Page 9
CCD Setup & Configuration, Set Default Configuration
The 'Set Default' configuration restores the factory default settings. Tip: Use this option to restore the factory default settings if you are unsure of your CCD’s configuration. The 'Set Default' configuration is very useful when you need to reprogram your Wasp CCD reader after the defaults have been changed. By setting the default configuration, the user knows precisely the configuration for each programmed setting.
Begin
Default
End
6
Page 10
CCD Setup & Configuration, Preamble/Postamble Configuration
The 'Preamble/Postamble' configuration is used to add a prefix or suffix set of characters to the bar code value. Up to 4 characters may be added for each option separately. Preamble and postamble characters can function concurrently, but need to be configured separately. To add preamble or postamble characters, follow the steps below: (1) Scan the 'Begin' bar code on this page (2) Scan the 'Preamble' or 'Postamble' option (3) Use Appendix B on page 23 to locate the characters you want to add as preamble or postamble characters. Find the two character 'Code' associated with the character you want to add. Scan the two characters on page 25. Make sure that you scan the two bar codes associated with each letter before preceding to the next character. This step can be repeated up to six more times - seven total. For example, to add the letter "A," scan the "4," and then the "1" on page 25. The letter "A" will always appear in your data as a prefix or suffix to the bar code value. (4) Scan the 'Set' option at the bottom of this page. (5) Scan the 'End' bar code on this page.
Begin Preamble Note: Please use Appendix B regarding the prefix string. You may add up to 4 characters as a Preamble.
Postamble Note: Please refer to Appendix B regarding the suffix string. You may add up to 4 characters as a Postamble.
Set
End
7
Page 11
CCD Setup & Configuration, CCD Audio Configuration:
Begin
Low
Scanner Volume
High*
On*
Beep On/Off
Off
End
8
*Default
Page 12
CCD Setup & Configuration, Keyboard Setting Configuration
The 'Case Sensitivity' setting provides specific options on how to pass your data to the keyboard buffer. 'Case Sensitive' is the default and does not toggle upper to lower case letters. 'Ignore Case' transmits only lower case letters. Either 'Case Sensitive' or 'Ignore Case' can be enabled, but not both simultaneously.
Begin
Case Sensitive*
Case Sensitivity
Ignore Case
End
*Default
9
Page 13
CCD Setup & Configuration, CCD Scanning Control Configuration
The 'CCD Scanning Control' configuration allows the user to customize how the trigger is to operate, the length of time in which the LEDs (i.e. the CCD photodetectors) are on, and activates auto scanning. The Wasp CCD has two (2) options to control this configuration. Only one option can be enabled at a time. Note: When the LEDs are visible, the CCD scanner can read the bar code symbologies that are enabled. See 'Enable Bar Code Symbologies' for further information.
Begin
On/Off Trigger with 7 Second Delay When this option is selected, the LEDs become visible when the trigger is pressed, and will remain on for 7 seconds. The LEDs will turn off automatically after 7 seconds whether a bar code is successfully scanned or not or if the trigger is pressed again.
On/Off Trigger - 7 Second Delay*
Continuous Scan When this option is enabled, the LEDs are always visible and the CCD reader will operate continuously without the need of using the trigger. This mode will read identical bar code values back-to-back.
Continuous Scan
End
10
*Default
Page 14
CCD Setup & Configuration, Enable Bar Code Symbologies Configuration
The 'Enable Bar Code Symbologies' configuration is used to enable or disable the various codes that the reader is able to scan. Multiple bar code symbologies can be enabled simultaneously.
Begin ON
OFF
Code 39
*
Interleaved 2 of 5
*
Codabar
*
UPC-A
*
UPC-A 2 digit add-on
*
UPC-A 5 digit add-on
*
UPC-E
*
UPC-E 2 digit add-on
*
UPC-E 5 digit add-on
*
Code 93
*
End
11
*Default
Page 15
CCD Setup & Configuration, Enable Bar Code Symbologies Configuration
The 'Enable Bar Code Symbologies' configuration is used to enable or disable the various codes that the reader is able to scan. Multiple bar code symbologies can be enabled simultaneously.
Begin ON Code 128
OFF
*
MSI
*
EAN/8
*
EAN/8 2 digit add-on
*
EAN/8 5 digit add-on
* *
EAN/13
EAN/13 2 digit add-on
*
EAN/13 5 digit add-on
*
End
12
*Default
Page 16
CCD Setup & Configuration, Code 39 Configuration
Code 39 is the most frequently used symbology in industrial bar code systems today and is extensively used within the Department of Defense (DOD). The principal feature is to encode messages using the full alphanumeric character set. The Code 39 bar code uses four special characters "$", "/", "+". "%" which can be paired with alphanumeric characters to extend to the full ASCII character set. Standard Code 39 contains only 43 characters (0-9, A-Z, $, /, %, +, -, ., SPACE) and can be extended to a 128 character symbology (full ASCII) by combining one of the special characters ($, /, %, +) with a letter (A-Z) to form the characters that are not present in the standard Code 39 symbology.
Begin
Standard Type
*
Type Full ASCII
Transmit Start/Stop Character
No
*
Yes
No
*
Verify Checksum Yes
Transmit Check Character
No Yes
*
End
13