The text of a manual · part 23 of 25
Application Builder for DuraTrax/LaserLite/LaserLite Pro/LaserLite Mx, for Windows Computers, pages 221 to 230
Pages 221 to 230 of 245
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Videx DuraTrax, Videx LaserLite, Videx LaserLite Mx and Videx LaserLite Pro
Page 221
Inventry.abd Application Bar Codes Location Bar Codes:
*D14*
*D17*
*D14*
*D17*
Item Bar Codes:
*PC12* Fax Machine
*PC14* Printer
*PC24* Projector Misc. Bar Codes:
*MEM* Memory
*BATT* Battery
*
*
DELETE LAST SCAN
Appendix A Sample Applications
213
Page 222
214
Appendix A Sample Applications
Page 223
Appendix B Resetting the Data Collector In the unlikely event that your data collector locks up and does not recover after sitting for two to three minutes, you must manually reset the unit and use Vxcom to resend the operating system software to the data collector. The actual names of the operating system files will change as new versions of the software are released. The operating system software filename will always begin with Trax for a DuraTrax, with Lite for a LaserLite, with Pro for a LaserLite Pro, and with Lmx for a LaserLite Mx. The operating system software filename for all three units will always end with a .OS extension. (For example, Trax125a.OS for a DuraTrax, Lite125a.OS for a LaserLite, Pro125a.OS for a LaserLite Pro, and Lmx123a.OS for a LaserLite Mx.) To manually reset the unit: 1) Remove the battery end cap. 2) Hold the scan button down while replacing the battery end cap. 3) The unit will beep three times, indicating a successful reset. 4) The DuraTrax or LaserLite will show VX1 Monitor 1.07 on the first line of the display, and Ready, bps=9600 on the second line. The LaserLite Pro will show VX1 Monitor 1.11 or 1.34 on the first line, and Ready, bps=9600 on the second line. The LaserLite Mx will show VX1 Monitor 1.33 or 1.34 on the first line, and Ready, bps=9600 on the second line. 5) Drag the operating system file onto the Vxcom icon to resend the operating system software to the unit. Note: If you have not previously used Vxcom to transfer the data file, you will first need to set the Vxcom parameters. See Steps 26–31 on pages 21–23 for instructions. See the Developer’s Reference Manual for complete information on Vxcom.
Appendix B Resetting the Data Collector
215
Page 224
Notes:
216
Appendix B Resetting the Data Collector
Page 225
Appendix C Using Multiple Data Collectors and Base Stations Up to ten Videx Base Stations can be connected in series to a single serial port; this allows the user to transfer data from multiple data collectors in a single transfer process. If you are using LaserLite Pro or LaserLite Mx data collectors, you can transfer data from up to ten units at a time; and if you are using DuraTrax or LaserLite data collectors, you can transfer data from up to twenty units at a time.
Connecting the Base Stations To connect multiple Base Stations: 1) Connect the first Base Station to the computer’s serial port: a) Plug the Base Station’s transformer into an electric outlet and connect the other end into the Base Station’s Power connection. b) Use the serial port cable to connect the computer’s serial port to the Base Station’s Computer port. c) The Base Station should be placed at least 3 inches away from the computer and monitor. 2) To add additional Base Stations: a) Use an interconnect cable (TWC-006) to connect the Extension port of the first Base Station to the Computer port on the second Base Station. See Figure C-1. b) Continue the same pattern of connection for each additional unit.
Appendix C Using Multiple Data Collectors and Base Stations
217
Page 226
Figure C-1 Base Stations in Series Exception to connecting ten Base Stations to a single serial port: If you are using the charge feature on the LaserLite Pro/Mx Base Station and only one power transformer, then you can only connect up to three Base Stations to a single serial port. However, even if using the charge feature, you can still connect up to ten Base Stations if each one is plugged into its own power transformer.
Changing a Data Collector’s ID When using multiple Base Stations, you must give each data collector a unique ID; this allows the computer to access each data collector and verify that it has transferred the data from each one. To assign an ID, you must first create a commands text file, then click and drag the file onto the Vxcom icon. Vxcom then uses the commands file to unlock the unit and change the ID. (For complete information on Vxcom and using a commands text file, see Chapter 1 of the Developer’s Reference Manual.)
218
Appendix C Using Multiple Data Collectors and Base Stations
Page 227
During normal operation, a unit is given an ID of ten zeros. To change the ID, you must create a text file consisting of the following three command lines: 1) An I command, followed by a space, followed by ten zeros to unlock the unit. 2) A C command, followed by a space, followed by the new ID. 3) An L command to relock the unit. I 0000000000 C new ID#
L
Sends an UNLOCK command to the data collector. (Note: Ten zeros will unlock any data collector.) Changes the unit’s ID to the given ID. The ID can be any alphanumeric combination of up to ten characters in length. For example, if you want an ID of 1, this line should be C 1; if you want an ID of BuildingD, this line should be C BuildingD; if you want an ID of 123#_AB, this line should be C 123#_AB, and so on. Sends a LOCK command and puts the data collector to sleep. When the unit is awakened with a keypress, it immediately runs the current application.
Appendix C Using Multiple Data Collectors and Base Stations
219
Page 228
For example, to change a data collector’s ID to 12345: 1. Use your word processing program to create a text file containing the following three lines: I 0000000000 C 12345 L 2. Save the file as a text file and quit the program. (Note: The text file must have a .txt extension.) 3. Place a data collector into the Base Station slot. IMPORTANT: When you are sending a file to a data collector, it must be the ONLY data collector attached to the computer. 4. Click and drag the text file you created onto the Vxcom icon. 5. Vxcom executes the commands listed in the text file; it unlocks the unit, changes the ID to what is listed after the C command (in this case, 12345), and then relocks the unit. 6. Remove your data collector from the Base Station slot; your data collector is ready to use.
220
Appendix C Using Multiple Data Collectors and Base Stations
Page 229
To continue changing other data collectors’ IDs: 1. Reopen the text file. 2. Change the ID listed after the C command by selecting 12345 and typing in a new ID. (Note: There must be a space character between the C and the ID.) 3. Save and close the text file. Remember, the text file must have a .txt extension. 4. Insert a data collector into the Base Station slot. 5. Click and drag the edited text file to the Vxcom icon. 6. Vxcom executes the commands listed in the text file; it unlocks the unit, changes its ID to what is listed after the C command, and then relocks the unit. 7. Continue these same steps until you have assigned a unique ID to each of your units. Note: Keep a list of the IDs you are using to identify your data collectors. You will use this list in the next section, Transferring Data from Multiple Data Collectors.
Appendix C Using Multiple Data Collectors and Base Stations
221
Page 230
Transferring Data from Multiple Data Collectors To transfer data from a group of data collectors in one transfer process, you must: 1. Create a commands text file that uses the FOREVER, FOREACH, or FORALL looping commands to transfer the data from the data collectors. (Note: The commands file must have a .txt extension. For complete information on using commands files, see Chapter 1 of the Developer’s Reference Manual.) 2. Insert all the data collectors into their Base Stations. 3. Click and drag the commands text file onto the Vxcom icon. The three looping commands provide transfer methods for three different situations. The FOREVER loop is useful if you have a computer dedicated to transferring the data from the data collectors. The FOREACH loop is useful if you will be transferring the data from only a portion of your data collectors. The FORALL loop is useful if you require that all of the data collectors be transferred during the process. The following table describes the looping commands: FOREVER
For use with a computer that is dedicated to transferring data. This loop will transfer the data from any data collector it locates. This loop attempts to execute commands within a loop indefinitely.
FOREACH
This loop will search for each data collector in the list of IDs. If it locates the data collector with the ID, it executes the commands within the loop once; if it does not locate the data collector with the ID, it goes on to the next ID. This loop attempts to execute commands within a loop once for each ID listed.
FORALL
This loop will look for each listed data collector’s ID until it has located and transferred the data from each ID in the list. This loop attempts to execute commands within a loop indefinitely, until all listed IDs have been located.
222
Appendix C Using Multiple Data Collectors and Base Stations