Page 151

Parameters

Serial Data Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the field of view. It is also useful in determining if a No Read has occurred. In Serial Data, the Scanner accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger. Serial commands are entered inside angle brackets, as shown here: <n>. Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.

Serial Data and Edge Serial Data and Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be triggered manually. An auxiliary terminal can be connected to the auxiliary port so the user can send the serial trigger character through the Scanner to the host. In this mode the Scanner accepts either a serial ASCII character or an external trigger pulse to start the read cycle. Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.

Trigger Filter Duration Note: Trigger filter ranges from 32.0 µs to 2.10 seconds.

Leading Edge Used to ignore accidental triggers when Trigger Mode is set to External Edge or External Level. To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the Scanner will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the leading edge is filtered such that on an active edge, the state must be held interrupted for the trigger filter duration before a trigger will occur. Note: 313 = ~10ms.

FIS-6801 Industrial Scanner User’s Manual

5-49

Page 152

Read Cycle

Trailing Edge Used to ignore accidental triggers when Trigger Mode is set to External Edge or External Level. To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the Scanner will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the trailing edge is filtered such that on the falling edge, the state must be held for the trigger filter duration before the trigger will be deemed inactive. Note: 313 = ~10ms.

External Trigger State Allows users to select the trigger polarity that will be used in their application. Determines the active state of the trigger signal applied to the cable input of the Scanner.

5-50

FIS-6801 Industrial Scanner User’s Manual

Page 153

Parameters

Serial Trigger Allows the user to define the trigger character and delimiters that start and stop the read cycle. A serial trigger is considered an online host command and requires the same command format as all host commands. It must be entered within angle bracket delimiters < and > or, in the case of non-delimited triggers, it must define individual start and stop characters.

Character (Delimited) Allows the user to define the trigger character that initiates the read cycle. A single ASCII host serial trigger character that initiates the read cycle. A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such as < and >.

Note: Serial Data or Serial Data and Edge trigger mode must be enabled for Serial Trigger Character to function.

FIS-6801 Industrial Scanner User’s Manual

5-51

Page 154

Read Cycle

Start Character (Non-Delimited) Useful in applications where different characters are required to start a read cycle. A single ASCII host serial trigger character that starts the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Start characters can be defined and will function according to the trigger event. When defining Start trigger characters, the following rules apply: • In External Edge the Scanner looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the Scanner remains in External Level trigger read cycle until a Stop character is received. • In Serial Data and Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle.

5-52

FIS-6801 Industrial Scanner User’s Manual

Page 155

Parameters

Stop Character (Non-Delimited) Useful in applications where different characters are required to end a read cycle. A single ASCII host serial trigger character that ends the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Stop characters can be defined and will function according to the trigger event. When defining Stop trigger characters, the following rules apply: • In External Edge the Scanner looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the Scanner remains in External Level trigger read cycle until a Stop character is received. • In Serial Data and Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle.

FIS-6801 Industrial Scanner User’s Manual

5-53

Page 156

Read Cycle

Decodes Before Output Decodes Before Output specifies the number of times a symbol needs to be decoded before symbol data is output and a good read is declared.

5-54

FIS-6801 Industrial Scanner User’s Manual

Page 157

Parameters

End of Read Cycle The read cycle is the time during which the Scanner will attempt to decode a symbol. A read cycle can be ended by a timeout or a new trigger, or a combination of the two.

End of Read Cycle Mode Note: When operating in Continuous Read or Continuous Read 1 Output, the Scanner is always in the read cycle.

Timeout Typically used with Continuous Read 1 Output and Serial Data and Edge. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next symbol appears, giving the system extra time to decode and transmit the data to the host. Timeout ends the read cycle, causing the Scanner to stop reading symbols and send the symbol data or No Read message when the time set in Timeout elapses (times out), if When to Output Symbol Data is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same symbol to be read again. With External Edge, Serial Data, or Serial Data and Edge enabled, a timeout ends the read cycle and symbol data or a No Read message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger occurs or a timeout occurs. The next read cycle does not begin until the next rising edge trigger.

FIS-6801 Industrial Scanner User’s Manual

5-55

Page 158

Read Cycle

New Trigger New Trigger is an effective way to end a read cycle when objects move past the Scanner at irregular intervals (not timing-dependent). New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a rising edge trigger. With External Edge, Serial Data, or Serial Data and Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger.

Timeout or New Trigger Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular. Timeout or New Trigger is identical to Timeout except that a timeout or a new trigger (whichever occurs first) ends the read cycle.

Last Frame Useful in applications in which the timeout duration varies.

Last Frame or New Trigger Useful in applications in which line speeds are irregular and a new object could appear before the last frame in the sequence. Last Frame or New Trigger is identical to New Trigger except that a new trigger or last frame (whichever occurs first) ends the read cycle.

Read Cycle Timeout Read Cycle Timeout determines the duration of the read cycle.

5-56

FIS-6801 Industrial Scanner User’s Manual

Page 159

Parameters

Capture Mode Capture mode specifies how multiple captures are taken and managed throughout a read cycle.

Rapid Capture In a rapid capture mode one or multiple captures can taken at an interval specified by the time delay between captures parameter. In this mode the only limiting time factor is the integration and transfer timing.

Continuous Capture In continuous capture mode captures are continually taken throughout the read cycle in a multi-buffered format so that we start processing the first image while we are capturing the second. Continuous capture mode will override the pre-processing field; this improves performance in the multi-buffered format. This mode operation as laser scanners have historically operated, with captures spanning the entire read cycle duration until an exit condition occurs such as qualification or timeout.

Number of Captures Specifies the number of captures to process in the rapid capture mode. This parameter is used in conjunction with the time delay between captures parameters to specify the capture sequence of a rapid capture read cycle.

Rapid Capture Mode

FIS-6801 Industrial Scanner User’s Manual

5-57

Page 160

Read Cycle

Timed Capture Capture events are controlled by the timing values entered in the “Capture Time” command.

Triggered Capture When set to trigger captures mode the Scanner operates in the following manner: • The number of captures represents the number of triggers expected from the system per read cycle. The first trigger enters the read cycle. • Subsequent triggers initiate captures in the read cycle up to the number of captures is met or the end of read cycle condition is met. Any additional triggers between reaching the number of captures and meeting the end of read cycle requirements will be ignored. • If the read cycle is fully qualified prior to reaching the number of captures and the symbol output is set to ASAP, the symbol data will be output and all post processing (Logic outputs, video, etc.) will finish but the Scanner will remain in the read cycle. When enough triggers come in to satisfy the number of captures setting or a timeout expires, the Scanner will exit the read cycle. This operation would be synonymous with level triggered read cycle waiting for the trigger to fall. • If the end of read cycle is set for new trigger and the read cycle qualifications have not been met, the read cycle will exit upon receiving the first trigger after reaching the number of captures setting. At this time the post processing from the read cycle will complete and a new read cycle will begin.

5-58

FIS-6801 Industrial Scanner User’s Manual