and Check Character Output enabled and Full ASCII conversion performed.

Explanation of Modifiers for Other Symbologies • For Code 128, a 1 indicates EAN 128; otherwise the modifier is 0. • For all other symbologies, the modifier is 0.

5-98