Page 171
Parameters
Fixed Symbol Length Status When enabled, the Scanner will check the symbol length against the symbol length field. If disabled, any length will be considered valid.
Fixed Symbol Length Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the Scanner will recognize (this does not include start and stop and check character characters). The Scanner ignores any symbology that does not match the specified length.
Full ASCII Set Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) The user must know in advance whether or not to use the Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign, and percent symbol. When Full ASCII Set is enabled, the Scanner can read the full ASCII character set, from 0 to 255.
FIS-6801 Industrial Scanner User’s Manual
5-69
Page 172
Symbologies
Code 128 Code 128 is a smaller symbology useful in applications with limited space and high-security requirements. A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge.
Fixed Symbol Length Status When enabled, the Scanner will check the symbol length against the symbol length field. If disabled, any length will be considered a valid symbol.
Symbol Length Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. This specifies the exact number of characters that the Scanner will recognize (this does not include start, stop, and check character characters). The Scanner ignores any symbol not having the specified length.
5-70
FIS-6801 Industrial Scanner User’s Manual
Page 173
Parameters
EAN Status When this field is disabled, the Scanner will not check any Code 128 labels for conformance to EAN requirements, or perform any special formatting. When enabled, the Scanner can read symbols with or without a function 1 character in the first position. If a symbol has a function 1 character in the first position, it must conform to EAN format. Symbols that conform to EAN format will also be subject to the special output formatting options available in this command. If EAN status is required, the Scanner will only decode symbols that have a function 1 character in the first position and that conform to EAN format. All symbols read will be subject to the special output formatting options available in this command.
Note: Code 128 status must be enabled for EAN status to be active.
Output Format In Standard, the Scanner will not apply special EAN output formatting options. In Application, the Scanner will apply the special EAN output formatting options to decoded EAN-conforming symbols.
FIS-6801 Industrial Scanner User’s Manual
5-71
Page 174
Symbologies
Application Record Separator Status When enabled, an EAN separator will be inserted into the output between fields whenever an EAN-conforming symbol is decoded and EAN output formatting applies.
Application Record Separator Character This is an ASCII character that serves as an EAN separator in formatted EAN output.
Application Record Brackets If an EAN-conforming symbol is decoded and EAN formatting applies, this feature places bracket characters around the application identifiers in the formatted output.
Application Record Padding This feature causes the Scanner to pad variable-length application fields with leading zeroes. This is not done for the last field of a symbol.
5-72
FIS-6801 Industrial Scanner User’s Manual
Page 175
Parameters
BC412
Check Character Output Status Disabled The Scanner will strip the verified check digit from the symbol data.
Enabled The Scanner will format the verified check digit as part of the symbol data.
Fixed Symbol Length Status Disabled The Scanner will accept any length BC412 symbol as valid.
Enabled The Scanner will reject any BC412 symbol that does not match the fixed code length value for BC412.
Fixed Symbol Length The code length used to validate BC-412 symbols if the fixed code length status is set to enabled.
FIS-6801 Industrial Scanner User’s Manual
5-73
Page 176
Symbologies
Interleaved 2 of 5 Interleaved 2 of 5 has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, wenglor does not recommend this symbology for any new applications because of inherent problems such as symbol truncation. A dense, contimuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check character is highly recommended).
Check Character Status This option is not typically used, but it can be enabled for additional security in applications where the host requires redundant check character verification. An error correcting routine in which the check character character is added.
Check Character Output Status When enabled, a check character character is sent along with the symbol data for added data security.
5-74
FIS-6801 Industrial Scanner User’s Manual
Page 177
Parameters
Symbol Length 1 Useful in applications where Interleaved 2 of 5 symbols of a specific length are required. The Symbol Length 1 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. Important: If Range Mode Status is set to Disabled, the length of the symbol must match either Symbol Length 1 or Symbol Length 2 to be considered a valid symbol. If Range Mode Status is set to Enabled, Symbol Length 1 and Symbol Length 2 form a range into which the length of the symbol must fall to be considered valid.
Symbol Length 2 Useful in applications where Interleaved 2 of 5 symbols of a specific length are required. The Symbol Length 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. Important: If Range Mode Status is set to Disabled, the length of the symbol must match either Symbol Length 2 or Symbol Length 1 to be considered a valid symbol. If Range Mode Status is set to Enabled, Symbol Length 2 and Symbol Length 1 form a range into which the length of the symbol must fall to be considered valid.
Guard Bar Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding to take place. Useful when Interleaved 2 of 5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols. A guard bar is a heavy bar, at least twice the width of the wide bar, surrounding the printed Interleaved 2 of 5 symbol and helping to prevent false reads.
FIS-6801 Industrial Scanner User’s Manual
5-75
Page 178
Symbologies
Range Mode Status Important: Unless Range Mode is enabled, Symbol Length must be set to decode Interleaved 2 of 5 symbols. Useful in applications where Interleaved 2 of 5 symbols of a specific length are required. When Range Mode is disabled, the Scanner checks the value of the symbol length against the values set in Symbol Length 1 and Symbol Length 2. If the symbol length does not match either of the preset values, then it is rejected as invalid. When Range Mode is enabled, Symbol Length 1 and Symbol Length 2 are combined to form a range of valid symbol lengths. Any symbol length that does not fall into this range is rejected as an invalid symbol. Either of the preset symbol length values in the Symbol Length 1 and Symbol Length 2 fields can form the start or end of the range.
5-76
FIS-6801 Industrial Scanner User’s Manual
Page 179
Parameters
Codabar Used in photo-finishing and library applications. Previously used in medical applications, but not typically used in newer medical applications. Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths.
Start and Stop Match Status When disabled, the Scanner will decode Codabar symbols whether or not the start and stop characters are the same. When enabled, the Scanner will not decode Codabar symbols unless the start and stop characters are the same.
Start and Stop Output Status When disabled, the start and stop characters will not be present in the data output of the decoded symbol. When enabled, the start and stop characters will be present in the data output of the decoded symbol. Note: Because the start and stop characters are included as part of the data, the characters must be included as part of the length in a fixed length mode of operation.
FIS-6801 Industrial Scanner User’s Manual
5-77
Page 180
Symbologies
Large Intercharacter Gap When disabled, the spaces between characters, or the “intercharacter gap”, are ignored during the decode process. Note: If the intercharacter space is large enough to be considered a margin, the symbol will not decode, regardless of this parameter’s setting.
Fixed Symbol Length Status When disabled, the Scanner will accept any Codabar symbol provided it doesn’t exceed the system’s maximum capabilities. When enabled, the Scanner will reject any Codabar symbol that doesn’t match the fixed length.
Symbol Length This is the value against which all Codabar symbol lengths will be compared.
Check Character Type When disabled, the Scanner will not perform any character checking calculations on decoded Codabar symbols. When set to Mod 16, the Scanner will perform a modulus 16 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to NW 7, the Scanner will perform an NW7 modulus 11 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to Both, the Scanner will perform both the Mod 16 and NW7 modulus 11 check character calculations on the symbol. If the symbol does not pass either calculation, it will not be decoded.
5-78
FIS-6801 Industrial Scanner User’s Manual