The text of a manual · part 13 of 25
Application Builder for DuraTrax/LaserLite/LaserLite Pro/LaserLite Mx, for Windows Computers, pages 121 to 130
Pages 121 to 130 of 245
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Videx DuraTrax, Videx LaserLite, Videx LaserLite Mx and Videx LaserLite Pro
Page 121
34. Select Add time to record from the Action description pop-up menu (Figure 3-38).
Figure 3-38 Actions Property - Add Time to Record
Chapter 3 Building an Application with Application Builder
113
Page 122
35. Click Add (Figure 3-39) to add the Add time to record action to the action list (Figure 3-40).
Figure 3-39 Actions Property - Add Action to Action List
Figure 3-40 Actions Property - Action Added to Action List
114
Chapter 3 Building an Application with Application Builder
Page 123
36. Select Add date to record from the Action description pop-up menu (Figure 3-41).
Figure 3-41 Actions Property - Add Date to Record
Chapter 3 Building an Application with Application Builder
115
Page 124
37. Click Add (Figure 3-42) to add the Add date to record action to the action list (Figure 3-43).
Figure 3-42 Actions Property - Add Action to Action List
Figure 3-43 Actions Property - Action Added to Action List
116
Chapter 3 Building an Application with Application Builder
Page 125
38. The Summary window for the “Location” Handler is shown in Figure 3-44.
Figure 3-44 Summary Window - “Location” Handler “Location” Handler Summary Window: Looping - Can start a loop; cannot end a loop. Matching - Entry must start with the letter D. Device - Must be entered by keypad, laser, contact, or touch. Symbology - Any of the following bar code symbologies are acceptable: Code 3 of 9, Interleaved 2 of 5, Codabar, UPC, EAN, Code 128. Actions - When the input matches the above requirements, the data collector will perform these actions: Beep, Add input to record, Add time to record, and Add date to record. Detour - This Input Handler is not a Detour Handler. We will use these settings for the “Location” Handler in this example. Next, we will set the properties for the “Status” Handler. We will use the property defaults, except for the Looping and Matching properties.
Chapter 3 Building an Application with Application Builder
117
Page 126
39. Click the “Status” Handler to select it (Figure 3-45).
Figure 3-45 Select “Status” Handler For the “Status” Handler we will change the Looping and Matching properties. 40. Select Looping from the Properties window Category list (Figure 3-46). Since we only want a Status entry if a Location has been entered, we will not allow the “Status” Handler to begin a loop; this will require that a Location entry be made before a Status entry can be made.
Figure 3-46 “Status” Handler - Looping Property
118
Chapter 3 Building an Application with Application Builder
Page 127
41. Click the Can start loop check box to deselect the option (Figure 3-47). (A checkmark should not appear in the box.)
Figure 3-47 “Status” Handler - Looping (Cannot Start Loop - Can End Loop) 42. Select Matching from the Properties window (Figure 3-48).
Figure 3-48 “Status” Handler - Matching Property
Chapter 3 Building an Application with Application Builder
119
Page 128
43. The unique match criterion that we have selected for the Status bar codes is they start with the letter S. So, we will use starts with S for our “Status” Handler match criterion. Choose starts with from the Matching property pop-up menu (Figure 3-49).
Figure 3-49 Matching Property - Starts With
120
Chapter 3 Building an Application with Application Builder
Page 129
44. Click in the edit box and enter an S (Figure 3-50). Any entry that starts with an S is now an acceptable entry for the “Status” Handler.
Figure 3-50 Matching Property - Starts With S 45. The Summary window for the “Status” Handler is shown in Figure 3-51.
Figure 3-51 Summary Window - “Status” Handler
Chapter 3 Building an Application with Application Builder
121
Page 130
“Status” Handler Summary Window: Looping - Cannot start a loop; can end a loop. Matching - Entry must start with the letter S. Device - Must be entered by keypad, laser, contact, or touch. Symbology - Any of the following bar code symbologies are acceptable: Code 3 of 9, Interleaved 2 of 5, Codabar, UPC, EAN, Code 128. Actions - When the input matches the above requirements, the data collector will perform these actions: Beep and Add input to record. Detour - This Input Handler is not a Detour Handler.
122
Chapter 3 Building an Application with Application Builder