Page 331
Appendices
Error Condition 2 HOST_TX ‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ HOST_TX ‘Nothing’ (Host should ‘ACK’ here) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) HOST_TX ‘NAK’ (Host rejects data frame) (Retry Event) IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ (Unit sends again) HOST_TX ‘ACK’ (Host receives data) IMAGER_TX ‘RES’ (Terminate Transfer 1)
The protocol makes 3 retry attempts before data is flushed and transfer is aborted.
FIS-6300 ESD Imager User’s Manual
A-17
Page 332
Communications Protocol
Setup 2 Address RES REQ STX ETX ACK NAK LRC
0x01 (translates to) Poll Req @ ‘0x1C’, Unit Select @ ‘0x1D’ 0x04 0x05 0x02 0x03 0x06 0x15 enabled
Transfer 1 HOST_TX IMAGER_TX HOST_TX IMAGER_TX HOST_TX
‘RES’ ‘0x1D’ ‘REQ’ (Select Unit 1 to receive data) ‘0x1D’ ‘ACK’ (Unit responds with its address) ‘STX’ <T> ‘ETX’ ‘LRC’ ‘0x1D’ ‘ACK’ (Unit responds with its address) ‘RES’ (Terminate Transfer 2)
Transfer 2 HOST_TX IMAGER_TX IMAGER_TX HOST_TX
‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘LRC’ ‘ACK’ ‘RES’ (Terminate Transfer 1)
Starting with a ‘RES’ ensures a clean transaction, without “leftovers” from the previous transaction.
Error Condition 1 HOST_TX ‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘LRC’ HOST_TX ‘Nothing’ (Host should ‘ACK’ here) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... IMAGER_TX ‘RES’ (Terminate Transfer 1, data is flushed)
A-18
FIS-6300 ESD Imager User’s Manual
Page 333
Appendices
Error Condition 2 HOST_TX ‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘LRC’ HOST_TX ‘Nothing’ (Host should ‘ACK’ here) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) HOST_TX ‘NAK’ (Host rejects data frame) (Retry Event) IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘LRC’ (Unit sends again) HOST_TX ‘ACK’ (Host receives data) IMAGER_TX ‘RES’ (Terminate Transfer 1)
Error Condition 3 HOST_TX IMAGER_TX HOST_TX (Retry Event) IMAGER_TX HOST_TX IMAGER_TX
‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘BAD LRC’ ‘NAK’ (Host rejects bad LRC data) ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘GOOD LRC’ (Unit sends again) ‘ACK’ (Host receives data) ‘RES’ Terminate Transfer 1)
The protocol makes 3 retry attempts before data is flushed and transfer is aborted.
FIS-6300 ESD Imager User’s Manual
A-19
Page 334
Communications Protocol Communications Protocol Command Table Protocol Command (Mnemonic displayed on menu)
Control Characters (Entered in menu or serial command)
Hex Value
Effect of Command
RES
^D
04
Reset
REQ
^E
05
Request
EOT
^D
04
Reset
STX
^B
02
Start of Text
ETX
^C
03
End of Text
ACK
^F
06
Acknowledge
NAK
^U
15
Negative Acknowledge
XON
^Q
11
Begin Transmission
XOFF
^S
13
Stop Transmission
A-20
FIS-6300 ESD Imager User’s Manual
Page 335
Appendices
Appendix E, ASCII Table ASCII Conversion Values Dec 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Hex 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Mne NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Ctrl ^@ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_
FIS-6300 ESD Imager User’s Manual
Dec 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
Hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
Ch SP ! “ # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
Dec 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
Hex 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
Ch @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
Dec 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
Hex 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Ch ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ D
A-21
Page 336
ASCII Table
A-22
FIS-6300 ESD Imager User’s Manual
Page 337
Appendices
Appendix F, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. In the FIS-6300 ESD Imager, selection of interface is made by pin assignment and, in the case of host communications, by software switching between RS-232 and RS-422 / RS485.
RS-232 RS-232 defines an interface between two devices such as, for example, the Imager and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422 / 485 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.
FIS-6300 ESD Imager User’s Manual
A-23
Page 338
wenglor Sensor
Appendix G, wenglor Sensor In a typical operation, an Imager will wait for symbol data only during a triggered read cycle. A read cycle is initiated by a “trigger” and can be in the form of a serial command from the host (internal trigger) or a signal from an object detector (external trigger). When an object detector (also called a sensor, package detector, etc.) is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the Imager to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before its symbol can be read. The wenglor Sensor is mounted in almost any position relative to the object as long as the object passes within range of the detector and direct or reflected light from the detector does not interfere with the Imager’s reception. As the item continues to move down the line, its symbol moves into the Imager beam and is decoded.
Object and Symbol wenglor Sensor
Object and Symbol FIS-6300 Imager
A-24
FIS-6300 ESD Imager User’s Manual
Page 339
Appendices
Appendix H, Operational Tips Cleaning The FIS-6300 ESD Imager has a hard coated window that should only be cleaned with alcohol (100% isopropyl).
Mounting When mounting the FIS-6300 ESD Imager, do not insulate the stand mount. The bottom panel is the hottest part of the Imager and metal-to-metal contact is necessary for heat dissipation.
FIS-6300 ESD Imager User’s Manual
A-25
Page 340
Glossary of Terms
Appendix I, Glossary of Terms Aberration - The failure of an optical lens to produce an exact point-to-point correspondence between the object and its resulting image. Various types are chromatic, spherical, coma, astigmatism and distortion. Absorption - The loss of light of certain wavelengths as it passes through a material and is converted to heat or other forms of energy. (-) Active Illumination - Lighting a scene with a light source coordinated with the acquisition of an image. Strobed flash tubes and pulsed lasers are examples. Ambient light - Light which is present in the environment of the imaging front end of a vision system and generated from outside sources. This light, unless used for actual scene illumination, will be treated as background noise by the vision system. Analog - A smooth, continuous voltage or current signal or function whose magnitude (value) is the information. From the word “analogous,” meaning “similar to.” Analog Gain Adjustment (AGC) - Adjustment to signal strength that seeks to maintain a constant level regardless of the range of the bar code symbol. Analog-to-Digital Converter (A/D) - A device which converts an analog voltage or current signal to a discrete series of digitally encoded numbers (signal) for computer processing. Architecture - For a vision system, the hardware organization designed for high speed image analysis. ASIC - An acronym for Application Specific Integrated Circuit. All vision system elements including firmware can be integrated onto one ASIC. Aspect Ratio - The ratio between the height and width of a sensor or display. It is found by dividing the vertical number of pixels (height) by the horizontal number of pixels (width) leaving it in fractional format. Auxiliary Port - RS-232 connections to an auxiliary terminal or device for remote viewing. the transfer of data to and from the host, and under certain conditions a configuration port. Blooming - The situation where too many photons are being produced to be received by a pixel. The pixel overflows and causes the photons to go to adjacent pixels. Blooming is similar to overexposure in film photography, except that in digital imaging, the result is a number of vertical and/or horizontal streaks appearing from the light source in the picture. Baud Rate - The number of discrete signal events per second. Bits per second. Capture - The act of acquiring and storing video images in an Imager or computer. Also, the image captured. Check Digit - A Modulus 43 or Modulus 10 digit that is added to the bar code message for additional data integrity. CMOS - Complementary Metal Oxide Semiconductor. Like CCDs, CMOS Imagers include an array of photo-sensitive diodes, one diode within each pixel. Unlike CCDs, however, each pixel in a CMOS Imager has its own individual amplifier integrated inside. Connector - Physical device (plug or socket) on a device or cable to provide in/out connectivity for various circuits and pins. A-26
FIS-6300 ESD Imager User’s Manual