The text of a manual · part 21 of 42
FIS-0870 Industrial Sweep Raster Scanner User's Manual: Scanner Parameters, pages 178 to 187
Pages 178 to 187 of 381, from FIS-0870 Industrial Sweep Raster Scanner User's Manual
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-0870
Page 178
Scanner Parameters
No Symbol Message Useful in determining if a symbol is present and if user defined requirements for that symbol are met. Can tell the user if an object does not qualify as a symbol. Sets the requirements that will qualify an object or a symbol before outputting a decode or message. When enabled, sends a message to the host whenever an object meets the qualifications setup but is not decoded. Note: When Symbology Identifier is enabled, the No Symbol Message is preceded by the identifier for the symbology being used.
Message Any combination of ASCII characters can be defined as the No Symbol Message.
FIS-0870 Industrial Raster Scanner User’s Manual
5-111
Page 179
I/O Parameters
Read Duration Output Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed (obtainable based on spacing between symbols.) When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output. Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days’ worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration.
Separator User-defined character that separates the symbol information from the Read Duration Output.
5-112
FIS-0870 Industrial Raster Scanner User’s Manual
Page 180
Scanner Parameters
Output Indicators
The FIS-0870 has a beeper and two LED arrays, as follows: • An array of green LEDs projected from the front of the scanner that can be programmed to flash in response to user-defined conditions. • An array of status LEDs on the side of the scanner.
Green Flash Mode
Used as a visual verification that a good read has occurred. An array of green LEDs in the front of the scanner can be programmed to flash in response to user-defined conditions.
Disabled Green flash LEDs are disabled.
On Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs.
FIS-0870 Industrial Raster Scanner User’s Manual
5-113
Page 181
I/O Parameters
Static Presentation Static Presentation Mode is used in conjunction with Continuous Read mode. When operating in Static Presentation Mode, the red LEDs will illuminate while the scanner is searching for a symbol in Continuous Read mode. When a symbol is placed in the field of view and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the scanner is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: • Enable Continuous Read. • Select the number of symbols. • Enable Static Presentation in Green Flash Mode. • Select the read time in Green Flash Duration.
Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a good read.
Mismatch Same as Match, except that LEDs will illuminate on a mismatch.
5-114
FIS-0870 Industrial Raster Scanner User’s Manual
Page 182
Scanner Parameters
Green Flash Duration Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value.
Beeper An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. Note: The beeper will also sound at any of the following times: • When the scanner is defaulted. • When a Send and Save command is sent from ESP. • At the conclusion of an Auto Calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent from ESP’s Terminal.
FIS-0870 Industrial Raster Scanner User’s Manual
5-115
Page 183
I/O Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status This command is useful in removing any doubt about the scanner’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1,START> is entered, the scanner will echo back <K701,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. Host Scanner If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.
Serial Command Beep Status Used to audibly verify the acceptance and validity of a command. Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.
5-116
FIS-0870 Industrial Raster Scanner User’s Manual
Page 184
Scanner Parameters
Control / Hex Output Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M.
FIS-0870 Industrial Raster Scanner User’s Manual
5-117
Page 185
I/O Parameters
EZ Button Serves as a master switch to enable/disable the EZ Button status.
The EZ Button has four positions: Single Beep, Two Beeps, Three Beeps, and Four Beeps, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight EZ Button Modes.
5-118
FIS-0870 Industrial Raster Scanner User’s Manual
Page 186
Scanner Parameters
EZ Button Status
Disabled When set to Disabled, the EZ Button does not function.
Enabled When selected, the EZ Button is enabled and the function of each button position is selected by the EZ Button Modes command.
Trigger When selected, the EZ Button acts as a trigger for the scanner to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:
The read cycle endures for as long as the EZ Button is pressed, unless a timeout occurs and End of Read Cycle Mode is set to Timeout. As with External Level, External Edge allows a read cycle to be initiated by pressing the EZ Button, but unlike External Level, the read cycle ends with a good read output, a timeout, or a new trigger.
Unlatch Outputs In this configuration, the EZ Button will unlatch any logic outputs that have been latched.
Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.
Default on Power-On When enabled, if the EZ Button is held down on power-on, the scanner will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command from ESP’s Terminal.
FIS-0870 Industrial Raster Scanner User’s Manual
5-119
Page 187
I/O Parameters
EZ Button Modes Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ Button’s 4 positions from a selection of 8 modes.
Single Beep Hold down button until a single beep is heard (and the 20% LED illuminates).
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button. 5-120
FIS-0870 Industrial Raster Scanner User’s Manual