The text of a manual · part 6 of 37
FIS-6300 ESD Imager User's Manual, pages 51 to 60
Pages 51 to 60 of 364
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6300
Page 51
Communications
Stop Bits, Auxiliary Port Usage: Definition: Serial Cmd: Default: Options:
Only changed if necessary to match host setting. Allows the user to select the last one or two bits in each character to indicate the end of the character. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> One 0 = One 1 = Two
Data Bits, Auxiliary Port Usage: Definition: Serial Cmd: Default: Options:
Only changed if necessary to match host setting. Number of bits in each character. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> Eight 0 = Seven 1 = Eight
FIS-6300 ESD Imager User’s Manual
3-11
Page 52
Auxiliary Port Connections
Transparent Mode Usage: Definition:
A common application, in conjunction with handheld Imagers, is one that employs an auxiliary readout to detect misapplied symbols. In Transparent Mode, data is passed between the auxiliary port and the host. The Imager buffers data from the auxiliary port and echoes the keyed data on the auxiliary port. • Auxiliary port data is passed through to the host whenever a return key is pressed at the auxiliary port or whenever symbol data is sent. If sent with symbol data, it is processed on a first-in/first-out basis. • Auxiliary port data to the host is always sent with a preamble and postamble. • If the Imager is in a polling mode with the host, auxiliary port data will still pass through. Data Originating from the Imager • Transmission to the auxiliary port occurs immediately upon a good read. • Data sent to the auxiliary port does not include a preamble or a postamble. • Communications with the auxiliary port is always in Point-to-Point protocol, even if the host is in a polled protocol mode. Data Originating from the Host • All host data is echoed to the auxiliary port in unpolled mode.
Aux. Port
Host
Imager
Aux. Port
Host
Imager
Aux. Port
Host
Imager
Serial Cmd: Options:
3-12
<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 1 = Transparent
FIS-6300 ESD Imager User’s Manual
Page 53
Communications
Half Duplex Mode Usage: Definition:
Useful when the user wants symbol data displayed on an auxiliary menu close to the Imager. In Half Duplex Mode all auxiliary port data and symbol data is sent directly to the host. Symbol data is displayed on the auxiliary port menu at the same time the data is sent to the host. Data Originating from the Auxiliary Port • Auxiliary port data to the host is ignored if the Imager is in a polled mode. • Auxiliary port data or read data is sent to the host whenever it is received. • Auxiliary port data is not echoed. • Auxiliary port data to the host is always sent without a preamble or postamble. Data Originating from the Imager • Data is transmitted to the auxiliary port at the same time it is transmitted to the host. • Data transmission conforms with all parameters specified in the configuration menu (e.g. Preamble, Postamble, End of Read Cycle).
Aux. Port
Host
Imager
Aux. Port
Host
Imager
Data Originating from the Host • All host data is echoed to the auxiliary port in unpolled mode.
Aux. Port
Host
Imager
Serial Cmd. Options:
<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 2 = Half Duplex
FIS-6300 ESD Imager User’s Manual
3-13
Page 54
Auxiliary Port Connections
Full Duplex Mode Usage: Definition:
When communication to and from the auxiliary port is required. In Full Duplex Mode all auxiliary port data and symbol data is sent directly to the host. Symbol data is not displayed on the auxiliary port menu. Data Originating from the Auxiliary Port • Auxiliary port data to the host is ignored if the Imager is in a polled mode. • Auxiliary port data or read data is sent to the host whenever it is received. • Auxiliary port data is not echoed. • Auxiliary port data to the host is always sent without a preamble or postamble.
Aux. Port
Host
Imager
Data Originating from the Imager • Data is not sent to the auxiliary port. Aux. Port
Host
Imager
Data Originating from the Host • All host data is echoed to the auxiliary port in unpolled mode.
Aux. Port
Host
Imager
Serial Cmd: Options:
3-14
<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 3 = Full Duplex
FIS-6300 ESD Imager User’s Manual
Page 55
Communications
Daisy Chain Mode Usage:
Definition:
Serial Cmd: Options: Function:
Useful in applications where: • More than one symbol type is present. • A symbol may be present on multiple sides of a package. • Symbols are presented at different depths. In a daisy chain application, Imagers are connected in tandem or a “daisy chain” and decoded data is relayed from one Imager to another until the data reaches the host. A master Imager has its host port linked to the host computer and its auxiliary port linked to the host port of the first secondary Imager in the chain. Thereafter, each secondary Imager’s auxiliary port is linked to the host port of the secondary Imager that is farther from the host in the daisy chain. Each Imager in the chain can be assigned an ID that accompanies any data that it sends. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 4 = Daisy Chain Before the master Imager times out, it checks its auxiliary port for data. It should be set to wait at least 30 mS for each secondary Imager in the daisy chain. If no data is received within the read cycle timeout, the master sends a noread message to the host. Otherwise the complete data is sent. If, for example, the master Imager is set to timeout in 120 mS, the first secondary Imager downstream might be set to 90 mS, the next to 30 mS, and so forth, thus assuring that at least 30 mS elapses between transmissions.a Daisy-chained Imagers can send a series of symbols by enabling Multisymbol and a common multisymbol separator. If the master Imager does not receive the expected number of symbols, noread messages are appended to the data string to make up the difference between the number of symbols enabled in Multisymbol and the number of symbols read. For example, a master and two secondary Imagers have Number of Symbols set to 3 and Multisymbol Separator defined as %. If the master and the first secondary Imager do not find symbols, but the next secondary Imager registers a good read, the transmitted results would be: symbol data % noread % noread a. The above example assumes a best-case scenario. Other factors, such as baud rate, dynamic focus timing, number of characters in a given symbol, and the number of secondary Imagers in the daisy chain can affect timing and may need to be included in your calculations for complete accuracy.
FIS-6300 ESD Imager User’s Manual
3-15
Page 56
Auxiliary Port Connections
Command Processing Mode Usage: Definition:
Serial Cmd: Options:
3-16
Allows a user to send configuration settings from the host port to the auxiliary port. When enabled, Command Processing Mode allows commands to be entered via the auxiliary port and direct externally triggered read cycle data in one of two ways: • Bar code data, including the serial trigger (if used), will be transmitted to the last port from which a command was sent. • If the last command came from the host port, then externally triggered read cycle data will only be output to the host port. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 5 = Command Processing
FIS-6300 ESD Imager User’s Manual
Page 57
Communications
Daisy Chain ID Status Usage: Definition: Serial Cmd: Default: Options:
Used in a daisy chain setup in cases where the host needs to know which Imager in the chain sent the data. Each Imager in a daisy chain can be assigned a one or two character ID that will appear in front of decoded data and identify its source. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status, daisy chain i.d.> Disabled 0 = Disabled 1 = Enabled
Note: Enable/disable and length must be the same in all Imagers.
Daisy Chain ID Usage: Definition: Serial Cmd:
Used in a daisy chain setup in cases where the host needs to know which Imager in the chain sent the data. A one or two character prefix which identifies the particular daisy chain Imager from which the data is being sent to the host. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.>
Default:
1/
Options:
Any one or two ASCII characters.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K101h,,,,,,,3C> For >: <K101h,,,,,,,3E> For , : <K101h,,,,,,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
FIS-6300 ESD Imager User’s Manual
3-17
Page 58
Auxiliary Port System Data Status
Auxiliary Port System Data Status Definition: Serial Cmd: Default: Options:
3-18
When enabled, system data will be routed to the Auxiliary Port. This includes decoded data and diagnostic warning messages. When disabled, system data will not be routed to the Auxiliary Port. <K146,aux port system data status> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
Page 59
Communications
Daisy Chain Autoconfigure Usage: Definition:
Serial Cmd:
For quick setup and configuration of your daisy chain network. The command to autoconfigure the daisy chain is sent to the master Imager and the software responds in the following ways: • Counts the number of secondary Imagers in the daisy chain. • Assigns an internal ID number (1...n) to each secondary Imager, where the first secondary Imager is number 1 (the master Imager’s ID being a 0). • Propagates the communications settings and the relevant operating modes of the master Imager to the host and auxiliary ports of each secondary Imager. • Resets each secondary Imager. • Verifies that each secondary Imager has acquired the new settings. <K150DAISY>
Note: All secondary Imagers must be set to Serial for Daisy Chain to function. When setting up a daisy chain operation, perform the following steps: 1. Set the master Imager (the one connected to the host) to Serial. This sets all the Imagers in the chain to Serial when the command is executed. Before Autoconfigure you must set the master Imager to Serial (S):
Host
S
Master Imager
S
Secondary Imager
S
Secondary Imager
2. Send <K150DAISY>. 3. If necessary, set the master Imager to Edge. After Autoconfigure you may set the master Imager to Edge (S), but the other Imagers must remain in Serial (S):
Host
E
Master Imager
FIS-6300 ESD Imager User’s Manual
S
Secondary Imager
S
Secondary Imager
3-19
Page 60
Response Timeout
Response Timeout Usage:
Definition: Serial Cmd: Default: Options:
3-20
Only used when a response is required from the host. While in Multidrop, if the Imager does not receive an ACK or NAK from the host after sending polled data, it will act on a fault. The Imager can be set to wait indefinitely by setting Response Timeout to zero. The time that the Imager will wait before timing out if ACK, NAK, and ETX are enabled, and a host response is expected. <K143,response timeout> 12 (in 1mS increments) 0 to 255 (A zero (0) setting causes an indefinite wait.)
FIS-6300 ESD Imager User’s Manual