Page 141

TimeWand II Read Head TimeWand II is available with either a standard 700 nanometer (nm) near-visible light read head or optional 820 nm infrared or 655 nm visible light read heads. A 700 nm read head falls at the very edge of the visible light range. It can read the widest variety of bar codes; it can read some masked bar codes, some high-density bar codes, and some direct thermal printed bar codes. A 655 nm read head is in the visible light range. Bar codes printed with a variety of printers, including direct thermal, can be read by this read head. The 655 nm read head may also read other bar codes where contrast has been a problem, such as bar codes printed by an ink-jet printer. An 820 nm read head is in the infrared light range, not visible to the human eye. This read head reads all masked bar codes, and frequently reads higher density bar codes than the other read heads. An 820 nm read head reads bar codes printed by a variety of printers, but not direct thermal printed bar codes.

Chapter 4 TimeWand II Reference

137

Page 142

All three read heads read thermal transfer printed bar codes. The following table shows which optics work best for various printing methods. Bar Codes

Visible Optics

Near-Visible Optics

Infrared Optics

655 nm

700 nm

820 nm

Direct Thermal Thermal Transfer Laser Printed Ink-Jet Printed Higher

Clear Opaque

Bar codes with smallest dimension less than 0.0075". Can read some bar codes of this type; testing recommended before purchase. Maximum laminate thickness is 5 mils; 3 mils is recommended.

We recommend using the standard 700 nm read head for a TimeWand II unless you have a special need for one of the optional read heads. The read head is protected by a sapphire scan tip which keeps the read head clean and protects it from damage.

138

Chapter 4 TimeWand II Reference

Page 143

Recharging the TimeWand II Your TimeWand II comes equipped with a rechargeable NiCad battery pack. A common pattern of use for the TimeWand II is 8 hours of use followed by 16 hours of recharging. A charge normally lasts for 8 hours of moderate use and may last for several days under light use. The TimeWand II software has a charge management feature that automatically controls the recharge cycle, allowing the batteries to recharge as quickly as possible without overcharging. The TimeWand II estimates how much standard charge it requires by keeping track of the last time it was in the recharger/downloader and the amount of use it has received. You can determine the amount of charge left in your programmed TimeWand II and the approximate time required to bring it to a full charge capacity by pressing the M and left arrow keys simultaneously. When the wand is placed in the recharger/downloader, the batteries are charged at a standard rate for the estimated amount of time and then the charge drops to a trickle charge to maintain full capacity without overcharging the batteries. After the TimeWand II is programmed, it is able to switch automatically to a low-power mode. Before it is programmed, while it is in Monitor Mode and the display reads “TW2 MONITOR 1.75,” it is not able to switch to a low-power mode and therefore drains the batteries in about five hours. When working with an unprogrammed wand, be sure to program it promptly, or remove the battery pack until you are ready to program it. (Note: 1.75 is a version number and may change with future software updates.) To recharge your programmed TimeWand II:

1. Make sure the Recharger/Downloader Station’s Power light is on, and insert the wand into the slot. 2. Press the scan button; the “Power connected” message appears on the display followed by the charge state. Chapter 4 TimeWand II Reference

139

Page 144

3. Let the wand charge until its display shows 100% Charge. If the display shows 100% Charge while in the recharger/ downloader, but shows Low Power when removed from the recharger/downloader, replace the TimeWand II battery pack. When the batteries are at the end of their life, the charge status will display 100% Charge when the wand is in the recharger/downloader; but when the wand is removed from the recharger/downloader, the display will show Low Power. The charge estimate is based on time, NOT on the actual charge capacity of the batteries. If you are not using your TimeWand II for an extended period of time, such as a week or more, remove the battery pack before storing it. This keeps the battery pack from discharging too deeply. Be sure to recharge and reprogram your TimeWand II when you are ready to use it again. In the event that the TimeWand II’s batteries become drained to the point of not operating, follow the procedures described in the detailed troubleshooting section at the end of this chapter and in Appendix H. Replacement battery packs for the TimeWand II are available. Please note the following caution when replacing the TimeWand II battery pack.

Caution: Removing the battery pack from the TimeWand II clears all of the data and the program from the TimeWand II. Be sure to transfer the data from the TimeWand II before replacing the battery pack.

See Appendix G for more information on Automatic Recharge Management and Appendix H for additional information on TimeWand II NiCad batteries.

140

Chapter 4 TimeWand II Reference

Page 145

Using Multiple TimeWand IIs The single Recharger/Downloader Station for TimeWand II charges one wand at a time. If you use more than one TimeWand II, you can purchase a multiple Recharger/Downloader Station which holds up to four TimeWand IIs for data transfer and recharging. The multiple Recharger/Downloader Stations can be connected in series to provide as many recharging positions as are required, all connected to a single computer serial port. Each multiple recharger/downloader in the series must be connected to a power outlet. The limit on the number of multiple recharger/downloaders in a series is normally determined by practical considerations rather than the hardware. Cable length between recharger/downloaders is limited to 50 ft. The connections are shown in Figure 4-1.

Ext

Comp

Ext Comp

Recharger Downloader Station

Recharger Downloader Station

Figure 4-1 Recharger/Downloaders in Series Connect the first multiple recharger/downloader to the computer. See page 16 for instructions. To add additional multiple Recharger/Downloader Stations, connect one end of an interconnect cable (TWC-006) into the “Extension” socket of the multiple recharger/downloader that is connected to the computer. Connect the other end of the interconnect cable into the “Computer” socket on the next multiple recharger/ Chapter 4 TimeWand II Reference

141

Page 146

downloader. Continue the same pattern of connection for each additional unit. Single Recharger/Downloader Stations cannot be connected in series because they do not have an “Extension” socket. However, a single Recharger/Downloader Station can be used at the end of the series, since only the “Computer” socket is needed for the last recharger/downloader station in a series. The series arrangement allows you to transfer data from more than one TimeWand II in a single transfer process. To avoid losing data and other problems when using multiple Recharger/Downloader Stations, you need to be aware of the following cautions:

Caution: Do not attempt to program more than one TimeWand II at a time in a multiple recharger/downloader set up. The TimeWand IIs will not be damaged, but they will not be properly programmed. The data transfer process may take several minutes for each wand. Do not interrupt the process by disconnecting a TimeWand II or aborting the program or you may lose data. The system is designed to avoid data loss, but observing this caution provides added protection.

142

Chapter 4 TimeWand II Reference

Page 147

•

Each of the TimeWand IIs used in a multiple recharger/ downloader arrangement must be configured and have a unique wand ID. Each of these wand IDs should appear in the Wand ID column at the software’s Program and Transfer screens.

•

After all the TimeWand IIs are inserted into the multiple Recharger/Downloader Stations, the data transfer process can be started. The order of data transfer is the order of the wands in the transfer list. However, some circumstances can change the order. When a wand is first inserted into the recharger/downloader, it may not immediately recognize the presence of external power because it is in a state of “sleep.” This is a normal part of its operation. Every 60 seconds, it automatically “wakes up” and checks to see if anything is happening. It recognizes the external power and flashes the message “Power connected,” and then displays the charge status. If data transfer is started before the first wand in the list is awake, there is no response when the computer calls out its ID. The computer then continues down the list looking for a wand that is awake. The order of data transfer is therefore unpredictable. If the order of transferring data from several wands is important, you should insure that the first wand is awake; you can press its scan button before you start the transfer process. The other wands usually wake up while the first is being transferred. If the amount of data in the wands is small, you should wake up all the wands before starting the transfer.

Chapter 4 TimeWand II Reference

143

Page 148

•

Do not remove any of the TimeWand IIs from the recharger/downloaders, quit the TimeWand II Communications & Application Builder program, or shut down your computer until the transfer process is complete. After the transfer is complete, you can view the data by opening the data file.

To avoid losing data, we suggest that you do not interrupt the data transfer process. Do not remove the TimeWand II from the recharger/downloader until this process is completed. However, if you should inadvertently remove a TimeWand II while it is in the process of transferring data, the TimeWand II software displays a message that it was unable to communicate with the wand and then continues to try to transfer the data from all of the other wands in the transfer list. The data in the wand, which was interrupted, will not clear and can be transferred after the other wands have completed their data transfer.

Key Points on Using Multiple TimeWand IIs •

Each TimeWand II must have a unique wand ID.

•

When programming, insert only one TimeWand II in the recharger/downloader at a time.

•

The wand IDs of all TimeWand IIs used with a computer must be listed in the software’s Wand ID column.

•

Data is not cleared from a TimeWand II until all the data is correctly transferred to the computer.

•

Do not interrupt the data transfer process.

144

Chapter 4 TimeWand II Reference

Page 149

Bar Code Scanpad The Bar Code Scanpad is provided with the TimeWand II. It is a card that contains printed Code 3 of 9 bar codes assigned to numbers, letters, and symbols.

*7* *4*

*8* *9* *5* *6*

*A* *B* *d* *e* *g* *h*

*1*

*2* *3*

*J* *k*

*l*

*0* *.*

*o*

*%* * * SPACE

*m* *n* *p* *Q*

*-* *+* */* * * * *

*S* *T* *V* *W*

*U* *X*

1105 NE CIRCLE BLVD. CORVALLIS, OR 97330 541-758-0521

*Y* *Z*

* *

Bar Code Scanpad

*$*

CLEAR

ENTER

*c* *F* *I*

*R*

SPACE

Figure 4-2 Bar Code Scanpad You can scan the individual numbers, letters, and symbols on the scanpad to enter any bar code. This provides another method, besides the TimeWand II keypad, of manually entering characters when you encounter a bar code that is torn, damaged, or otherwise unreadable.

Chapter 4 TimeWand II Reference

145

Page 150

To use the scanpad to enter a bar code, scan each of the characters in proper sequence and then scan ENTER, or press the TimeWand II = key. For example, to enter the bar code number AG-352, scan the letters A and G, then the dash from the other side. Follow with the numbers 3, 5, 2, and then ENTER from either the = key on the wand or the Bar Code Scanpad. The TimeWand II makes a short beep after each character entry and makes a standard good-read beep for ENTER. The standard beep indicates that collective scanpad scans or keypad presses were recorded as a single bar code in the TimeWand II memory. The data is not time stamped for scanpad entries until you scan ENTER or press the TimeWand II = key. If you decide not to make an entry after starting to scan some of the numbers or letters on the scanpad, you can remove these entries by scanning CLEAR before you have scanned ENTER. Individual characters can be erased by pressing the backspace key on the TimeWand II. Any manually keyed characters that have not been entered are also cleared when a bar code of two or more characters is scanned.

146