Page 328
Appendices Options:
0 = Disabled
1 = Enabled
Check Character Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Check Character Output Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length #1 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 128
Symbol Length #2 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 128
Guard Bar Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Range Mode Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled
UPC/EAN Serial Cmd:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Default: 3 = Both Standard and Edge-to-Edge Options: 0 = Disabled FIS-0870 Industrial Raster Scanner User’s Manual A-41
Page 329
1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge EAN Status Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 1 = Enabled 0 = Disabled 1 = Enabled
Supplementals Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required
Separator Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
Separator Character (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any 7-bit ASCII character
Supplemental Type (UPC/EAN) Serial Cmd: Default: Options:
A-42
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Both 0 = Both 1 = 2 characters only 2 = 5 characters only
FIS-0870 Industrial Raster Scanner User’s Manual
Page 330
Appendices Format UPC-E as UPC-A (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
Code 128/EAN 128 Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
Fixed Symbol Length Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding, separation factor> 10 1 to 128
EAN 128 Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Required
FIS-0870 Industrial Raster Scanner User’s Manual
A-43
Page 331
Output Format (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Standard 0 = Standard 1 = Application
Application Record Separator Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Separator Character (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> , (comma) Any 7-bit ASCII character
Application Record Brackets (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Padding (Code 128/EAN 128) Serial Cmd:
Default: Options:
A-44
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
FIS-0870 Industrial Raster Scanner User’s Manual
Page 332
Appendices Separation Factor Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Normal 0 = Normal 1 = High 2 = Highest
Code 93 Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
Fixed Symbol Length Status (Code 93) Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length (Code 93) Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 10 1 to 128
PDF417 Serial Cmd: Default: Options:
<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Raster Sweep Count Serial Cmd: Default: Options:
<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 65535 1 to 65535
FIS-0870 Industrial Raster Scanner User’s Manual
A-45
Page 333
Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:
<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (PDF417) Serial Cmd: Default: Options:
<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 10 1 to 2710
Decode at End of Read Cycle (PDF417) Serial Cmd: Default: Options:
<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Pharmacode Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 10 1 to 16
Minimum Bars (Pharmacode) Serial Cmd: Default: Options:
A-46
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 4 1 to 16
FIS-0870 Industrial Raster Scanner User’s Manual
Page 334
Appendices Bar Width Status (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Direction (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Forward 0 = Forward 1 = Reverse
Fixed Threshold Value (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 400 1 to 65535
FIS-0870 Industrial Raster Scanner User’s Manual
A-47
Page 335
GS1 DataBar (RSS) DataBar Omnidirectional (RSS-14) Serial Cmd: Default: Options:
<K482,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Limited (RSS Limited) Serial Cmd: Default: Options:
<K483,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Expanded (RSS Expanded) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (DataBar Expanded) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (DataBar Expanded) Serial Cmd: Default: Options:
A-48
<K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74
FIS-0870 Industrial Raster Scanner User’s Manual
Page 336
Appendices
MicroPDF417 Serial Cmd: Default: Options:
<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Raster Sweep Count (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 65535 1 to 65535
Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 10 1 to 366
FIS-0870 Industrial Raster Scanner User’s Manual
A-49
Page 337
Symbol Reconstruction Symbol Reconstruction Redundancy Serial Cmd: Default: Options:
<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Disabled 0 = Disabled 1 = Low 2 = Medium 3 = High
Symbol Reconstruction Effort Serial Cmd: Default: Options:
A-50
<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Minimum 0 = Minimum 1 = Moderate 2 = Maximum
FIS-0870 Industrial Raster Scanner User’s Manual