Page 151
8 Symbol Quality Contents Symbol Quality by ESP................................................................................................................. 8-2 Symbol Quality Serial Commands ................................................................................................ 8-3 Overview of Symbol Quality.......................................................................................................... 8-4 Symbol Quality Separator / Data Matrix Output Mode.................................................................. 8-5 ISO/IEC 16022 Symbol Quality Output......................................................................................... 8-7 ISO/IEC 16022 Symbol Quality Output by ESP............................................................................ 8-9 wenglor Symbol Quality Output .................................................................................................. 8-10 wenglor Symbol Quality Output by ESP ..................................................................................... 8-13
This section describes parameters that, when enabled, will output detailed symbol quality evaluations.
FIS-6300 ESD Imager User’s Manual
8-1
Page 152
Symbol Quality by ESP
Symbol Quality by ESP
To open nested options, single-click the +. Click this button to bring up the Symbol Quality menu.
To change a setting, double-click the setting and use your cursor to scroll through the options.
8-2
FIS-6300 ESD Imager User’s Manual
Page 153
Symbol Quality
Symbol Quality Serial Commands Symbol Quality Separator/ Data <K708,symbol quality separator,data matrix output mode> Matrix Output Mode ISO/IEC 16022 Symbol Quality <K709,symbol contrast,print growth,axial non-uniformity,UEC> Output <K710,percent cell damage,total read time,capture wenglor Symbol Quality Output time,locate time,decode time,pixels per element,EC level,matrix size,quiet zone> Static Validation Report <VAL>
FIS-6300 ESD Imager User’s Manual
8-3
Page 154
Overview of Symbol Quality
Overview of Symbol Quality Information about symbol quality and timing can be appended to symbol data output by enabling specific parameters in ESP or by serial command. The order in which these values will be appended corresponds directly to the order in which they appear in this section and in the ESP Symbol Quality menu. For example, if you enable the outputs shown, they will be returned in the order shown here: Total Read Time (Global)
Symbol Contrast (ISO/IEC 16022)
Capture Time (wenglor Grading)
Locate Time Decode Time (wenglor (wenglor Grading) Grading)
Pixels/Element (wenglor Grading)
Both elements enabled
Symbol data output
0123456789abcdefghijklmnopqrstuv 256 A 30 210 3 13 17 dark pixels light pixels
Symbol Quality parameters are separated into ISO/IEC 16022 Symbol Quality Output and wenglor Symbol Quality Output. In addition, there are two parameters, Total Read Time and Symbol Quality Separator, that are common to both.
8-4
FIS-6300 ESD Imager User’s Manual
Page 155
Symbol Quality
Symbol Quality Separator / Data Matrix Output Mode Symbol Quality Separator applies to both Symbol Quality groups: ISO/IEC 16022 Symbol Quality Output and wenglor Symbol Quality Output.
Symbol Quality Separator Definition: Serial Cmd: Default: Options:
Inserts a separator between each enabled field of the symbol quality output. <K708,symbol quality separator,output mode> <SP> (space character) Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K708h,3C> For >: <K708h,3E> For , : <K708h,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
Symbol Quality Separator by ESP
When you double-click on the default separator SP, the Symbol Quality Separator Calculator appears. Use the calculator keypad for one-click separator configuration.
FIS-6300 ESD Imager User’s Manual
8-5
Page 156
Symbol Quality Separator / Data Matrix Output Mode
Data Matrix Output Mode Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters. Definition: Serial Cmd: Default: Options:
Output Mode specifies how the four output parameters, if enabled, are formatted. <K708,symbol quality separator,output mode> Grade 0 = Grade 1 = Value
Grade If in Grade Mode, a grade (A,B,C,D) is appended to the symbol data.
Value If in Value Mode, the calculated value for the given parameter is appended to the symbol data.
8-6
FIS-6300 ESD Imager User’s Manual
Page 157
Symbol Quality
ISO/IEC 16022 Symbol Quality Output Symbol Quality Parameters for Data Matrix symbols specified by ISO/IEC 16022.
Symbol Contrast Usage: Definition:
Serial Cmd: Default: Options:
Lets the user know if contrast settings are less than acceptable. All the pixels that fall within the area of the test symbol, including its required zone, will be sorted by their reflectance values to select the darkest 10% and the lightest 10% of the pixels. The arithmetic mean of the darkest and the lightest pixels is calculated and the difference of the two means is the Symbol Contrast. (ANSI) Symbol Contrast grading is defined this way: A (4.0) if SC > 70% B (3.0) if SC > 55% C (2.0) if SC > 40% D (1.0) if SC > 20% F (0.0) if SC > 20% If enabled, the symbol contrast is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
Print Growth Definition:
Serial Cmd: Default: Options:
The extent to which dark or light markings appropriately fill or exceed their module boundaries. These values are determined by counting pixels in the clock pattern of the binary digitized image, then comparing it to a nominal value and minimum and maximum values. The print growth grade is defined in this way: A (4.0) if -.050 < PG < 0.50 B (3.0) if -.070 < PG < 0.70 C (2.0) if -.085 < PG < 0.85 D (1.0) if -.10 < PG < 1.00 F (0.0) if PG < -1.00 or PG > 1.00 If enabled, the print growth is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
8-7
Page 158
ISO/IEC 16022 Symbol Quality Output
Axial Non-Uniformity (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
Axial non-uniformity is a measure of how much the sampling point spacing differs from one axis to another, namely AN = abs (XAVG - YAVG) / ((XAVG + YAVG)/2) where abs () yields the absolute value. If a symbology has more than two major axes, then AN is computed for those two average spacings which differ the most. (ANSI) axial non-uniformity grading is defined this way: A (4.0) if AN < .06 B (2.0) if AN < .08 C (2.0) if AN < .10 D (1.0) if AN < .12 F (0.0) if AN > .12 If enabled, the axial non-uniformity is appended to the symbol data according the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
Unused Error Correction (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
8-8
The correction capacity of Reed-Solomon decoding is expressed in the equation: e + 2d < d - p, where e is the number of erasures, d is the number of error correction code words, and p is the number of code words reserved for error detection. A (4.0) if UEC > .62 B (3.0) if UEC > .50 C (2.0) if UEC > .37 D (1.0) if UEC > .25 F (0.0) if UEC < .25 If enabled, the UEC is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
Page 159
Symbol Quality
ISO/IEC 16022 Symbol Quality Output by ESP ESP’s Symbol Quality interface allows you to evaluate Data Matrix symbols for compliance with ISO/IEC 16022 requirements. First, determine which ISO/IEC 16022 Parameters you need to evaluate, using the Symbol Quality tree control.
Once you’ve set these Data Matrix evaluation parameters, go to the Preferences tab and set your Data Matrix Grading Report output preferences.
After your output preferences are set, click the Data Matrix Grading button.
There will be a wait of a few seconds, and then the evaluation results will appear at the lower right of the Symbol Quality view, in a format similar to the one shown below.
If you want to view the results in a report format, click the Generate Report button. The report will be output in the format you chose in the Preferences dialog (Default Report Type).
FIS-6300 ESD Imager User’s Manual
8-9
Page 160
wenglor Symbol Quality Output wenglor Symbol Quality Output Percent Cell Damage (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
Number of cells (also called elements) damaged per total number of cells x 100. The ideal reading is 0 (zero). If enabled, it is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,EC level,matrix size,quiet zone> Disabled 0 = Disabled 1 = Enabled
Total Read Time Definition: Serial Cmd: Default: Options:
The time that transpires between the image capture and the output of the decoded data, including locate time. If enabled, it is appended to the symbol data. <K710,percent cell damage,total read timea,capture time,locate time,decode time,pixels per element,EC level,matrix size,quiet zone> Disabled 0 = Disabled 1 = Enabled a. Total Read Time applies globally to all three Symbol Quality standards.
Capture Time Definition:
Serial Cmd: Default: Options:
Capture time (in milliseconds) is a fixed “overhead” that includes the time of capture and transfer of the image. If enabled, it is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,EC level,matrix size,quiet zone> Disabled 0 = Disabled 1 = Enabled
Locate Time Definition: Serial Cmd: Default: Options: 8-10
The time in milliseconds from the start of image processing until the symbol has been located and is ready to be decoded. If enabled, it is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,EC level,matrix size,quiet zone> Disabled 0 = Disabled 1 = Enabled FIS-6300 ESD Imager User’s Manual