Page 328

Appendices Options:

0 = Disabled

1 = Enabled

Check Character Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Check Character Output Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Length #1 (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 128

Symbol Length #2 (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 128

Guard Bar Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Range Mode Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled

UPC/EAN Serial Cmd:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Default: 3 = Both Standard and Edge-to-Edge Options: 0 = Disabled FIS-0870 Industrial Raster Scanner User’s Manual A-41

Page 329

1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge EAN Status Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 1 = Enabled 0 = Disabled 1 = Enabled

Supplementals Status (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required

Separator Status (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled

Separator Character (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any 7-bit ASCII character

Supplemental Type (UPC/EAN) Serial Cmd: Default: Options:

A-42

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Both 0 = Both 1 = 2 characters only 2 = 5 characters only

FIS-0870 Industrial Raster Scanner User’s Manual

Page 330

Appendices Format UPC-E as UPC-A (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled

Code 128/EAN 128 Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge

Fixed Symbol Length Status (Code 128/EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (Code 128/EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding, separation factor> 10 1 to 128

EAN 128 Status (Code 128/EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Required

FIS-0870 Industrial Raster Scanner User’s Manual

A-43

Page 331

Output Format (Code 128/EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Standard 0 = Standard 1 = Application

Application Record Separator Status (Code 128/EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Application Record Separator Character (Code 128/EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> , (comma) Any 7-bit ASCII character

Application Record Brackets (Code 128/EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Application Record Padding (Code 128/EAN 128) Serial Cmd:

Default: Options:

A-44

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

FIS-0870 Industrial Raster Scanner User’s Manual

Page 332

Appendices Separation Factor Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Normal 0 = Normal 1 = High 2 = Highest

Code 93 Serial Cmd: Default: Options:

<K475,status,fixed symbol length status,symbol length> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge

Fixed Symbol Length Status (Code 93) Serial Cmd: Default: Options:

<K475,status,fixed symbol length status,symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Length (Code 93) Serial Cmd: Default: Options:

<K475,status,fixed symbol length status,symbol length> 10 1 to 128

PDF417 Serial Cmd: Default: Options:

<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled

Raster Sweep Count Serial Cmd: Default: Options:

<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 65535 1 to 65535

FIS-0870 Industrial Raster Scanner User’s Manual

A-45

Page 333

Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:

<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (PDF417) Serial Cmd: Default: Options:

<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 10 1 to 2710

Decode at End of Read Cycle (PDF417) Serial Cmd: Default: Options:

<K476,status,raster sweep count,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled

Pharmacode Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 10 1 to 16

Minimum Bars (Pharmacode) Serial Cmd: Default: Options:

A-46

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 4 1 to 16

FIS-0870 Industrial Raster Scanner User’s Manual

Page 334

Appendices Bar Width Status (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold

Direction (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Forward 0 = Forward 1 = Reverse

Fixed Threshold Value (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 400 1 to 65535

FIS-0870 Industrial Raster Scanner User’s Manual

A-47

Page 335

GS1 DataBar (RSS) DataBar Omnidirectional (RSS-14) Serial Cmd: Default: Options:

<K482,status> 0 = Disabled 0 = Disabled

1 = Enabled

DataBar Limited (RSS Limited) Serial Cmd: Default: Options:

<K483,status> 0 = Disabled 0 = Disabled

1 = Enabled

DataBar Expanded (RSS Expanded) Serial Cmd: Default: Options:

<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (DataBar Expanded) Serial Cmd: Default: Options:

<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (DataBar Expanded) Serial Cmd: Default: Options:

A-48

<K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74

FIS-0870 Industrial Raster Scanner User’s Manual

Page 336

Appendices

MicroPDF417 Serial Cmd: Default: Options:

<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Raster Sweep Count (MicroPDF417) Serial Cmd: Default: Options:

<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 65535 1 to 65535

Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:

<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (MicroPDF417) Serial Cmd: Default: Options:

<K485,status,raster sweep count,fixed symbol length status,fixed symbol length> 10 1 to 366

FIS-0870 Industrial Raster Scanner User’s Manual

A-49

Page 337

Symbol Reconstruction Symbol Reconstruction Redundancy Serial Cmd: Default: Options:

<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Disabled 0 = Disabled 1 = Low 2 = Medium 3 = High

Symbol Reconstruction Effort Serial Cmd: Default: Options:

A-50

<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Minimum 0 = Minimum 1 = Moderate 2 = Maximum

FIS-0870 Industrial Raster Scanner User’s Manual