Appendices Read Cycle On/Off Serial Cmd: Default: Options:
<K506,status,top offset,bottom offset,sweep rate,read cycle on/off> 0 = Disabled 0 = Disabled 1 = Enabled
Scan Width Enhance Serial Cmd: Default: Options:
<K511,status> 0 = Disabled 0 = Disabled
1 = Enabled
AGC Tracking Serial Cmd: Default: Options:
<K520,tracking value> 40 (FIS-0870 model-dependent – see wenglor Product Pricing Catalog) 5 to 127
Laser Setup Laser On/Off Status Serial Cmd: Default: Options:
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power> 0 = Disabled 0 = Disabled 1 = Enabled
Laser Framing Status Serial Cmd: Default: Options:
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power> 0 = Disabled 0 = Disabled 1 = Enabled
Laser On Position Serial Cmd: Default: Options:
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power> 10 10 to 90
Laser Off Position Serial Cmd: Default: Options:
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power> 95 15 to 95
FIS-0870 Industrial Raster Scanner User’s Manual
A-31
Page 319
Laser Power Serial Cmd: Default: Options:
A-32
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power> 1 = Medium 0 = Low 1 = Medium 2 = High
FIS-0870 Industrial Raster Scanner User’s Manual
Page 320
Appendices
Configuration Database Number of Active Indexes Configuration Database Switch Timing
<K252,number of active indexes,number of database cycles> <K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status,laser on position,laser off position,laser power, background color> <K254,switch mode,frame count/time>
Number of Active Indexes Number of Active Indexes Serial Cmd: Default: Options:
<K252,number of active indexes,number of database cycles> 0 (Disabled) 0 to 10
Number of Database Cycles Serial Cmd: Default: Options:
<K252,number of active indexes,number of database cycles> 0 (Disabled) 0 to 255
Configuration Database Index Serial Cmd: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 1 to 10 (database index number)
Gain Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power,background color> 40 0 to 255
AGC Mode Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed, framing status,laser on position,laser off position,laser power,background color> 2 = Continuous 0 = Disabled 1 = Leading Edge 2 = Continuous
FIS-0870 Industrial Raster Scanner User’s Manual
A-33
Page 321
Tracking Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 40 5 to 127
Raster Top Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 88 0 to 255
Raster Bottom Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 167 0 to 255
Raster Speed Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 10 0 to 80
Framing Status Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power,background color> 0 = Disabled 0 = Disabled 1 = Enabled
Laser On Position Serial Cmd: Default: Options:
A-34
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 10 10 to 90
FIS-0870 Industrial Raster Scanner User’s Manual
Page 322
Appendices Laser Off Position Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 95 15 to 95
Laser Power Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,,framing status, laser on position,laser off position,laser power,background color> 1 = Medium 0 = Low 1 = Medium 2 = High
Background Color Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power,background color> 0 = White 0 = White 1 = Black
Switch Timing Switch Mode Serial Cmd: Default: Options:
<K254,switch mode,frame count/time> 0 = Time 0 = Time 1 = Number of raster sweeps
Frame Count/Time Serial Cmd: Default: Options:
<K254,switch mode,frame count/time> 10 (100 ms) 1 to 65535 (in 10 ms increments)
FIS-0870 Industrial Raster Scanner User’s Manual
A-35
Page 323
Symbologies Quiet Zone Background Color Symbol Ratios Composite AIAG Depth of Field Enhance Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode DataBar Omnidirectional (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded) MicroPDF417 Symbol Reconstruction
<K450,quiet zone status> <K451,background color> <K452,Code 39,Codabar,Interleaved 2 of 5> <K453,symbology status,separator status,separator> <K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4, ID5a,ID5b,ID5c,status5, ID6,status6,ID7,status7,ID8, status8, ID9,status9,ID10,status10,ID11,status11,ID12,status12> <K456,DOF Enhance mode> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar,range mode status> <K473,mode,EAN status,supplementals status,separator status, separator character,supplementals type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN status,output format,application record separator status, application record separator character,application record brackets, application record padding,separation factor> <K475,mode,fixed symbol length status,symbol length> <K476,status,raster sweep count,fixed symbol length status, fixed symbol length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,raster sweep count,fixed symbol length status, fixed symbol length> <K496,symbol reconstruction redundancy,symbol reconstruction effort>
Quiet Zone Serial Cmd: Default: Options:
A-36
<K450,quiet zone status> 3 = Narrow, Enhanced 0 = Standard 1 = Narrow 2 = Standard, Enhanced 3 = Narrow, Enhanced
FIS-0870 Industrial Raster Scanner User’s Manual
Page 324
Appendices
Background Color Serial Cmd: Default: Options:
<K451,background color> 0 = White 1 = Black
Symbol Ratios Code 39 Serial Cmd: Default: Options:
<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive
Codabar Serial Cmd: Default: Options:
<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive
Interleaved 2 of 5 Serial Cmd: Default: Options:
<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive
Composite Symbology Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required
Separator Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled
FIS-0870 Industrial Raster Scanner User’s Manual
A-37
Page 325
Separator (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> , (comma) Any 7-bit ASCII character
AIAG Serial Cmd: Default: Options:
<K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4,ID5a,ID5b, ID5c,status5,ID6,status6,ID7,status7,ID8,status8,ID9, status9,ID10, status10, ID11,status11,ID12,status12> 0 = Disabled 0 = Disabled 1 = Enabled
Depth of Field Enhance Serial Cmd: Default: Options:
<K456,mode> 2 = Medium 0 = Disabled 1 = Low 2 = Medium 3 = High
Code 39 Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 1 = Enabled 0 = Disabled 1 = Enabled
Check Character Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Check Character Output Status (Code 39) Serial Cmd: Default: Options:
A-38
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
FIS-0870 Industrial Raster Scanner User’s Manual
Page 326
Appendices Large Intercharacter Gap (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 10 1 to 128
Full ASCII Set (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Codabar Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Start/Stop Match (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled
Start/Stop Output (Codabar) Serial Cmd:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> FIS-0870 Industrial 1 Raster Scanner User’s Manual A-39 Default: = Enabled
Page 327
Options:
0 = Disabled
1 = Enabled
Large Intercharacter Gap (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 10 1 to 128
Check Character Type (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Both Mod 16 and NW7 (Mod 11)
Check Character Output (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Interleaved 2 of 5 Serial Cmd: Default: A-40
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled FIS-0870 Industrial Raster Scanner User’s Manual