Page 228
Scanner Parameters
Diagnostics Note: Output On under Output 3 Parameters must be set to Diagnostic Warning for this output to function. Under Output 3 Parameters, expand the Diagnostics tree. When Diagnostic Warning is enabled, the Output On configuration has no effect. The output will remain active as long as one of the diagnostic warning conditions is met. The output will become inactive once it detects that there are no diagnostic warning conditions.
High Temperature Activates output when the temperature exceeds factory-defined upper limits.
FIS-0870 Industrial Raster Scanner User’s Manual
5-161
Page 229
I/O Parameters
Service Unit Allows the user to set up the output to toggle to active when the service timer has expired. This condition will only be held for one service timer click. Note: This feature cannot be used if the scanner is in Continuous Read. When Service Unit is enabled, a message of up to 10 ASCII characters is sent whenever the system detects that the service timer’s limit has been reached. The service timer is reset at power-on, meaning that the service timer’s limit is the amount of time since last reset. Service timer increments can be set in seconds or minutes.
5-162
FIS-0870 Industrial Raster Scanner User’s Manual
Page 230
Scanner Parameters
Laser Current High Activates output when the laser current exceeds factory-defined upper limits.
Laser Current Low Activates output when the laser current drops below factory-defined lower limits.
FIS-0870 Industrial Raster Scanner User’s Manual
5-163
Page 231
I/O Parameters
Low Temperature Activates output when the temperature drops below factory-defined lower limits.
5-164
FIS-0870 Industrial Raster Scanner User’s Manual
Page 232
Scanner Parameters
Quality Output
Quality Output Separator The separator character separates quality output data from symbol data.
Decodes per Trigger Status When Enabled, the scanner enters a state where it processes frames as configured until the end of a read cycle, with or without a successful symbol decode. When the read cycle ends, the scanner outputs any decoded symbol data along with the decodes per trigger count.
Decode Direction Output When Enabled, compares the symbol decode direction to the direction specified in Output Filter Configuration.
FIS-0870 Industrial Raster Scanner User’s Manual
5-165
Page 233
I/O Parameters
Symbol Position Output
Raster Status Scan Status When Enabled, the location of the symbol within the scan line is appended to the symbol data output. The scan position is formatted with a leading identifier of “SP” plus two zero-padded three digit numbers (corresponding to the first and last bar of the symbol for most symbologies), separated by a colon. The scan position values correspond to the configurable Laser On/Off position values in the Laser Setup command. Example: Assume a symbol with the data “HELLO” is read when its first bar is at 25% of the scan width and its last bar is at 85% of the scan width. The data output would be HELLO SP025:085, assuming that no other outputs or formatting were enabled.
Separator This character separates all other symbol information from the Scan Status data field.
5-166
FIS-0870 Industrial Raster Scanner User’s Manual
Page 234
Scanner Parameters
Matchcode Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Matchcode tab to display the Matchcode tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Matchcode settings can also be sent to the scanner from ESP’s Terminal using Wenglor’s K command format. Refer to Matchcode.
FIS-0870 Industrial Raster Scanner User’s Manual
5-167
Page 235
Matchcode
Overview of Matchcode Matchcode allows the user to store master symbol data in the scanner’s memory, compare that data against other symbol data, and define how symbol data and/or discrete signal output will be directed. A master symbol database can be set up for up to 10 master symbols. Note: Matchcode will function with multiple symbols; however, if Matchcode Type is set to Sequential or if Trigger Mode is set to Continuous Read 1 Output, the scanner will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration. Matchcode is used in applications to sort, route, or verify data based on matching the specific symbol in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the symbol.
Steps for Entering and Using Master Symbols • Set Trigger Mode to External Level, External Edge, or Serial Data. • Choose the method of symbol comparison that fits the application. • Define the type of output required with Matchcode setup: Symbol data output; Discrete output • Select the number of master symbols required. • Decide how the master symbol(s) will be entered: Use ESP to type master symbol data directly; Send a serial command with symbol data in the form of <M231,master symbol#, data>; Send a <G> (Read Next Symbol as Master Symbol) command; Enable the New Master Pin command and activate the discrete input to store the next symbol read as the master symbol.
5-168
FIS-0870 Industrial Raster Scanner User’s Manual
Page 236
Scanner Parameters
Matchcode Type Allows the user to choose the way that master symbols will be compared with subsequently read symbols. Note: First set Trigger Mode to External Level, External Edge, or Serial Data.
Sequential Instructs the scanner to compare symbols or portions of symbols with the master symbol. Instructs the scanner to sequence after each match (numeric only) and compare symbols or portions of symbols for sequential numbers.
Wild Card Allows the user to enter user-defined wild card characters in the master symbol. Note: If Matchcode Type is set to Sequential, the scanner will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.
Sequential Matching Useful in tracking product serial numbers that increment or decrement sequentially. With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order.
FIS-0870 Industrial Raster Scanner User’s Manual
5-169
Page 237
Matchcode
Match Start Position Match Start Position is useful in defining specific portions of a symbol for comparison. For example, if a symbol contains a part number, manufacturing date, and lot code info, but only the part number information is needed, set the scanner to sort only the part number and to ignore the other characters. Match Start Position determines the portions of symbols that will be matched by defining the first character in the symbol (from left to right) that will be compared with those of the master symbol, when Matchcode Type is set to Enabled or Sequential. For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length. Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.
Match Length Example: If Match Length is set to 6 in a 10-character symbol, and Match Start Position is set to 2, only the 2nd through 7th characters (from left to right) will be compared. Defines the length of the character string that will be compared with that of the master symbol when Match Start Position is set to 1 or greater. When Match Start Position is set to 0, no comparison will occur.
5-170
FIS-0870 Industrial Raster Scanner User’s Manual