Page 161

Parameters

Capture Time This command specifies the frame delays associated with the frames captured in a rapid capture mode of operation.

Time Before 1st Capture This value specifies the delay from the trigger to the first capture of any triggered read cycle.

Time Between Captures 1-2 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.

Time Between Captures 2-3 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.

Time Between Captures 3-4 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.

Time Between Captures 4-5 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.

Time Between Captures 5-6 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.

FIS-6801 Industrial Scanner User’s Manual

5-59

Page 162

Read Cycle

Time Between Captures 6-7 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.

Time Between Captures 7-8 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.

Notes for Rapid Capture, Timed Capture If rapid capture is configured for timed captures this delay is measured from the point at which the previous delay expired. If the delay expires during a previous capture the start of the capture will occur as soon as the previous capture or captures complete. For example, if rapid capture is configured for 8 captures and all delays are configured for zero all 8 captures will occur back to back as fast as the Scanner is able.

Notes for Rapid Capture, Triggered Capture If rapid capture is configured for triggered captures mode the delay taken is measured from the point at which the trigger for that capture is received. Also if an incoming trigger occurs before a previous delay has expired, the previous capture is initiated and the delay for the incoming trigger is started. Important: If the unit is triggered to capture more than 8 images the unit will repeat the last delay (8th) for the remaining frames.

5-60

FIS-6801 Industrial Scanner User’s Manual

Page 163

Parameters

Store No Read Image Image storage allows the user to store images from separate read cycles and has the ability to retrieve them later. The number of available slots for storage depends on the mode of operation. If functioning in the rapid capture mode the number of images available to store is the maximum Number of Captures – the current setting for number of captures. If the user is operating in a continuous capture mode then they can store up to the maximum number of captures – 3.

Image Storage Type Disabled / Clear Upon selection, all saved images will be cleared, and the unit will not store images for later retrieving.

Store on No Read The unit will store an image upon exiting the read cycle that retrieved a later time. If multiple captures are present during the duration of a read cycle the image stored will be the last image processed for the read cycle. This image is stored in RAM and can be retrieved as long as power is applied and the unit has not been reset via reset/save sequences. Other commands that can initialize the storage RAM are ones that changed capture modes or put the unit in a test capture mode.

Image Storage Mode First Image In this mode the image storage will store images until the available image memory has been filled. At this point the unit will stop saving additional images. In this mode you will always have the first images that were stored.

Last Image In this mode the image storage will continue to store images after the available memory has been filled by purging the oldest image in the storage memory. In this mode you will always have the last images that were stored.

FIS-6801 Industrial Scanner User’s Manual

5-61

Page 164

Read Cycle

Image Processing Settings Number of Symbols in Field of View Any Number of Symbols No limit on number of symbols attempted to decode in an image frame.

One Symbol Only one symbol will be decoded in an image frame, and this will be regardless of any qualifying attributes associated with the read cycle.

Image Processing Timeout Specifies the maximum amount of time allowed for image processing to spend on a captured image. When the time-out expires, the image processing is aborted. This time-out works in both rapid capture and continuous capture modes, as well as with the configuration database.

Notes: The time-out period does not include capture time. If a time-out occurs the image will be recorded as a No Read. This may cause some confusion because the image may decode fine given enough time.

5-62

FIS-6801 Industrial Scanner User’s Manual

Page 165

Parameters

Symbologies Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Symbologies tab to display the Symbologies tree control.

To open nested options, single-click the +.

The * indicates that the setting is the default. To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Symbologies settings can also be sent to the Scanner from ESP’s Terminal using wenglor’s K command format. Refer to the Symbologies section of Appendix E.

FIS-6801 Industrial Scanner User’s Manual

5-63

Page 166

Symbologies

Data Matrix

ECC 200 Status Disabled The Scanner will not attempt to decode ECC 200 symbols.

Enabled The Scanner will attempt to decode ECC 200 symbols.

ECC 000 Status Disabled The Scanner will not attempt to decode ECC 000 symbols.

Enabled The Scanner will attempt to decode ECC 000 symbols.

ECC 050 Status Disabled The Scanner will not attempt to decode ECC 050 symbols.

Enabled The Scanner will attempt to decode ECC 050 symbols.

ECC 080 Status Disabled The Scanner will not attempt to decode ECC 080 symbols.

Enabled The Scanner will attempt to decode ECC 080 symbols.

5-64

FIS-6801 Industrial Scanner User’s Manual

Page 167

Parameters

ECC 100 Status Disabled The Scanner will not attempt to decode ECC 100 symbols.

Enabled The Scanner will attempt to decode ECC 100 symbols.

ECC 140 Status Disabled The Scanner will not attempt to decode ECC 140 symbols.

Enabled The Scanner will attempt to decode ECC 140 symbols.

ECC 120 Status Disabled The Scanner will not attempt to decode ECC 120 symbols.

Enabled The Scanner will attempt to decode ECC 120 symbols.

ECC 130 Status Disabled The Scanner will not attempt to decode ECC 130 symbols.

Enabled The Scanner will attempt to decode ECC 130 symbols.

FIS-6801 Industrial Scanner User’s Manual

5-65

Page 168

Symbologies

QR Code

Disabled The Scanner will not attempt to decode QR Code symbols.

Enabled The Scanner will attempt to decode QR Code symbols.

5-66

FIS-6801 Industrial Scanner User’s Manual

Page 169

Parameters

Micro QR Code

Disabled The Scanner will not attempt to decode Micro QR Code symbols.

Enabled The Scanner will attempt to decode Micro QR Code symbols.

FIS-6801 Industrial Scanner User’s Manual

5-67

Page 170

Symbologies

Code 39 Code 39 is considered the standard for non-retail 1D symbology. An alphanumeric symbology with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide.

Check Character Status Enables or Disables the check character.

Check Character Output Status Check Character Output Status, when added to the symbol, provides additional data security. When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character.

Note: With Check Character Output Status enabled and an External Edge, External Level, or Serial Data trigger option enabled, an invalid check character calculation will cause a No Read Message to be transmitted at the end of the read cycle.

Large Intercharacter Gap Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. When enabled, the Scanner can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width.

Important: Do not use Large Intercharacter Gap with Narrow or Narrow, Enhanced Quiet Zone enabled, because a large intercharacter gap (over 3x) could cause a narrow quiet zone (5x) to be interpreted as an intercharacter gap. 5-68