The text of a manual · part 27 of 42
FIS-0870 Industrial Sweep Raster Scanner User's Manual: Scanner Parameters, pages 238 to 247
Pages 238 to 247 of 381, from FIS-0870 Industrial Sweep Raster Scanner User's Manual
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-0870
Page 238
Scanner Parameters
Wild Card Example: With Wild Card Character defined as the default asterisk, defining CR*34 as the master symbol will result in matches for CR134 and CR234, but not CR2345. Entering the wild card at the end of the master symbol, as in CR*, will result in matches for variable symbol lengths such as CR1, CR23, CR358, etc. Wild Card Character allows a user to define a wild card character as part of the master symbol.
FIS-0870 Industrial Raster Scanner User’s Manual
5-171
Page 239
Matchcode
Sequence on No Read Sequence on No Read is useful when the scanner needs to stay in sequence even if no decode occurs. When Sequence on No Read is Enabled and Matchcode Type is set to Sequential, the scanner sequences the master symbol on every match or No Read. When disabled, it does not sequence on a No Read.
Consider the following decodes as an example of Sequence on No Read Enabled: Master Symbol 001 002 003 004 005 006 007
Decoded Symbol 001 002 No Read 004 No Read No Read 007
Master Symbol after Decode 002 003 004 (sequence on No Read) 005 006 (sequence on No Read) 007 (sequence on No Read) 008
Consider the following decodes as an example of Sequence on No Read Disabled: Master Symbol 001 002 003 003 004 004 004
5-172
Decoded Symbol 001 002 No Read 003 No Read No Read 004
Master Symbol after Decode 002 003 003 (not sequenced) 004 004 (not sequenced) 004 (not sequenced) 005
FIS-0870 Industrial Raster Scanner User’s Manual
Page 240
Scanner Parameters
Sequence on Mismatch Note: Matchcode Type must be set to Sequential for this command to function. Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. When set to Enabled, the master symbol sequences on every decode, match, or mismatch. Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur. When set to Disabled, the master symbol will not sequence whenever consecutive mismatches occur. The scanner will sequence the master to one more or one less than the decoded symbol.
Consider the following decodes as an example of Sequence on Mismatch Enabled: Master Symbol 001 002 003 004 005 006 007
Decoded Symbol 001 002 abc 004 def ghi 007
Master Symbol after Decode 002 003 004 (sequence on mismatch) 005 006 (sequence on mismatch) 007 (sequence on mismatch) 008
Consider the following decodes as an example of Sequence on Mismatch Disabled: Master Symbol 001 002 003 004 005 006 006
Decoded Symbol 001 002 abc 004 def ghi 006
FIS-0870 Industrial Raster Scanner User’s Manual
Master Symbol after Decode 002 003 004 (sequenced because of previous match) 005 006 (sequenced because of previous match) 006 (not sequenced) 007
5-173
Page 241
Matchcode
Sequence Step When the master symbol is sequenced (incremented/decremented), Sequence Step defines the magnitude of change.
New Master Pin If Matchcode and New Master Pin are enabled and the new master pin is momentarily connected to ground (must be held low for a minimum of 10 ms), master symbol information will be loaded into the database based on the next read cycle that achieves a Good Read, starting with Index 1. The Master Database will be loaded with all symbols decoded in the read cycle as long as it does not exceed the Master Symbol Database Size parameter.
New Master Load Status The new master status responds with the number of the next master position to be loaded, where 0 represents “idle” or “no master to be loaded.” Example: If the user has the Master Symbol Database Size set to 1, and then either sends a <G> or toggles an active New Master Pin, the state will be 1, and prior to reading and effectively loading position 1, the response to <NEWM> would be <NEWM/1>. Once a symbol has been read and loaded, the status will be cleared: <NEWM/0>.
5-174
FIS-0870 Industrial Raster Scanner User’s Manual
Page 242
Scanner Parameters
Match Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a match occurs.
Mismatch Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs.
FIS-0870 Industrial Raster Scanner User’s Manual
5-175
Page 243
Diagnostics
Diagnostics Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Diagnostics tab to display the Diagnostics tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Matchcode settings can also be sent to the scanner from ESP’s Terminal using Wenglor’s K command format. Refer to Diagnostics.
5-176
FIS-0870 Industrial Raster Scanner User’s Manual
Page 244
Scanner Parameters
Counts (Read-only)
Power-On 16-bit counter that increments on scanner power-on. Used for detecting unwanted resets caused by power supply problems or ESD transients. Returns the number of times the scanner has been re-powered or a watchdog reset occurs. 0 to 65,535 power-ons.
Resets 16-bit counter that increments every time the scanner is reset. Value is reset on power-on. Used for detecting unwanted resets caused by power supply problems or ESD transients. Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware defaults. A watchdog reset is a reset that is forced whenever the software locks up. 0 to 65,535 resets.
Power-On Saves 16-bit counter that increments every time a scanner setting is saved for power-on.
Custom Default Saves 16-bit counter that increments every time a scanner setting is saved to the customer parameter section of flash memory.
FIS-0870 Industrial Raster Scanner User’s Manual
5-177
Page 245
Diagnostics
Hours Since Reset (Read-only) Used as a troubleshooting tool that can help pinpoint the cause of a reset. Records the number of hours and minutes of operation since the last system reset.
Hours 16-bit counter that increments every 60 minutes. Range: 0 to 23 hours.
Minutes 16-bit counter that increments every 60 seconds. Range: 0 to 59 minutes.
5-178
FIS-0870 Industrial Raster Scanner User’s Manual
Page 246
Scanner Parameters
Laser High When Enabled, a Laser High message is transmitted whenever the laser current exceeds a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Alerts the user to impending laser failure. (Contact Wenglor Service.)
Status Allows the user to Enable or Disable the Laser High message.
Message Defines the Laser High message.
FIS-0870 Industrial Raster Scanner User’s Manual
5-179
Page 247
Diagnostics
Laser Low When Enabled, a Laser Low message is transmitted whenever the laser current falls below a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Alerts the user to impending laser failure. (Contact Wenglor Service.)
Status Allows the user to Enable or Disable the Laser Low message.
Message Defines the Laser Low message.
5-180
FIS-0870 Industrial Raster Scanner User’s Manual