For the Videx TimeWand II

Page 151

Bar Code Reference Where to Get Bar Codes Printed sheets of high quality “peel-off” labels containing various bar codes are readily available from the vendors listed in Appendix A. The bar codes can be organized in many different ways to meet the requirements of numerous applications. It is important that high-quality bar code labels be used for best reading results.

Bar Code Optimum Size Bar code size can be specified by the width of the narrow bars and spaces, which should be equal to each other. Videx recommends that you use bar codes with this narrow element width equal to 15 thousandths of an inch. This size corresponds to about 5 bar code characters per inch. Be sure to include the start and stop characters when calculating characters per inch. Good performance cannot be guaranteed with a narrow element width of less than 10 thousandths of an inch. However, the TimeWand II can usually read goodquality, high-contrast bar codes with narrow elements of 8.5 thousandths of an inch (9 characters per inch). It usually cannot read bar codes with minimum dimensions of 5 thousandths or less.

*a10002* 0.015 narrow element width

Chapter 4 TimeWand II Reference

147

Page 152

Bar Code Symbologies There are many different bar code symbologies. The following chart shows some of the most commonly used symbologies.

Ba r C ode

U se s

D e scription

Auto parts, labels for sorting, Dept. of Defense, purchasing, and supply control

The most popular industrial and government bar code symbology. Reliable. Variable length bar code with both numeric and uppercase letters.

Interleaved 2 of 5

Industry, cartons of food, labels for sorting, and supply control

A popular industrial bar code symbology. This is a numbers only code and requires an even number of digits to make a legal code.

EAN

European product code

European retail code symbology.

UPC

Universal Product Code; grocery, drug, and medical goods

A food and drug retail market symbology. This is a variable length code.

Medical sample control, photo processing, and libraries

Used for Red Cross blood banking. This is a variable length code.

Shipping/receiving, inventory

A popular high-density bar code symbology. Variable length with upper and lowercase letters, all ASCII control characters, and all numeric entries.

Code 3 of 9

Codabar

Code 128

Figure 4-3 Bar Code Symbologies Before you use a TimeWand II, you should identify the type of bar code symbology you are using. TimeWand IIs can be programmed to read all of the listed symbologies and to store the type of bar code (Origin of Data number) with each scan.

148

Chapter 4 TimeWand II Reference

Page 153

TimeWand II Maintenance and Troubleshooting •

Do not expose your TimeWand II to temperatures in excess of 120°F (for example a car dashboard on a sunny day, or any direct sunlight for extended periods).

•

Do not allow the TimeWand II to get wet. Being caught occasionally in a light shower won’t cause any problems if you wipe the wand off promptly and allow it to dry. Avoid immersion, long-term exposure to high humidity, or regular exposure to rain.

If You Have Trouble If your TimeWand II does not sound a “good read” tone when you scan a bar code and you are sure that the TimeWand II has a good battery charge, one or more of the following things may be wrong: • The bar codes may be an unreadable bar code symbology (see the chart on page 143). • The scan may be improperly performed. The scan should be made at a steady, moderately fast speed; the scan should start well within the white space preceding the code and should sweep completely through the bar code without going off the top or bottom of the bar code. • The bar code contrast or printing quality may be inadequate. See the detailed troubleshooting section on bar code quality for further information. • The bar code may be smeared or otherwise unreadable. • The TimeWand II’s battery pack may need replacement. • The TimeWand II may have an internal component malfunction. • You may be attempting to use an incorrect or non-functional user application. Chapter 4 TimeWand II Reference

149

Page 154

Detailed Troubleshooting Check Power: Before you attempt to recharge a wand that is completely discharged, you should try to insure that power is actually available to it. First make sure that the transformer is plugged into a working electric outlet and the Power light on the recharger/downloader is on. Press and hold any button on the TimeWand II; the letters “CHG” should appear on the second line of the display. If you do not get this indication, power is not reaching the recharger/downloader’s connector. If you have access to a test voltmeter, you can use it to measure the voltage on the connector pins. The pin nearest the edge of the connector is the negative side, and the voltage should be about 18 volts DC. In the case of a wand with data still in it, do NOT assume that failure to respond is an indication of data loss until you have been able to verify the presence of power. You should verify that the electric outlet is working by testing it with another electric device such as a radio or lamp and recheck everything. If there is no response from the wand after leaving it in the recharger/downloader for one hour, contact the Videx Technical Support Department for advice.

150

Chapter 4 TimeWand II Reference

Page 155

Data is Lost: When the battery voltage gets low the TimeWand II will not operate, preserving what is left of the battery power for a short time. In some cases this means that your data is still intact even though the wand has quit working because of a low battery. Since the battery eventually gets low enough to erase the memory, do not delay in transferring the data and recharging the wand. Promptly transferring the data after it is collected is the best way to prevent the possibility of data loss due to battery discharge. If you have attempted to recharge a wand, with no response for two minutes, and you have verified that power is available at the recharger/downloader’s connector, it is likely that the data has been lost due to excessive discharge of the batteries or malfunction of the wand. A reset and recharge often returns it to proper operation. If the data is difficult or impossible to reconstruct, contact the Videx Technical Support Department for assistance.

Chapter 4 TimeWand II Reference

151

Page 156

Check Cable, Serial Hardware, and Resident Software: If there is no response from the serial port, there are several possible causes. First check that all connections are securely connected. Try removing and inserting the TimeWand II into the recharger/downloader a few times. If there is still no response from the serial port, try using the same serial port with another piece of equipment and software that has worked before. A modem or direct connection to another computer with two-way communication is ideal, but a printer verifies at least outbound communication. If this test verifies that the serial port is functioning properly, there are two candidates for the cause of the problem. The first is the cable. If you have another cable of the same type, substitute it and run the tests again. If you have access to an ohmmeter or continuity checker, test the cable continuity using the cable diagrams in Appendix B. If you have none of these resources, contact the Videx Technical Support Department. Another possibility to consider is software interference from resident software modules. The large variety of these resident programs presents many opportunities for problems. First try removing all of them from your system. Check your AUTOEXEC.BAT file to make sure you catch them all. Device drivers installed in a CONFIG.SYS file can also cause problems. One way to be sure is to rename these two files so you can restore them easily, construct a minimum CONFIG.SYS using FIXCONF.BAT, and reboot the system. Try running the software in this bare system. If it runs now and did not before, there is a software conflict. Try adding the resident software back one program at a time. When the problem reappears, it pinpoints the program causing the problem. If the offending program has an unload option, you may be able to load it last and remove it whenever you need to use the TimeWand II software.

152

Chapter 4 TimeWand II Reference

Page 157

Bar Code Quality: Bar code symbols of poor quality reduce the read rate or in extreme cases are unreadable. Quality includes such elements as good contrast, clean printing, and correct dimensions. Contrast may be difficult to evaluate. The background must appear white and the code elements must appear black when illuminated by the light of the read head. This is particularly difficult to judge when you are using the optional infrared read head. Some types of ink do not appear black in infrared light and some types of paper, notably directly-printed thermal paper, do not produce good contrast in infrared light even though they do appear to have good contrast in visible light. A good test of contrast is to make a normal-sized, clean photocopy of the bar code with the density adjusted so the copy appears identical to the original. If the TimeWand II reads the copy but not the original, it is very likely that there is not enough contrast in the original. The standard visible light read head is less sensitive to contrast changes with wavelength, but may also have difficulty reading bar codes printed on thermal paper. The same photocopy test can be used. A worn impact printer ribbon can also cause loss of contrast. Any inked ribbons used to print bar codes must be renewed promptly when code darkness begins to diminish. The printing must be clean and have the correct dimensional relationships. Ragged edges, white specks in the bars, and black specks in the spaces or quiet zones at the beginning and end of the bar code reduce the reading performance. The narrow bars should be the same width as the narrow spaces, and likewise for the larger elements. The ratios between bars of different widths should be the values specified by the appropriate standard. Although the operating system symbology program can compensate for a certain amount of deviation from nominal values, extreme deviation from the standards produces unreadable bar codes.

Chapter 4 TimeWand II Reference

153

Page 158

TROUBLESHOOTING Chart 1 START

V y

Is battery pack reset switch installed? on ?

n

Turn switch Reset off. wand. Wait 5 sec.

Install Turn on battery. switch

Third time here ?

n

R y y Is a Program loaded in the Wand ?

n

Does display read "baud rate test. ." ? y y

Is display on at all ?

n

Go to n

PROGRAM WAND Chart 3

Does pressing key make display appear ?

n

Go to RECHARGE WAND Chart 2

V y Go to TEST OPERATION Chart 4

154

Chapter 4 TimeWand II Reference

Contact Videx Technical Support

Page 159

TROUBLESHOOTING Chart 2 Chart 4

Connect Wand to recharger. Check power. (See text)

Is there data in the Wand ?

RECHARGE WAND* y

Go to TEST OPERATION

Recharge 16 hours

Do Not move reset Recharge wand switch. Try recharge for 2 minutes. for 2 minutes Press any maximum. button.Press any Button.

Transfer data n

Data is probably lost. (See text)

Turn reset switch off. Wait 5 sec.

In y that time does "Cable connected" n appear ?

Turn reset Reset wand.on switch n

Three n beeps and "baud rate test. ." display ? y

Turn switch off. Charge 2 - 8 hours (up to 24 hours total).

Max time ?

y

Contact Videx Technical Support

Chart 3 Go to

Recharge 16 hours. (May be done after programming)

PROGRAM WAND

* This recharge procedure only for wands not operating correctly.

Chapter 4 TimeWand II Reference

155

Page 160

TROUBLESHOOTING Chart 3

PROGRAM WAND

R Chart 1 n

Start load operation on host computer.

Turn switch off. Reset Wait 5 sec. wand. Turn switch on.

Does display change to show proper baud rate ? n

Are there eight clicking sounds ?

y y

Check serial ports. (See text)

y n

Is "Loading. ." displayed while program loads ? y n

Is message sequence completed (See text) ? y

Solution ? n y Solution ?

Check cable, serial hardware, and resident software. (See text)

n

Contact Videx Technical Support

Make sure loading has not been interrupted

Go to TEST OPERATION Chart 4

156

Chapter 4 TimeWand II Reference