Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 46

FIS-6801 Industrial Scanner User's Manual, pages 141 to 150

Pages 141 to 150 of 454

The original document is the PDF (7.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Wenglor FIS-6801

Page 141

Parameters

Daisy Chain ID The Daisy Chain ID is a two-character identifier.

FIS-6801 Industrial Scanner User’s Manual

5-39

Page 142

Communication

Daisy Chain Autoconfigure For quick setup of a daisy chain configuration. The command to Autoconfigure the daisy chain is sent to the primary Scanner and the software responds in the following ways: • Counts the number of secondary Scanners in the daisy chain. • Assigns an internal ID number (1...n) to each secondary Scanner, where the first secondary Scanner is number 1 (the primary Scanner’s ID being a 0). • Propagates the communication settings and the relevant operating modes of the primary Scanner to the ports of each secondary Scanner. • Resets each secondary Scanner. • Confirms that each secondary Scanner has acquired the new settings. When setting up a daisy chain operation, perform the following steps: 1. Set the primary Scanner (the one connected to the host) to Serial Data Trigger Mode. This will also set all the Scanners in the chain to Serial Data when the command is executed. Important: All secondary Scanners must be set to Serial Data Trigger Mode for Daisy Chain to function. Before Autoconfigure, the primary Scanner must be set to Serial (S): Host

S

Primary Scanner

S

Secondary Scanner

S

Secondary Scanner

2. Send the <K150DAISY> command from ESP’s Terminal. 3. If necessary, set the primary Scanner to External Edge. After Autoconfigure, the primary Scanner can be set to External Edge (E), but the other Scanners must remain in Serial (S): Host

E

Primary Scanner

S

Secondary Scanner

S

Secondary Scanner

Pre-Setup Requirements: 1. Start setup by matching the communication settings of the “downstream” port of the primary Scanner to the “upstream” ports of the secondary Scanners. It may be necessary to set up all the “upstream” ports first so the chain can pass information. 2. “Downstream” ports on secondary Scanners will be set up automatically during the setup process. 3. If the Scanner is Ethernet-enabled, first check to determine if RS-232 B is available. If it is available, set RS-232 B as the Source port in Array Communication Modes. Otherwise, set RS-232 A as the Source port. Port Routing for Symbol Data Output and Extra Symbol Information will be disabled on the Source port.

5-40

FIS-6801 Industrial Scanner User’s Manual

Page 143

Parameters

Preamble Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.

Preamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data

FIS-6801 Industrial Scanner User’s Manual

5-41

Page 144

Communication

Postamble Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.

Postamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data.

5-42

FIS-6801 Industrial Scanner User’s Manual

Page 145

Parameters

Read Cycle Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Read Cycle tab to display the Read Cycle tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Read Cycle settings can also be sent to the Scanner from ESP’s Terminal using wenglor’s K command format. Refer to the Read Cycle section of Appendix E.

FIS-6801 Industrial Scanner User’s Manual

5-43

Page 146

Read Cycle

Read Cycle Setup Setting up read cycle and triggering parameters involves a series of decisions based on the particular application, as follows: 1. Select the number of symbols to be read in a single cycle. 2. Decide on the trigger type to be used: if serial, choose a serial character; if external, choose either External Level or External Edge. 3. Designate how the read cycle should end (Timeout, New Trigger).

5-44

FIS-6801 Industrial Scanner User’s Manual

Page 147

Parameters

Multisymbol Multisymbol is commonly used in shipping applications where a shipping symbol contains individual symbols for part number, quantity, etc. This feature allows one trigger to pick up all the symbols. Multisymbol allows the user to define up to 100 symbols that can be read in a single read cycle. The following conditions apply: • The maximum number of characters in a read cycle is 3,000 for all symbols. • All No Read messages are posted at the end of the data string, unless output filtering is enabled. • If more than one symbol is within the field of view at the same time, symbol data may not be displayed in the order of appearance. • If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, the Scanner will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

Number of Symbols Number of Symbols is the number of different symbols that can be read in a single read cycle.

Multisymbol Separator Multisymbol Separator is used to delimit or separate data fields with a user-defined character. The Multisymbol Separator can be any valid ASCII character, inserted between each symbol read when Number of Symbols is set to any number greater than 1.

FIS-6801 Industrial Scanner User’s Manual

5-45

Page 148

Read Cycle

Trigger The Trigger is the event that initiates a read cycle. Note: When calibrating the Scanner or testing read rate, the current trigger setting will be disregarded.

Trigger Mode Continuous Read Continuous Read is useful in testing symbol readability or Scanner functions. It is not recommended for normal operations. In Continuous Read, trigger input options are disabled, the Scanner is always in the read cycle, and it will attempt to decode and transmit data for every symbol. If a single symbol stays within read range for multiple read cycles, its data will be transmitted repeatedly until it leaves the read range. The Scanner sends replies to serial commands that require responses when symbol data is transmitted, or read cycle timeout is enabled and a timeout occurs. Depending on the combination of enabled symbologies and the Threshold Mode setting, the Scanner may take longer than the timeout to process symbol data.

Note: When to Output and No Read options have no affect on Continuous Read.

5-46

FIS-6801 Industrial Scanner User’s Manual

Page 149

Parameters

Continuous Read 1 Output Continuous Read 1 Output can be useful in applications where it is not feasible to use a trigger and all succeeding symbols contain different information. It is also effective in applications where the objects are presented by hand. In Continuous Read 1 Output the Scanner self-triggers whenever it decodes a new symbol or a timeout occurs. If End of Read Cycle Mode is set to Timeout and the symbol doesn’t change, the output is repeated at the end of each timeout period. For example, if Timeout is set to one second, the Scanner sends the symbol data immediately and repeats the output at intervals of one second for as long as the symbol remains in the field of view. If End of Read Cycle Mode is set to New Trigger, the Scanner will send the current symbol data immediately, but only once. A new symbol appearing in the Scanner’s range will be read and sent immediately, provided it is not identical to the previous symbol. Caution: In automated environments, Continuous Read 1 Output is not recommended because there is typically no reliable way to verify that a symbol was missed. Note: If Trigger Mode is set to Continuous Read 1 Output, the Scanner will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

FIS-6801 Industrial Scanner User’s Manual

5-47

Page 150

Read Cycle

External Level Initiate Read Cycle: Object #1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. End Read Cycle: The same object, moving out of the detector beam, causes another change in the trigger state, which ends the read cycle.

This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the Scanner spends reading each object is not predictable. It also allows the user to determine if a No Read has occurred. External Level allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. The read cycle persists until the object moves out of the sensor range and the active trigger state changes again. Important: Level and Edge apply to the active logic state (Negative or Positive) that exists while the object is in a read cycle, between the rising edge and the falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. This applies both to External Level and External Edge.

External Edge Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. Initiate Second Read Cycle: Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a good read or timeout has not occured.

This mode is highly recommended in any application where conveying speed is constant, or if spacing, object size, or read cycle timeouts are consistent. External Edge, as with Level, allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read output, or, depending on the End of Read Cycle Mode setting, a timeout or new trigger occurs.

5-48

FIS-6801 Industrial Scanner User’s Manual