Page 311
Output Format
Length Definition:
Specifies the length of the decoded symbol allowed to occupy this location in multi-symbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
0
Options:
0 to 64
Wildcard Definition:
This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
“ * “ = 2A (hex)
Options:
Any ASCII input in the form of a pair of hex characters. Example: 2A = * 00 = disabled
See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
Placeholder Definition:
The placeholder character requires a character to be present, but does not compare the data value.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
“ ? ” = 3F (hex)
Options:
Any ASCII input in the form of a pair of hex characters. Example: 3F = ? 00 = disabled
See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values. FIS-6300 ESD Imager User’s Manual
14-11
Page 312
Output Filter Configuration
Data Definition:
This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
00 (NUL)
Options:
Any ASCII input in the form of a pair of hex characters. Maximum length: 63 bytes defined. Examples: 41422A = AB* Data [0] = NUL represents string matching disabled.
See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
Database Index Definition:
The index of the database entry that decodes a given symbol must equal this setting for filtering to occur. A setting of 0 allows any database index for this filter entry.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Default:
0 (any index)
Options:
0 to 10
14-12
FIS-6300 ESD Imager User’s Manual
Page 313
Output Format
Ordered Output Filter Definition:
Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 1, then only filter index # 1 will be applied. If the number of filters is 2, then only filter index # 1 and filter index # 2 will be applied, etc.
Serial Cmd:
<K745,number of filters>
Default:
0
Options:
0 to 10
FIS-6300 ESD Imager User’s Manual
14-13
Page 314
Ordered Output Filter
14-14
FIS-6300 ESD Imager User’s Manual
Page 315
Appendices Contents Appendix A General Specifications .............................................................................................. A-2 Appendix B Electrical Specifications ............................................................................................ A-5 Appendix C Serial Configuration Commands............................................................................... A-6 Appendix D Communications Protocol....................................................................................... A-12 Appendix E ASCII Table............................................................................................................. A-21 Appendix F Interface Standards................................................................................................. A-22 Appendix G wenglor Sensor....................................................................................................... A-23 Appendix H Operational Tips ..................................................................................................... A-24 Appendix I Glossary of Terms .................................................................................................... A-25
FIS-6300 ESD Imager User’s Manual
A-1
Page 316
General Specifications
Appendix A, General Specifications Mechanical Height: 1" (25.4 mm) Width: 1.8" (45.7 mm) Depth: 2.10" (53.3 mm) Weight: 2 oz. (57 g)
Environmental Enclosure: IP54 Operating Tempurature: 0° to 40°C (32° to 104°F) Storage Tempurature: -50° to 75° C (-58 to 167°F) Humidity: up to 90% (non-condensing)
2X 2-56 .20" depth
1" (25.4 mm)
.20" (5.1 mm) .15" (3.9 mm)
1.5" (38 mm) 1.8" (45.7 mm)
Light Source Type: High output LEDs.
Light Collection Options Progressive scan, square pixel. Software adjustable shutter speed, electronic shutter. SXGA: 1280 by 1024 pixels.
Connector Type: 3 ft. cable terminated with High Density 15-pin D-Sub socket connector.
2.10" (53.3 mm)
2X M3X0.5 5 mm depth
Indicators LEDS: Read Performance, Power, Read Status. Green Flash: Good read. Blue Target Pattern: Symbol locator. Beeper: Good read, match/mismatch, noread, serial command confirmation, on/off.
.51" (12.9 mm)
.26" (6.6 mm)
Discrete I/O
1.25" (31.8 mm)
FIS-6300 ESD Imager Dimensions
Trigger Input: 5 to 28VDC (0.16 mA) New Master: 5 to 28VDC (0.16 mA) Outputs (1, 2, 3): 5V TTL compatible, can sink 10 mA and source 10mA Optional I/O: Optoisolated (with IC-332 accessory)
Communication Protocols Standard Interface: RS-232, RS-422
Symbology Types 2D Symbologies: Data Matrix (ECC 0-200), QR Code Stacked Symbologies: PDF417, MicroPDF417, RSS (Composite & Stacked) Linear Symbologies: Code 39, Code 128, BC412, Interleaved 2 of 5, Pharmacode, UPC/EAN, Codabar, Code 93
Read Parameters Pitch: ±30° Skew: ±30° Tilt: 360° Decode Rate: Up to 10 decodes per second. Focal Range: 2 to 6” (50.8 to 152.4 mm) (autofocus)
A-2
FIS-6300 ESD Imager User’s Manual
Page 317
Appendices Read Ranges Ultra High Density
High Density
51
Standard Density
Narrow-bar-width 1D
2D
Field of View
Read Range
(maximum)
(with autofocus)
Ultra High Density .0033" (0.08 mm)
.005" (.13 mm)
2.2" (56 mm)
2.0 to 4.4" (51 mm to 112 mm)
.0075" (0.19 mm)
.010" (.25 mm)
3.6" (91 mm)
1.9 to 6.7" (48 mm to 170 mm)
.015" (0.38 mm)
.020" (.51 mm)
4.0" (102 mm)
1.9 to 7.7" (48 mm to 196 mm)
High Density .005" (0.13 mm)
.0075" (.19 mm)
3.1" (79 mm)
.0075" (0.19 mm)
.010" (.25 mm)
4.2" (107 mm)
1.5 to 6.0" (38 mm to 152 mm) 1.2 to 8.0" (30 mm to 203 mm)
.015" (0.38 mm)
.020" (.51 mm)
5.6" (142 mm)
0.9 to 10.5" (23 mm to 267 mm)
Standard Density .005" (0.13 mm)
.0075" (.19 mm)
3.2" (81 mm)
1.8 to .5" (46 mm to 89 mm)
.0075" (0.19 mm)
.010" (.25 mm)
4.2" (107 mm)
1.6 to 5.0" (41 mm to 127 mm)
.010" (0.25 mm)
.015" (.38 mm)
6.8" (173 mm)
1.4 to 7.5" (36 mm to 191 mm)
.020" (0.51 mm)
.030" (.76 mm)
9.5" (241 mm)
1.0 to 11.0" (25 mm to 279 mm)
FIS-6300 ESD Imager User’s Manual
A-3
Page 318
General Specifications CE Mark General Immunity for Light Industry: EN 55024: 1998 ITE Immunity Standard Radiated and Conducted Emissions of ITE Equipment: EN 55022:98 ITE Disturbances
Safety Certifications FCC, UL/cUL, CE, CB
ISO Certification ISO 9001:2000 Certification No. 281960 QM © 2005 wenglor sensoric gmbh All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes.
A-4
FIS-6300 ESD Imager User’s Manual
Page 319
Appendices
Appendix B, Electrical Specifications Power: 5 VDC +/– 5 %, 200 mV p-p max. ripple, 440 mA @ 5 VDC (typ.) Optional I/O: Optoisolated (with IC-332 accessory)
Host Connector / Pin Assignments High Density 15 Pin D-sub Socket Connector Pin
Host RS-232
Host/Aux RS-232
1 2
TxD
3
RxD
4
In/Out
TxD
TxD(–)
Out
RxD
RxD(–)
In
In
Power/Signal Ground
5 6
Host RS-422/485
Power +5 VDC
NC RTS
Aux TxD
TxD(+)
Out
7
Output 1 TTL a
8
Default configuration b
In
9
Trigger
In
10
CTS
Aux RxD
Out
RxD (+)
In
11
Output 3 TTL a
Out
12
New Master (NPN)
In
13
Chassis ground c
14
Output 2 TTL a
15
NC
Out a. Can sink 10 mA and source 10 mA. b. The default is activated by connecting pin 8 to ground pin 4. c. Chassis ground: Used to connect chassis body to earthground only. Not to be used as power or signal return.
FIS-6300 ESD Imager User’s Manual
A-5
Page 320
Serial Configuration Commands
Appendix C, Serial Configuration Commands Communications Host Port Connections Auxiliary Port Connections RS-422 Status Host Port Protocol Preamble Postamble Response Timeout LRC Auxiliary Port System Data Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Calibration Calibration Options Autocalibrate Read Cycle Trigger Mode/Duration Serial Trigger Character External Trigger State End of Read Cycle Minimum Good Reads Multisymbol Start Trigger Character Stop Trigger Character Capture Mode Capture Timing Image Storage IP Timeout Symbologies Narrow Margins/Symbology ID Background Color Composite Code 39
A-6
<K100,baud rate,parity,stop bits,data bits> <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> <K102,status> <K140,protocol,address> <K141,status,preamble characters> <K142,status,postamble characters> <K143,response timeout> <K145,status> <K146,aux> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K529,gain,shutter speed,focus position,symbol type,WOI framing,WOI margin,line scan height> <@CAL> <K200,trigger mode,trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,end of read cycle,read cycle timeout> <K221,minimum good reads> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K241,capture mode,number of captures,rapid capture mode, pre-processing> <K242,time before first capture,time between first and second captures,,,,,,,,time between seventh and eighth captures> <K244,image storage type,image store mode> <K245,image processing timeout> <K450,narrow margin status,symbology identifier status> <K451,background color> <K453,symbology status,separator status,separator> <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
FIS-6300 ESD Imager User’s Manual