Page 181
Parameters
Check Character Output Status When this field is disabled and a check character calculation is enabled, the Scanner will strip the verified check character from the symbol data output. This condition must be accounted for if a fixed length is also being used. When enabled, the Scanner will output the check character as part of the symbol data. This condition must be accounted for if a fixed length is also being used.
FIS-6801 Industrial Scanner User’s Manual
5-79
Page 182
Symbologies
UPC/EAN Used primarily in point-of-sale applications in the retail industry. It is commonly used with wenglor Scanners in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental data following the normal symbol. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the Scanner will read UPC Version A and UPC Version E only.
EAN Status EAN is the European version of the UPC symbology and is used in European retail applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the Scanner will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN.
Note: The extra character identifies the country of origin.
5-80
FIS-6801 Industrial Scanner User’s Manual
Page 183
Parameters
Supplementals Status Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the Scanner reads supplemental code data that has been appended to the standard UPC or EAN codes.
Disabled UPC Supplementals will not be decoded.
Enabled When enabled, the Scanner will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.
Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.
Separator Status Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required.
FIS-6801 Industrial Scanner User’s Manual
5-81
Page 184
Symbologies
Separator Character As required by the application. Allows the user to change the separator character from a comma to a new character. Note: Whenever Separator Character is defined as a comma ( , ) sending a <K473,s?> command from ESP’s Terminal will return the current settings, including the separator character comma which appears after the separator status comma.
Supplementals Type As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both.
Both Either 2 character or 5 character supplementals will be considered valid.
Two Digits Only two character supplementals will be considered valid.
Five Digits Only five character supplementals will be considered valid.
5-82
FIS-6801 Industrial Scanner User’s Manual
Page 185
Parameters
UPC-E as UPC-A When disabled, the Scanner will output the version E symbols in their encoded 6-character format. When enabled, the Scanner will format the symbol as either a 12-character UPC-A symbol or an EAN-13 symbol, depending on the state of the EAN status parameter. This formatting reverses the zero suppression that is used to generate the symbol in the UPC specification.
FIS-6801 Industrial Scanner User’s Manual
5-83
Page 186
Symbologies
Code 93 Used in some clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces.
Fixed Symbol Length Status When disabled, the Scanner will accept any Code 93 symbol provided is doesn’t exceed the system’s maximum capabilities. When enabled, the Scanner will reject any Code 93 symbol that doesn’t match the fixed symbol length.
Fixed Symbol Length This is the symbol length value against which all Code 93 symbols will be compared.
5-84
FIS-6801 Industrial Scanner User’s Manual
Page 187
Parameters
Pharmacode Used mostly in pharmaceutical packaging. Encodes up to five different numbers, each with its own color, which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999,999. In binary format, each input can have up to 19 ones and zeros.
Important: When Pharmacode is enabled, other linear symbologies will not decode properly. Disable Pharmacode before reading other linear symbologies.
Fixed Symbol Length Status When enabled, the Scanner will check the symbol length against the symbol length field. If disabled, any length will be considered valid.
Symbol Length Specifies the exact number of bars that must be present for the Scanner to recognize and decode the Pharmacode symbol.
Minimum Bars Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid.
FIS-6801 Industrial Scanner User’s Manual
5-85
Page 188
Symbologies
Bar Width Status If set to Mixed, the Scanner will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the Scanner is able to tell the difference between the narrow and the wide bars.
Direction Specifies the direction in which a symbol can be read.
Fixed Threshold Value Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar.
Background Color Specifies whether the symbol will be presented on a black background or a white background.
5-86
FIS-6801 Industrial Scanner User’s Manual
Page 189
Parameters
Postal Symbologies Important: Postal Symbologies must have a pixels-per-element value of no more than 7 to be decoded reliably by the FIS-6801. The Scanner must be configured to specific read range, field of view, and camera parameters before decoding Postal Symbologies.
Position the postal symbol in the center of the Scanner’s field of view.
FIS-6801 Industrial Scanner User’s Manual
5-87
Page 190
Symbologies
Postal Symbology Type 1D Postal Symbologies are used in mail sortation, auditing, certified mail, registered mail, metered mail, and point-of-sale (POS) applications. This commend determines the postal symbology that will be decoded by the Scanner.
U.S. Postal (POSTNET, PLANET, USPS4CB) When U.S. Postal is enabled, the Scanner will only decode POSTNET, PLANET, and USPS4CB symbols. Important: POSTNET Status, PLANET Status, and USPS4CB Status are enabled by default. However, if any of the three U.S. Postal symbologies is set to disabled individually, symbols of that type will not be decoded by the Scanner even when U.S. Postal is enabled. For example, if U.S. Postal is enabled but POSTNET Status is disabled, POSTNET symbols will not be decoded by the Scanner. See POSTNET Status, PLANET Status and USPS4CB Status for more detail about U.S. Postal symbologies.
Australia Post When Australia Post is enabled, the Scanner will only decode Australia Post symbols.
Japan Post When Japan Post is enabled, the Scanner will only decode Japan Post symbols.
Royal Mail When Royal Mail is enabled, the Scanner will only decode Royal Mail symbols.
KIX When KIX is enabled, the Scanner will only decode KIX symbols.
UPU When UPU is enabled, the Scanner will decode UPU symbols and any U.S. Postal symbologies that might be enabled. For example, if Postal Symbology Type is set to UPU and POSTNET Status is enabled and, the Scanner will attempt to decode both UPU and POSTNET symbols.
5-88
FIS-6801 Industrial Scanner User’s Manual