Page 188
Scanner Parameters
Two Beeps Hold down button until two quick beeps are heard (and the 20% and 40% LEDs illuminate.)
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To cancel Bar Code Configuration, quickly press and release the EZ Button.
FIS-0870 Industrial Raster Scanner User’s Manual
5-121
Page 189
I/O Parameters
Three Beeps Hold down button until three quick beeps are heard (and the 20%, 40%, and 60% LEDs illuminate).
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
5-122
FIS-0870 Industrial Raster Scanner User’s Manual
Page 190
Scanner Parameters
Four Beeps Hold down button until four quick beeps are heard (and the 20%, 40%, 60%, and 80% LEDs illuminate).
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
FIS-0870 Industrial Raster Scanner User’s Manual
5-123
Page 191
I/O Parameters
Auto Framing Options When Enabled, Laser Framing is performed when the Auto Framing button beep position is selected (Single Beep, Two Beeps, Three Beeps, or Four Beeps).
5-124
FIS-0870 Industrial Raster Scanner User’s Manual
Page 192
Scanner Parameters
Status Indicators The side of the FIS-0870 features an array of LEDs that indicate various aspects of scanner activity. Controls the operation of the MOD/ACT and NET/LNK LEDs. Note: MOD and ACT function as one combined LED, as do NET and LNK.
Disabled When set to Disabled, the MOD/ACT and NET/LNK LEDs are always off. Note: All green and red LEDs will turn on briefly during power-on or reset to confirm that they are functioning.
PHY Activity If Ethernet is available: LNK = Solid green when transceiver is linked. ACT = Blinking green when transceiver detects Tx or Rx activity. Otherwise, for all RS232 and RS422/485 activity: LNK = Blinking green with Tx data activity. ACT = Blinking green with Rx data activity. Note: Red is never turned on.
Protocol Activity If EtherNet/IP is enabled: MOD = Module status, per EtherNet/IP specification NET = Network status, per EtherNet/IP specification Otherwise, the MOD and NET LEDs are always off.
FIS-0870 Industrial Raster Scanner User’s Manual
5-125
Page 193
I/O Parameters
Bar Graph Read Rate, Auto Calibration, Bar Code Configuration, and Read Cycle Result all share the Bar Graph (20% – 100%) LEDs.
I/O 1 I/O 1 always shows the combined state of the discrete outputs. If any output is active, the I/O 1 LED will be on.
I/O 2 I/O 2 always shows the state of the hardware input trigger. If the trigger is active, I/O 2 will be on.
5-126
FIS-0870 Industrial Raster Scanner User’s Manual
Page 194
Scanner Parameters
Calibration Options Calibration Options specifies the operation of the calibration feature. The default configuration is set up to perform calibration on Gain, Focus and Symbol Type.
Video When set to Calibrate, there will be an attempt to change Video settings (Gain and Tracking). Video settings include Gain and Tracking.
Scan Speed When set to Calibrate, there will be an attempt to change Scan Speed. If a better read rate at a different speed is found, the new speed will be the calibration result for Scan Speed.
Laser Power When set to Calibrate, there will be an attempt to change Laser Power. If a better read rate at a higher power is found, or if the same read rate at a lower power is found, the new power level will be the calibration result for Laser Power.
FIS-0870 Industrial Raster Scanner User’s Manual
5-127
Page 195
I/O Parameters
Laser Framing When set to Calibrate, there will be an attempt to frame the symbol automatically. Framing is based on symbol readability. The frame line will be decreased until a drop in read performance is detected. Once the line length is found then a small margin is added to account for variation.
Symbol Type When set to Calibrate, all supported symbologies (except PDF417 and Pharmacode) will be attempted during calibration. Symbol lengths are not detected. Any new symbologies successfully decoded during calibration will remain enabled at the end of the process. All enabled symbologies will remain enabled. For example, assume that only Code 39 is enabled at the beginning of calibration. If a Code 128 symbol is read during calibration, then Code 128 as well as Code 39 will be enabled at the end of calibration.
5-128
FIS-0870 Industrial Raster Scanner User’s Manual
Page 196
Scanner Parameters
Database Identifier Output Useful in tracking which database entries read which symbols.
Database Identifier Output Status
Disabled When this command is disabled, no database identifier information will be output.
Enabled When this command is enabled, the scanner will append a two-digit number and the characters “DB” to the data output following the separator for each symbol decoded using Configuration Database. For example, if the separator is an underscore character and the second database entry reads a symbol encoded with “data capture” during the read cycle, the symbol data output will be “data capture_DB02”. If the database is not active, no identifiers will be attached to output.
Separator Character The separator character separates the symbol data from the database identifier.
FIS-0870 Industrial Raster Scanner User’s Manual
5-129
Page 197
I/O Parameters
Input 1
Input Mode Determines the function of the Input pin.
Disabled When set to Disabled, the Input pin has no impact on operation.
Reset Counts When set to Reset Counts, a transition to the active state of the Input will cause the scanner to reset the internal counters.
Unlatch Output This setting is used in combination with any of the three outputs in Latch Mode 1 (Unlatch Input # 1 Pin). A transition to the active state will clear any of the three outputs that were previously latched.
Active State
Active Open Input function is activated when input state is de-energized.
Active Closed Input function is activated when input state is energized.
5-130
FIS-0870 Industrial Raster Scanner User’s Manual