Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 10

DuraTrax & LaserLite Hardware Manual, pages 21 to 30

Pages 21 to 30 of 94

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Videx DuraTrax and Videx LaserLite

Page 21

LaserLite Laser LaserLite uses a visible-light laser diode to scan bar codes. The laser diode is internally cushioned to protect it from damage. LaserLite can read Code 3 of 9, Interleaved 2 of 5, Codabar, UPC, EAN, and Code 128 bar code symbologies. The LaserLite can read bar codes printed with a variety of printers, including direct thermal and ink-jet printers.

Scanning Bar Codes with a LaserLite To scan a bar code, point the laser towards a bar code and press the scan button. (Note: Verify the lock switch is in the unlocked position before scanning.) You will see a red laser beam. Align the red beam so that the bar code is centered within the beam. The laser beam must cross the entire bar code. Move the LaserLite towards or away from the bar code so that the bar code takes up approximately two-thirds the width of the beam.

Figure 1-6 LaserLite Scanning When the scan button is pressed and the laser beam is emitted, the Power LED lights, indicating laser emission. Following a successful scan, the Valid Scan LED flashes to provide a visual indication of a successful scan. LaserLite also beeps to provide a audio indication of the scan. The laser beam is automatically turned off after scanning a bar code, and is ready to scan again when the scan button is pressed.

DuraTrax and LaserLite Portable Data Collectors

13

Page 22

Key Points • Keep the scan button pressed continually while scanning. • Laser beam must cross the entire bar code. • Align the laser beam so the bar code is centered.

14

DuraTrax and LaserLite Portable Data Collectors

Page 23

Laser Warnings LaserLite incorporates a Class II laser. The visible laser diode has a maximum output of one milliwatt. Laser light can be dangerous to you or others nearby if it is improperly used. Be sure to observe the caution label on top of the LaserLite along with the following cautions: • Do not stare directly into the laser beam. • Do not remove the laser caution label from the LaserLite. • The laser is certified for use with the LaserLite only. Do not connect the laser to any other device.

Figure 1-7 LaserLite Caution Label

DuraTrax and LaserLite Portable Data Collectors

15

Page 24

Communication to the Computer DuraTrax and LaserLite communicate with the computer via an IR link, utilizing IrDA® technology. The DuraTrax and LaserLite’s IR link is the IR transmitter on the end cap. The computer’s IR link may be either a LaserLite DuraTrax Base Station or an external JetEye® PC IR station attached to your computer’s serial port, or a built-in IrDA transceiver addressable as a serial port. DuraTrax and LaserLite establish two-way communication to the host computer using this IR link. To communicate with the computer using a Base Station, insert the DuraTrax or LaserLite into one of the Base Station’s slots (Figure 1-8). A LaserLite DuraTrax Base Station has two slots; either unit can use either slot. The Base Station must be connected to the computer’s serial port with a Videx serial port cable. See pages 17-22 for instructions on connecting the Base Station to the computer. (Note: If the Base Station fails to communicate, reset it by unplugging it from the electric outlet and plugging it back in.)

Figure 1-8 LaserLite DuraTrax Base Stations

16

DuraTrax and LaserLite Portable Data Collectors

Page 25

To communicate with a computer using a JetEye external IR station (Figure 1-9) or a built-in IrDA transceiver, point the DuraTrax or LaserLite’s IR transmitter (located in the end cap) towards the computer’s IR station. Space the data collector approximately four inches from the IR device during communication. (The optimum range for communication is approximately 3 to 12 inches. The range varies depending upon the type of IR station used and the ambient light conditions.)

Figure 1-9 JetEye PC IR Station Use the Application Builder software or one of the download programs for communication. Consult the Application Builder Software manual for specific instructions.

DuraTrax and LaserLite Portable Data Collectors

17

Page 26

LaserLite DuraTrax Base Station The LaserLite DuraTrax Base Station provides communication between the DuraTrax or LaserLite and the computer. The Base Station has three LEDs: Receive, Transmit, and Power. The Receive LED illuminates when the computer is sending information to the data collector. The Transmit LED will illuminate when the data collector is sending information to the computer. The Power LED will illuminate when the Base Station is plugged into an electric power outlet. The Computer port, Power connection, and Extension port are located on the left side of the Base Station (Figure 1-10). The Computer port is where the computer’s serial port cable connects to the Base Station. The Power connection is where the power transformer plugs into the Base Station. The Extension port allows you to connect up to ten Base Stations to a single computer serial port. This allows you to transfer data from more than one data collector during a single transfer process. (Note: The LaserLite DuraTrax Base Station is a communication device, not a recharger; it does not recharge batteries.)

Computer

Extension Power

Figure 1-10 LaserLite DuraTrax Base Station - Side View

18

DuraTrax and LaserLite Portable Data Collectors

Page 27

Connecting the Base Station to Your Computer

The following steps describe how to connect a Base Station to the computer’s serial port. You will need a Base Station and a Videx serial port cable. Please shut down your computer before connecting the Base Station to the serial port.

Figure 1-11 Base Station Connections 1.

Plug the Base Station’s power transformer (Output: 12 VDC 300 mA) into an electric outlet.

2.

Insert the other end of the transformer cable into the Power connection on the side of the Base Station.

DuraTrax and LaserLite Portable Data Collectors

19

Page 28

3.

Verify that the Power light on the Base Station is lit.

4.

Connect the serial port cable’s connector to your computer’s serial port. (Note: A computer’s serial port is always a male connector on a DOS/Windows computer. Pin-outs for the Videx serial port cables are provided in Appendix C.)

5.

Connect the serial port cable’s RJ-11 plug (TWC-001 or TWC-008 for DOS/Windows; TWC-009 for Macintosh) to the Computer port of the Base Station.

6.

The Base Station must be placed at least 3 inches away from your computer and monitor or high levels of electromagnetic interference could hinder communications.

20

DuraTrax and LaserLite Portable Data Collectors

Page 29

Using Multiple Base Stations

The Base Station’s “Extension” port is for connecting more than one Base Station to a computer serial port. To add additional Base Stations, connect one end of an interconnect cable (TWC-006) to the “Extension” port of the Base Station that is connected to the computer. Connect the other end of the interconnect cable into the “Computer” port on the next Base Station. Continue the same pattern of connection for each additional unit, see Figure 1-12.

Figure 1-12 Base Stations in Series The series arrangement allows you to transfer data from up to ten units in a single transfer process.

DuraTrax and LaserLite Portable Data Collectors

21

Page 30

You can connect up to ten Base Stations using a single power transformer. Ten is the maximum number of Base Stations that can be connected to a single computer’s serial port, even if you connect each Base Station to its own power transformer. See Appendix E for information on using multiple data collectors and Base Stations. To avoid any problems when using multiple Base Stations, you need to be aware of the following cautions: •

Each of the data collectors used in a multiple Base Station arrangement must have a unique ID. See Appendix E for information on changing a data collector’s ID and downloading and uploading data with multiple data collectors.

•

When the data transfer process begins, do not remove any of the data collectors from the Base Stations, quit the program, or shut down your computer until the transfer process is complete. Caution: Do not attempt to send an application to more than one unit at a time in a multiple Base Station set up. The data collectors will not be damaged, but they will not be programmed properly. When transferring data from a data collector, do not interrupt the process by removing the unit from its Base Station or aborting the program. The system is designed to avoid data loss, but observing this caution provides added protection.

If you should inadvertently remove a data collector while it is in the process of transferring data, the software displays a message that it was unable to communicate with the unit and then continues to try to transfer the data from all of the other units. The data in the interrupted unit will not clear and can be transferred after the others have completed their data transfer.

22

DuraTrax and LaserLite Portable Data Collectors