Page 1

CCD Programming Guide for Wasp Bar Code CCD Scanner

Please Read

Note: The Wasp CCD Scanner is ready to scan the most popular bar codes out of the box. This manual should only be used to make changes in the configuration of the scanner for specific applications. This scanner does not require software or drivers to operate. The scanner enters data as keyboard data. Please review this manual before scanning any of the programming bar codes in this manual.

Tech Tip If you are unsure of the scanner configuration or have scanned the incorrect codes, please scan the default bar code on page 6. This will reset the scanner to its factory settings.

Page 2

© Copyright Wasp Technologies All rights reser ved. Version 2.0 No part of this publication may be reproduced or transmitted in any form or by any means without the written permission of Wasp Technologies. The information contained in this document is subject to change without notice.

Wasp is a trademark of Wasp Technologies. All other trademarks or registered trademarks are the property of their respective owners .

Page 3

Table of Contents Chapter 1. Chapter 2. Chapter 3. Chapter 4. Chapter 5.

Appendix A. Appendix B. Appendix B. Appendix C.

Introduction..............................................................................1 Installation................................................................................2 Quick Start ..............................................................................3 Bar Code Symbologies............................................................4 CCD Setup & Configuration ..............................................5-19 1. Set Default ..............................................................6 2. Preamble/Postamble ..............................................7 3. CCD Audio Configuration........................................8 4. Keyboard Setting ....................................................9 5. CCD Scanning Control ........................................10 6. Enable Bar Code Symbologies........................11-12 7. Code 39................................................................13 10. Interleaved 2 of 5..................................................14 11. Codabar................................................................15 12. UPC-A ..................................................................16 13. UPC-E ..................................................................17 14. EAN/JAN-13..........................................................18 15. EAN/JAN-8............................................................19 Bar Code Test Symbols....................................................20-22 Preamble/Postamble Addition Table ................................23-25 Preamble/Postamble Special Characters..............................26 Additional Scanner Functions................................................27

Product Support ..............................................................................................28 Warranty ..............................................................................................28

Page 4

Chapter 1

Introduction Bar coding is the most common Automated Data Collection (ADC) technology providing timely, error-free information that can be used to increase productivity, accuracy, and efficiency in the workplace. Virtually every type of industry is using bar codes to replace keyboard data entry. Studies have shown that a proficient data entry operator will make one error for every 300 characters that are manually entered. The error rate using bar codes is almost negligible and can be error-free using bar code symbologies with the check digit enabled. The Wasp Charged Coupled Device (CCD) technology is a technique whereby a bar code is photographed, digitized, and electronically sampled by built-in photodetectors. The detectors process the measurement of every bar and space using the number of adjacent photodetectors which contrast a black mark and a white space. The Wasp CCD is extremely rugged since it has no moving parts. The Wasp CCD reader supports PC AT/XT and PS/2 keyboard interfaces and easily wedges between the computer and keyboard. Bar code data is passed directly into the keyboard buffer as if it had been typed in by hand by a data entry operator. Of all the hand held, bar code scanning devices on the market, the CCD reader is the easiest to use and most cost effective for the typical business user. The Wasp CCD scanner is a one touch scanner allowing the user to come in direct contact with the bar code. It also supports a depth of reading of up to 1.4 inches to successfully decode a bar code symbology. Bar codes up to 2.75 inches in length can be scanned. To activate the scanner, the user simply covers the bar code with head of the scanner and pulls the trigger. The Wasp CCD supports a scan rate of 50 scans per second.

1

Page 5

Chapter 2

Installation Keyboard Wedge Cable

Scan Feedback Indicator

Keyboard Y-Cable Trigger Scanning Aperture

Din-6 Din-5

Side View

(PC Only)

Scanning Aperture

Trigger

Bottom View 1. 2. 3.

4.

Turn off your computer. Plug the keyboard wedge cable into the handle of the CCD reader. Unplug your PC keyboard cable and plug the male end (Din 5) of the Wasp CCD scanner directly into your PC keyboard port. Plug your keyboard cable into the other end (female Din 5) of the the Wasp CCD scanner. If your keyboard and PC support a Din 6 connection, use the enclosed Din 5 to Din 6 converter cables. Turn your computer on. Note: Make sure scanner is not plugged into the mouse port. Scanner will not function properly if plugged into the mouse port.

2

Page 6

Chapter 3

Quick Start Your Wasp CCD Scanner is ready to go.The default settings of the Wasp CCD Scanner have been pre-programmed for the most common bar code configurations. Use the "CCD Setup & Configuration" sections only to customize the Wasp CCD settings. Please review the 'Enable Bar Code Symbologies' configuration on pages 11 and 12 to see the list of bar code symbologies which are enabled by default. Tip: Use the pre-printed "Bar Code Test Symbols" in Appendix A on page 20 as a test chart to begin practicing scanning.

3

Page 7

Chapter 4

Bar Code Symbologies Bar codes are symbols consisting of a series of bars and spaces which can be applied to packages, cartons, bottles, and other commercial products. The bars and spaces in each symbol are grouped in such a way to represent a specific ASCII character or function. The interpretation of these groups is based on a particular set of rules called symbologies. Various symbologies have been developed for particular applications. Some examples are shipping and receiving, manufacturing, retail, healthcare, transportation, document processing, tracking, and libraries. The resolution of a bar code is dependent on the narrowest element of a bar code (X dimension), and can vary from high density (nominally less than 0.009 in./0.23 mm), medium density (between 0.009 in./0.23 mm and 0.020 in./0.50 mm), and low density (greater than 0.020 in./0.50 mm). Medium and low densities are the most common since these are the easiest to read (scan) with nearly all scanning devices. The Wasp CCD scanner can read bar codes with X-dimensions as low as 5 mils (0.005 in./0.127 mm). The Wasp CCD scanner can read the most popular bar code symbologies including Code 39, Code 128, Interleaved 2 of 5, UPC-A, UPC-E, EAN/JAN-8, EAN/JAN-13, Codabar, MSI Plessey, and Code 93. Please see test chart on page 20.

4

Page 8

Chapter 5

CCD Setup & Configuration In order to configure the Wasp CCD scanner, you must familiarize yourself with the setup procedures on the following pages. The default settings of the Wasp CCD scanner are identified on each page and clearly marked with an asterisk (*). The default settings have been preprogrammed for the most common bar code configurations. Use the CCD Setup & Configuration only to customize the Wasp CCD settings. If you need to configure the Wasp CCD reader, the default settings will be overwritten. All the programmed settings are stored permanently in non-volatile memory. Therefore, your configuration will be maintained even if keyboard power to the Wasp CCD scanner is removed by turning off your PC. In order to configure the Wasp CCD, three basic steps need to be followed for each programmed setting: (1) Scan the 'Begin' bar code with the Wasp CCD reader to select your configuration (2) Scan the appropriate setting(s) to customize the CCD configuration (3) Scan the corresponding 'End' bar code with the Wasp CCD reader

Note: If you are unsure whether or not you have programmed the scanner properly, return to page 6 and return the scanner back to the default settings. Then begin the configuration process again.