Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 10

DuraTrax & LaserLite Hardware Manual, pages 11 to 20

Pages 11 to 20 of 94

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Videx DuraTrax and Videx LaserLite

Page 11

The DuraTrax also features: • Protected read head • Sapphire scan tip • Touch Memory button reader for communicating with Touch Memory buttons (also known as iButtons)

IR Transmitter Valid Scan LED

Scan Tip

Scroll Up

Scan Button

Lock Switch LCD Display Scroll Down Power LED

Touch Memory Button Reader

Figure 1-1 DuraTrax

DuraTrax and LaserLite Portable Data Collectors

3

Page 12

The LaserLite also features: • Visible-light laser diode • Laser internally cushioned

Valid Scan LED

Scroll Up Scan Button

Lock Switch Power LED Laser

LCD Display IR Transmitter Scroll Down

Figure 1-2 LaserLite

Case DuraTrax and LaserLite are made with a sturdy metal case. The case body is made of extruded aluminum, providing strength and durability in a lightweight package. The case is powder coated for a lasting protective finish. The combination of the case design and powder coating provides moisture and dust resistance. DuraTrax measures a compact 6.25 x 1.45 x 1.05 inches and weighs less than nine ounces. LaserLite measures a compact 7.30 x 1.45 (handle)/1.89 (laser) x 1.05 (handle)/1.93 (laser) inches and weighs less than twelve ounces.

4

DuraTrax and LaserLite Portable Data Collectors

Page 13

Display and Buttons DuraTrax and LaserLite have a 2-line by 16-character LCD display and three buttons. The two gray buttons by the display are used to scroll through the data stored in the reader. The large yellow button is the scan button. The scan button is pressed and held while scanning a bar code. DuraTrax and LaserLite have a lock switch, located near the end cap. The lock switch deactivates the unit and prevents unintentional pressing of buttons and unnecessary draining of the batteries while the unit is being stored or transported. Be sure the lock switch is in the unlocked position before attempting to use the DuraTrax or LaserLite.

Memory DuraTrax and LaserLite have 128K (K = 1024 characters) of memory. This is enough storage capacity for over 3,700 5-digit bar code scans (with time and date stamp) to be stored in memory before it is necessary to transfer the data to the computer. More data can be stored by eliminating the time and date stamp from the application.

Clock DuraTrax and LaserLite contain a real-time clock that is set to match the computer’s clock each time the unit is programmed or its data is transferred. For the DuraTrax and LaserLite’s clock to be correct, the date and time on the computer must be set correctly before communicating with the DuraTrax or LaserLite. When a bar code is scanned, or a Touch Memory button is read successfully, the date and time may be recorded along with the entered data. This timekeeping feature makes it possible for you to use a database, spreadsheet, or other program to calculate beginning, ending, and intervals of time from data downloaded from the DuraTrax or LaserLite.

DuraTrax and LaserLite Portable Data Collectors

5

Page 14

Batteries DuraTrax and LaserLite are shipped with 4 AA alkaline batteries. DuraTrax and LaserLite can use either alkaline or nickel-cadmium batteries.

Figure 1-3 DuraTrax/LaserLite Batteries Alkaline batteries require no recharging and typically provide several weeks of use between battery replacements. Exact battery life depends upon actual use; a fresh set of alkaline batteries will provide approximately 2,000 milliampere hours (mAh) capacity, which can provide up to 100,000 or more scans from one set of alkaline batteries. If you choose to use nickel-cadmium (NiCad) batteries, you will need to remove them from the unit before you recharge them. You must recharge the NiCad batteries in an external battery recharger. The LaserLite DuraTrax Base Station does NOT recharge batteries. (Note: The DuraTrax/LaserLite lithium back-up battery will maintain the data and program while you recharge the NiCad batteries.) NiCad batteries rated at 500 mAh, which can provide enough power for up to 25,000 scans from one set of batteries; NiCad batteries rated at 1200 mAh, should provide enough power for approximately 50,000 scans from one set of batteries. 6

DuraTrax and LaserLite Portable Data Collectors

Page 15

The following chart shows the current draw of a DuraTrax or LaserLite during operations: Operation Sleep Idle (Display on) Processing Button read Contact on Laser on

Approximate Current Draw 1 mA 10 mA 20 mA 21 mA 80 mA 100 mA

DuraTrax and LaserLite have a rechargeable lithium back-up battery that maintains the program and data while the batteries are being replaced. The battery cutoff voltage is approximately 4.0 volts. If the batteries drop below 4 volts, the unit will stop operating until the batteries are replaced. If you do not immediately replace the AA batteries, the lithium back-up battery will maintain the program and data for up to five days. The DuraTrax/LaserLite AA batteries recharge the lithium back-up battery. To keep the lithium back-up battery at full charge, the DuraTrax and LaserLite should always be stored with AA batteries installed.

DuraTrax and LaserLite Portable Data Collectors

7

Page 16

Replacing the DuraTrax and LaserLite Batteries You will need four (4) new AA alkaline or nickel-cadmium batteries. The following steps guide you through replacing the batteries: 1.

Place the DuraTrax or LaserLite’s lock switch in the locked position (switch towards picture of lock).

2.

Remove the battery end cap by loosening the end cap screw and pulling out the end cap. Place the end cap in a safe place for later reassembly.

3.

Remove the four old batteries and replace with four new AA batteries. Be sure the batteries are installed correctly. (Note: The correct battery polarity is etched on the data collector’s case.)

4.

Reinstall the end cap and tighten the end cap screw.

5.

Flip the lock switch back to the unlocked position and your DuraTrax or LaserLite is now ready to use.

8

DuraTrax and LaserLite Portable Data Collectors

Page 17

Battery Information and Warnings Videx recommends using high-quality AA alkaline or nickel-cadmium batteries. Substitution of batteries other than those recommended by Videx could alter the operating life of your DuraTrax and LaserLite. Note: The following warnings are very important: •

Always keep AA batteries installed in the DuraTrax/LaserLite. This practice will keep the rechargeable lithium back-up battery fully charged.

•

Do install the batteries correctly, or you may damage your DuraTrax or LaserLite.

•

Do not mix battery types (i.e., nickel-cadmium and alkaline).

•

Do not mix new and used batteries. Replace all batteries for optimum battery performance.

•

Do not dispose of batteries in fire.

DuraTrax and LaserLite Portable Data Collectors

9

Page 18

DuraTrax Read Head DuraTrax has a 655 nm visible light read head. A 655 nm read head is in the visible light range and can read bar codes printed with a variety of printers, including direct thermal and thermal transfer. The 655 nm read head can also read bar codes where contrast has been a problem, such as bar codes printed on an ink-jet printer. The read head is protected by a sapphire scan tip which keeps the read head clean and protects it from damage.

Scanning Bar Codes with a DuraTrax To scan a bar code with a DuraTrax, press and hold the scan button while sweeping the scan tip across a bar code. (Note: Verify the lock switch is in the unlocked position before scanning.)

A

Place the scan tip in the white area about 1/4 inch preceding the bar code.

B

While holding down the scan button, pass the scan tip across the bar code quickly and steadily.

Be sure to start your scan in the white area in front of the bar code. This is the “quiet zone” and allows the DuraTrax to correctly recognize the first bars of the bar code. When scanning the bar code, use a quick motion. We have found that for most bar codes you cannot scan too fast for a DuraTrax, but it is possible to scan too slowly. Use about the same speed you would use to strike a match. Experiment to find the speed and angle that works best for you. A successful scan is verified by both a flash of the valid scan LED and an audible tone. DuraTrax can read Code 3 of 9, Interleaved 2 of 5, EAN, UPC, Codabar, and Code 128 bar code symbologies. 10

DuraTrax and LaserLite Portable Data Collectors

Page 19

Key Points • Keep the scan button pressed continually while scanning. • Scan tip must contact the bar code. • Begin scan in the white area preceding bar code. • Use a quick scanning motion, like striking a match. • To prolong battery life, release the scan button between scans.

Reading Buttons with a DuraTrax To read a button, place the DuraTrax Touch Memory button reader over a Touch Memory button - the round rim of the button helps guide the DuraTrax for easy alignment. With a momentary touch, DuraTrax reads the button and stores the data in memory. DuraTrax emits an audible beep and the valid scan LED flashes with each successful read. (Note: Verify the lock switch is in the unlocked position before reading a button.)

Figure 1-4 Reading a Touch Memory Button with DuraTrax DuraTrax can read the ID from DS1990, DS1991, DS1992, DS1993, DS1994, and other Touch Memory buttons.

DuraTrax and LaserLite Portable Data Collectors

11

Page 20

Touch Memory Buttons

A Touch Memory button (also known as an iButton) is a memory chip housed in a stainless steel container. The stainless steel container protects the memory chip and also provides an electrical path for communication. The top of the button is connected to the enclosed memory chip circuit, and the bottom and sides of the button provide a signal ground. When the DuraTrax Touch Memory button reader touches a button, the top and the sides of the button are connected and an electrical path is established. Through this path, data is transferred at up to 16,000 bits per second. All Touch Memory buttons contain a serial number that is programmed into the button at the factory. The serial number is unalterable and along with the family code, uniquely identifies each button. A DS1990 button is a read-only button. DS1991, DS1992, DS1993, and DS1994 buttons are read/write buttons. Touch Memory buttons can be attached to virtually anything by using an adhesive backing, a mounting bracket, or a key chain.

Figure 1-5 Touch Memory Buttons

12

DuraTrax and LaserLite Portable Data Collectors