For the Wenglor FIS-6300

Page 311

Output Format

Length Definition:

Specifies the length of the decoded symbol allowed to occupy this location in multi-symbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.

Serial Cmd:

<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>

Default:

0

Options:

0 to 64

Wildcard Definition:

This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.

Serial Cmd:

<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>

Default:

“ * “ = 2A (hex)

Options:

Any ASCII input in the form of a pair of hex characters. Example: 2A = * 00 = disabled

See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.

Placeholder Definition:

The placeholder character requires a character to be present, but does not compare the data value.

Serial Cmd:

<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>

Default:

“ ? ” = 3F (hex)

Options:

Any ASCII input in the form of a pair of hex characters. Example: 3F = ? 00 = disabled

See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values. FIS-6300 ESD Imager User’s Manual

14-11

Page 312

Output Filter Configuration

Data Definition:

This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”.

Serial Cmd:

<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>

Default:

00 (NUL)

Options:

Any ASCII input in the form of a pair of hex characters. Maximum length: 63 bytes defined. Examples: 41422A = AB* Data [0] = NUL represents string matching disabled.

See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.

Database Index Definition:

The index of the database entry that decodes a given symbol must equal this setting for filtering to occur. A setting of 0 allows any database index for this filter entry.

Serial Cmd:

<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>

Default:

0 (any index)

Options:

0 to 10

14-12

FIS-6300 ESD Imager User’s Manual

Page 313

Output Format

Ordered Output Filter Definition:

Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 1, then only filter index # 1 will be applied. If the number of filters is 2, then only filter index # 1 and filter index # 2 will be applied, etc.

Serial Cmd:

<K745,number of filters>

Default:

0

Options:

0 to 10

FIS-6300 ESD Imager User’s Manual

14-13

Page 314

Ordered Output Filter

14-14

FIS-6300 ESD Imager User’s Manual

Page 315

Appendices Contents Appendix A General Specifications .............................................................................................. A-2 Appendix B Electrical Specifications ............................................................................................ A-5 Appendix C Serial Configuration Commands............................................................................... A-6 Appendix D Communications Protocol....................................................................................... A-12 Appendix E ASCII Table............................................................................................................. A-21 Appendix F Interface Standards................................................................................................. A-22 Appendix G wenglor Sensor....................................................................................................... A-23 Appendix H Operational Tips ..................................................................................................... A-24 Appendix I Glossary of Terms .................................................................................................... A-25

FIS-6300 ESD Imager User’s Manual

A-1

Page 316

General Specifications

Appendix A, General Specifications Mechanical Height: 1" (25.4 mm) Width: 1.8" (45.7 mm) Depth: 2.10" (53.3 mm) Weight: 2 oz. (57 g)

Environmental Enclosure: IP54 Operating Tempurature: 0° to 40°C (32° to 104°F) Storage Tempurature: -50° to 75° C (-58 to 167°F) Humidity: up to 90% (non-condensing)

2X 2-56 .20" depth

1" (25.4 mm)

.20" (5.1 mm) .15" (3.9 mm)

1.5" (38 mm) 1.8" (45.7 mm)

Light Source Type: High output LEDs.

Light Collection Options Progressive scan, square pixel. Software adjustable shutter speed, electronic shutter. SXGA: 1280 by 1024 pixels.

Connector Type: 3 ft. cable terminated with High Density 15-pin D-Sub socket connector.

2.10" (53.3 mm)

2X M3X0.5 5 mm depth

Indicators LEDS: Read Performance, Power, Read Status. Green Flash: Good read. Blue Target Pattern: Symbol locator. Beeper: Good read, match/mismatch, noread, serial command confirmation, on/off.

.51" (12.9 mm)

.26" (6.6 mm)

Discrete I/O

1.25" (31.8 mm)

FIS-6300 ESD Imager Dimensions

Trigger Input: 5 to 28VDC (0.16 mA) New Master: 5 to 28VDC (0.16 mA) Outputs (1, 2, 3): 5V TTL compatible, can sink 10 mA and source 10mA Optional I/O: Optoisolated (with IC-332 accessory)

Communication Protocols Standard Interface: RS-232, RS-422

Symbology Types 2D Symbologies: Data Matrix (ECC 0-200), QR Code Stacked Symbologies: PDF417, MicroPDF417, RSS (Composite & Stacked) Linear Symbologies: Code 39, Code 128, BC412, Interleaved 2 of 5, Pharmacode, UPC/EAN, Codabar, Code 93

Read Parameters Pitch: ±30° Skew: ±30° Tilt: 360° Decode Rate: Up to 10 decodes per second. Focal Range: 2 to 6” (50.8 to 152.4 mm) (autofocus)

A-2

FIS-6300 ESD Imager User’s Manual

Page 317

Appendices Read Ranges Ultra High Density

High Density

51

Standard Density

Narrow-bar-width 1D

2D

Field of View

Read Range

(maximum)

(with autofocus)

Ultra High Density .0033" (0.08 mm)

.005" (.13 mm)

2.2" (56 mm)

2.0 to 4.4" (51 mm to 112 mm)

.0075" (0.19 mm)

.010" (.25 mm)

3.6" (91 mm)

1.9 to 6.7" (48 mm to 170 mm)

.015" (0.38 mm)

.020" (.51 mm)

4.0" (102 mm)

1.9 to 7.7" (48 mm to 196 mm)

High Density .005" (0.13 mm)

.0075" (.19 mm)

3.1" (79 mm)

.0075" (0.19 mm)

.010" (.25 mm)

4.2" (107 mm)

1.5 to 6.0" (38 mm to 152 mm) 1.2 to 8.0" (30 mm to 203 mm)

.015" (0.38 mm)

.020" (.51 mm)

5.6" (142 mm)

0.9 to 10.5" (23 mm to 267 mm)

Standard Density .005" (0.13 mm)

.0075" (.19 mm)

3.2" (81 mm)

1.8 to .5" (46 mm to 89 mm)

.0075" (0.19 mm)

.010" (.25 mm)

4.2" (107 mm)

1.6 to 5.0" (41 mm to 127 mm)

.010" (0.25 mm)

.015" (.38 mm)

6.8" (173 mm)

1.4 to 7.5" (36 mm to 191 mm)

.020" (0.51 mm)

.030" (.76 mm)

9.5" (241 mm)

1.0 to 11.0" (25 mm to 279 mm)

FIS-6300 ESD Imager User’s Manual

A-3

Page 318

General Specifications CE Mark General Immunity for Light Industry: EN 55024: 1998 ITE Immunity Standard Radiated and Conducted Emissions of ITE Equipment: EN 55022:98 ITE Disturbances

Safety Certifications FCC, UL/cUL, CE, CB

ISO Certification ISO 9001:2000 Certification No. 281960 QM © 2005 wenglor sensoric gmbh All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes.

A-4

FIS-6300 ESD Imager User’s Manual

Page 319

Appendices

Appendix B, Electrical Specifications Power: 5 VDC +/– 5 %, 200 mV p-p max. ripple, 440 mA @ 5 VDC (typ.) Optional I/O: Optoisolated (with IC-332 accessory)

Host Connector / Pin Assignments High Density 15 Pin D-sub Socket Connector Pin

Host RS-232

Host/Aux RS-232

1 2

TxD

3

RxD

4

In/Out

TxD

TxD(–)

Out

RxD

RxD(–)

In

In

Power/Signal Ground

5 6

Host RS-422/485

Power +5 VDC

NC RTS

Aux TxD

TxD(+)

Out

7

Output 1 TTL a

8

Default configuration b

In

9

Trigger

In

10

CTS

Aux RxD

Out

RxD (+)

In

11

Output 3 TTL a

Out

12

New Master (NPN)

In

13

Chassis ground c

14

Output 2 TTL a

15

NC

Out a. Can sink 10 mA and source 10 mA. b. The default is activated by connecting pin 8 to ground pin 4. c. Chassis ground: Used to connect chassis body to earthground only. Not to be used as power or signal return.

FIS-6300 ESD Imager User’s Manual

A-5

Page 320

Serial Configuration Commands

Appendix C, Serial Configuration Commands Communications Host Port Connections Auxiliary Port Connections RS-422 Status Host Port Protocol Preamble Postamble Response Timeout LRC Auxiliary Port System Data Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Calibration Calibration Options Autocalibrate Read Cycle Trigger Mode/Duration Serial Trigger Character External Trigger State End of Read Cycle Minimum Good Reads Multisymbol Start Trigger Character Stop Trigger Character Capture Mode Capture Timing Image Storage IP Timeout Symbologies Narrow Margins/Symbology ID Background Color Composite Code 39

A-6

<K100,baud rate,parity,stop bits,data bits> <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> <K102,status> <K140,protocol,address> <K141,status,preamble characters> <K142,status,postamble characters> <K143,response timeout> <K145,status> <K146,aux> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height> <@CAL> <K200,trigger mode,trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,end of read cycle,read cycle timeout> <K221,minimum good reads> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K241,capture mode,number of captures,rapid capture mode, pre-processing> <K242,time before first capture,time between first and second captures,,,,,,,,time between seventh and eighth captures> <K244,image storage type,image store mode> <K245,image processing timeout> <K450,narrow margin status,symbology identifier status> <K451,background color> <K453,symbology status,separator status,separator> <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>

FIS-6300 ESD Imager User’s Manual