For the Wenglor FIS-6801

Page 231

Parameters

Input 1

Input Mode Determines the function of the Input pin.

Disabled When set to Disabled, the Input pin has no impact on operation.

Reset Counts When set to Reset Counts, a transition to the active state of the Input will cause the Scanner to reset the internal counters.

Unlatch Output This setting is used in combination with any of the three outputs in Latch Mode 1 (Unlatch Input # 1 Pin). A transition to the active state will clear any of the three outputs that were previously latched.

Active State

Active Open Input function is activated when input state is de-energized.

Active Closed Input function is activated when input state is energized.

FIS-6801 Industrial Scanner User’s Manual

5-129

Page 232

I/O Parameters

Output 1 Parameters Output On Output On provides discrete signalling to host software to control external devices such as PLCs and relays. It is useful for routing, sorting, and to prevent mis-packaging and mis-routing. Sets the discrete output functions for specific user-selected conditions. Allows the user to set the conditions under which an output (or outputs) will be activated. Note: If Output On is set to Match or Mismatch, a transition (switching) will not occur unless Matchcode Type is enabled and a master symbol is loaded into memory.

Mismatch or No Read Activates discrete output when the data does not match that of the master symbol or the symbol has not been decoded before the end of the read cycle.

Good Read / Match Activates a discrete output when the symbol data matches the master symbol. Note: To output on Good Read when Matchcode is not enabled, enable any output for Match.

Mismatch Activates a discrete output whenever the symbol data does not match that of the master symbol.

No Read Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle.

Trend Analysis Typically used when successful decodes are occurring but a discrete output is needed to flag a trend in quality issues. Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled.

5-130

FIS-6801 Industrial Scanner User’s Manual

Page 233

Parameters

Diagnostic Warning Typically used when a discrete indication of a diagnostic condition is needed. Activates discrete output when a diagnostic warning condition is met, depending on the diagnostic option enabled.

In Read Cycle Activates a discrete output when the Scanner is in a read cycle.

FIS-6801 Industrial Scanner User’s Manual

5-131

Page 234

I/O Parameters

Output State Sets the active electrical state of the discrete output.

Pulse Width Sets the time that the discrete output remains active.

Output Mode Sets the condition in which the discrete output is de-activated.

Pulse This is the default mode of operation in which the programmable output is activated when the Output On condition has been met and held active for the duration of the selected pulse width.

Latch Mode 1 (Unlatch Input # 1 Pin) The programmable output is activated when the Output On condition has been met and held active until the Input # 1 Pin transitions. Note: Input 1 must be set to Unlatch Output for Latch Mode 1 to function. If the Output Condition is set to Read Cycle Data Valid, then the read cycle will wait for Input 1 to unlatch the output before continuing on. This is to provide system handshake ability despite communication channel. The read cycle data must leave all channels before Read Cycle Data Valid will output. 5-132

FIS-6801 Industrial Scanner User’s Manual

Page 235

Parameters

Latch Mode 2 (Unlatch Opposite Condition) The programmable output is activated when the Output On condition has been met and held active until the opposite condition selected under Output On has been met. For example, if No Read is enabled under Output On, the programmable output will go active on a No Read and remain active until the opposite condition, a good read, occurs. If the Output Condition is set to Read Cycle Data Valid, then the read cycle will continue but every new Read Cycle Data Valid event causes the output to change state to the opposite condition. This provides a toggle event per every read cycle output. The only known outout state will be the on a power-on or reset. After reading begins, the state becomes undetermined. Only the state change itself has meaning - not the absolute value.

Latch Mode 3 (Unlatch Re-enter Read Cycle) The programmable output is activated when the Output On condition has been met and held active until a new read cycle begins. Note: All of the Output On modes are inhibited when any Diagnostic Warning is active for Output 1.

FIS-6801 Industrial Scanner User’s Manual

5-133

Page 236

I/O Parameters

Trend Analysis Note: Output On under Output 1 Parameters must be set to Trend Analysis for this output to function. Under Output 1 Parameters, expand the Trend Analysis tree. Useful in cases where the user doesn’t want to shut down for one condition but wants to monitor quality and read conditions. Applies Trend Analysis settings to Output 1. With Trend Analysis, the user can track the occurrences and frequency of mismatches, No Reads, and the number of reads per trigger, and output the results to any of three outputs. Trend Analysis Mode = No Read Trigger Evaluation Period = 25 triggers (read cycles) Number to Output On = 4 In this example, the Scanner will activate an output when 4 No Reads occur within a period of 25 triggers (read cycles).

Trend Analysis Mode Sets the trend condition (Mismatch, No Read, Decodes per Trigger, Bad Symbol, or No Symbol) that will activate the output.

Mismatch Output will be activated when the number of mismatches equals the value entered for Number to Output On within the trigger window selected in Number of Triggers. No Read Output will be activated when the number of No Reads equals the value entered for Number to Output On within the trigger window selected in Number of Triggers. Decodes per Trigger Output will be activated when the number of decodes equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

5-134

FIS-6801 Industrial Scanner User’s Manual

Page 237

Parameters

Number of Triggers The number of triggers to examine for the trend analysis condition.

Number to Output On Example: If Number to Output On is set to 3 and Trend Analysis Mode is set to No Read, then the output will not be activated until 3 No Reads have occurred. Sets the number of Trend Analysis Mode events (mismatches, No Reads, or reads/trigger as configured by Trend Analysis Mode) to occur within the trigger evaluation period before activating the associated output.

FIS-6801 Industrial Scanner User’s Manual

5-135

Page 238

I/O Parameters

Decodes per Trigger When set to this mode, and when the appropriate output is set to output on trend analysis, the Scanner will function in a Decodes per Trigger mode during the read cycle and the trend analysis operation. Output will be activated based on whether or not the symbol decode count at the end of the read cycle is less than the decodes per trigger threshold. Note: Although this setup causes the Scanner to function in a Decodes per Trigger mode, the decode count will only be appended to the symbol data if the status of the Decodes per Trigger command is enabled.

Example: Decodes per Trigger threshold: 100 100 or more decodes = No output Fewer than 100 decodes = Output fires

5-136

FIS-6801 Industrial Scanner User’s Manual

Page 239

Parameters

Symbol Quality (ISO/IEC 16022)

Output on Symbol Contrast The symbol contrast is formatted and attached to the Data Matrix symbol data as either a grade or value.

Output on Print Growth The print growth is formatted and attached to the Data Matrix symbol data as either a grade or value.

Output on Axial Non-Uniformity The axial non-uniformity is formatted and attached to the Data Matrix symbol data as either a grade or value.

Output On Unused ECC The unused ECC is formatted and attached to the Data Matrix symbol data as either a grade or value.

FIS-6801 Industrial Scanner User’s Manual

5-137

Page 240

I/O Parameters

Symbol Contrast Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Symbol Contrast grade is under the threshold.

Print Growth Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Print Growth grade is under the threshold.

Axial Non-Uniformity Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Axial Non-Uniformity grade is under the threshold.

Unused ECC Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Unused ECC grade is under the threshold.

5-138

FIS-6801 Industrial Scanner User’s Manual